412355A-NIST Teledyne FLIR


412300a_412355adata.pdf Виробник: Teledyne FLIR
Current and Voltage Calibrator
товар відсутній

Відгуки про товар
Написати відгук

Технічний опис 412355A-NIST Teledyne FLIR

Category: Calibrators, Description: Meter: calibrator; voltage,current; VDC: 0÷20V; I DC: 0÷50mA, Dimensions: 96x118x45mm, Operating temperature: 5...40°C, Measurement memory: 5, Standard equipment: calibration certificate NIST; calibration lead; case; power supply, Measuring instrument features: automatic power-off; low battery indicator; measures and sources current signals; measures and sources voltage signals; overflow indication, Type of meter: calibrator, Kind of calibrator: current; voltage, Current source accuracy: ±(0,075% + 1 digit) or ±3 digits, whichever is greater, Voltage source accuracy: ±(0,075% + 1 digit) or ±3 digits, whichever is greater, Power supply: battery 6F22 9V x1, Kind of display used: LCD, DC current measuring range: 0...50mA, DC voltage measuring range: 0...20V, Current source: 0...24mA, Voltage source: 0...20V, Display parameters: (9999), DC voltage measuring accuracy: ±(0.075% + 1 digit); ±3 digit, DC current measuring accuracy: ±(0.075% + 1 digit); ±3 digit, кількість в упаковці: 1 шт.

Інші пропозиції 412355A-NIST

Фото Назва Виробник Інформація Доступність
Ціна без ПДВ
412355A-NIST 412355A-NIST Виробник : EXTECH 412355A_UM.pdf Category: Calibrators
Description: Meter: calibrator; voltage,current; VDC: 0÷20V; I DC: 0÷50mA
Dimensions: 96x118x45mm
Operating temperature: 5...40°C
Measurement memory: 5
Standard equipment: calibration certificate NIST; calibration lead; case; power supply
Measuring instrument features: automatic power-off; low battery indicator; measures and sources current signals; measures and sources voltage signals; overflow indication
Type of meter: calibrator
Kind of calibrator: current; voltage
Current source accuracy: ±(0,075% + 1 digit) or ±3 digits, whichever is greater
Voltage source accuracy: ±(0,075% + 1 digit) or ±3 digits, whichever is greater
Power supply: battery 6F22 9V x1
Kind of display used: LCD
DC current measuring range: 0...50mA
DC voltage measuring range: 0...20V
Current source: 0...24mA
Voltage source: 0...20V
Display parameters: (9999)
DC voltage measuring accuracy: ±(0.075% + 1 digit); ±3 digit
DC current measuring accuracy: ±(0.075% + 1 digit); ±3 digit
кількість в упаковці: 1 шт
товар відсутній
412355A-NIST Виробник : FLIR Extech 412300A_412355Adata.pdf Description: CALIBRATOR W/ NIST 412355A
товар відсутній
412355A-NIST 412355A-NIST Виробник : EXTECH 412355A_UM.pdf Category: Calibrators
Description: Meter: calibrator; voltage,current; VDC: 0÷20V; I DC: 0÷50mA
Dimensions: 96x118x45mm
Operating temperature: 5...40°C
Measurement memory: 5
Standard equipment: calibration certificate NIST; calibration lead; case; power supply
Measuring instrument features: automatic power-off; low battery indicator; measures and sources current signals; measures and sources voltage signals; overflow indication
Type of meter: calibrator
Kind of calibrator: current; voltage
Current source accuracy: ±(0,075% + 1 digit) or ±3 digits, whichever is greater
Voltage source accuracy: ±(0,075% + 1 digit) or ±3 digits, whichever is greater
Power supply: battery 6F22 9V x1
Kind of display used: LCD
DC current measuring range: 0...50mA
DC voltage measuring range: 0...20V
Current source: 0...24mA
Voltage source: 0...20V
Display parameters: (9999)
DC voltage measuring accuracy: ±(0.075% + 1 digit); ±3 digit
DC current measuring accuracy: ±(0.075% + 1 digit); ±3 digit
товар відсутній