| Фото | Назва | Виробник | Інформація | Доступність | Ціна без ПДВ | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
FLUKE TI-SBP3 | FLUKE |
Description: FLUKE - FLUKE TI-SBP3 - Akku, Fluke Ti125/Ti110/Ti100, Lithium-IonentariffCode: 85076000 productTraceability: No rohsCompliant: NA Batterie-/Akkutechnologie: Lithium-Ionen euEccn: NLR hazardous: true hazardCode: 3480 rohsPhthalatesCompliant: NA Zur Verwendung mit: Wärmebildkameras Fluke Ti125, Ti110 für industrielle/gewerbliche Anwendungen & universell einsetzbare Wärmebildkameras Fluke Ti100 usEccn: EAR99 Produktpalette: - SVHC: No SVHC (15-Jun-2015) |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
| FLUKE TI-VISOR2 | Fluke | Glare Protection |
на замовлення 2 шт: термін постачання 21-31 дні (днів) |
|
|||||||
|
FLUKE TL175 | FLUKE |
Description: FLUKE - FLUKE TL175 - Messleitungssatz, Tastkopfspitze, 4mm-Bananenstecker, abgewinkelt, mit Kragen, 1 kV, 10 A tariffCode: 90309000 rohsCompliant: Y-EX hazardous: false rohsPhthalatesCompliant: TBA Anschlusslänge - metrisch: 1.2m Anzahl der Messleitungen: 2 Anschlusslänge - imperial: 3.94ft usEccn: EAR99 Nennstrom: 10A Teststecker B: 4mm-Bananenstecker, abgewinkelt, mit Kragen euEccn: NLR Isolatorfarbe: Schwarz, Rot Produktpalette: - productTraceability: No Nennspannung: 1kV Teststecker A: Tastkopfspitze SVHC: No SVHC (12-Jan-2017) |
на замовлення 213 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
|
FLUKE TL225-1 | FLUKE |
Description: FLUKE - FLUKE TL225-1 - Kit, Messleitungen TL224, Streuspannungsadapter SV225, SureGrip-Messfühlersatz TP220, TaschetariffCode: 90303100 productTraceability: No rohsCompliant: Y-EX Lieferumfang des Kits: Messleitungssatz (TL224), Streuspannungsadapter (SV225), Satz SureGrip-Messfühler (TP220), Zubehörtasche (C75) euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: EAR99 Produktpalette: - SVHC: No SVHC (15-Jun-2015) |
на замовлення 5 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
|
FLUKE TL71-1 | FLUKE |
Description: FLUKE - FLUKE TL71-1 - Messleitungssatz, Tastkopfspitze, 4mm-Bananenstecker, abgewinkelt, mit Kragen, 1 kV, 10 AtariffCode: 90309000 rohsCompliant: Y-EX hazardous: false rohsPhthalatesCompliant: TBA Anschlusslänge - metrisch: 1.2m Anzahl der Messleitungen: 2 Anschlusslänge - imperial: 4ft usEccn: EAR99 Nennstrom: 10A Teststecker B: 4mm-Bananenstecker, abgewinkelt, mit Kragen euEccn: NLR Isolatorfarbe: Schwarz, Rot Produktpalette: - productTraceability: No Nennspannung: 1kV Teststecker A: Tastkopfspitze SVHC: No SVHC (23-Jan-2024) |
на замовлення 49 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
| FLUKE TL71-1 | Fluke | Test Lead Set Premium Dmm |
на замовлення 3 шт: термін постачання 21-31 дні (днів) |
|
|||||||
| FLUKE TL75-1 | Fluke | Hard Point TM Test Lead Set |
на замовлення 2 шт: термін постачання 21-31 дні (днів) |
Мінімальне замовлення: 2 шт В кошику од. на суму грн. | |||||||
|
FLUKE TLK281-1 | FLUKE |
Description: FLUKE - FLUKE TLK281-1 - Messleitungskit, Kfz, Einstechklemmen, Messleitungen, Tastköpfe, Krokodilklemmen, Tasche tariffCode: 90303100 productTraceability: No rohsCompliant: Y-EX euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: EAR99 Produktpalette: - SVHC: To Be Advised |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
|
FLUKE TP220-1 | FLUKE |
Description: FLUKE - FLUKE TP220-1 - Tastkopfsatz, rote & schwarze industrielle Tastköpfe, 12mm-Edelstahlspitze, flexibler Fingerschutz tariffCode: 90309000 productTraceability: No rohsCompliant: Y-EX Lieferumfang des Kits: 1 Paar rote & schwarze industrielle Messspitzen, 12mm-Edelstahlspitze, flexibler Fingerschutz euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: EAR99 Produktpalette: - |
на замовлення 12 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
| FLUKE TPAK TOOLPAK | Fluke | FLUKE TPAK TOOLPAK |
на замовлення 3 шт: термін постачання 21-31 дні (днів) |
|
|||||||
|
FLUKE UA120 | FLUKE |
Description: FLUKE - FLUKE UA120 - Messzubehör, USB-Steckverbinder-Adapter tariffCode: 85176200 Art des Zubehörs: USB-Steckverbinder-Adapter productTraceability: No rohsCompliant: YES euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: EAR99 Produktpalette: - SVHC: No SVHC (15-Jun-2015) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
| FLUKE-110 | Fluke | FLUKE-110 |
на замовлення 2 шт: термін постачання 21-31 дні (днів) |
|
|||||||
| FLUKE-113 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V Conform to the norm: CAT III 600V; EN 61010 Type of meter: digital multimeter Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC voltage measuring range: 1mV...6V; 60V; 600V Diode test: 1.2mA @2.7V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Dimensions (W x H x D): 84x167x46mm Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Weight with battery: 404g Standard equipment: FLK-TL75 test leads Display parameters: 3,75 digit (6000) Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Measurement: capacitance; DC voltage; resistance Continuity test: acoustic indication; <20Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Kind of display used: LCD |
на замовлення 24 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-114 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Manufacturer series: Fluke 110 Battery/ rechargeable battery: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Power supply: battery 6LR61 9V x1 DC voltage measuring accuracy: ±(0.5% + 2 digit) Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222 Related items: POM-5673B; POM-5900A/POM; POM-7519A Pollution degree: 2 Kind of display used: LCD Continuity test: acoustic indication; <20Ω True effective value measurement: True RMS AC DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Weight with battery: 550g Bargraph: 33 segm. 32x/s AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Dimensions (W x H x D): 84x167x46mm Conform to the norm: CAT III 600V; EN 61010 Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Type of meter: digital multimeter Measurement: AC voltage; DC voltage; resistance Display parameters: 3,75 digit (6000) |
на замовлення 20 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-115 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Display parameters: 3,75 digit (6000) AC current measuring range: 1mA...6A; 10A; (20A <30s) Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Battery/ rechargeable battery: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Power supply: battery 6LR61 9V x1 Manufacturer series: Fluke 110 DC voltage measuring accuracy: ±(0.5% + 2 digit) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Related items: POM-5543B; POM-6275; POM-6343 DC current measuring accuracy: ±(1% + 3 digit) Pollution degree: 2 Kind of display used: LCD Continuity test: acoustic indication; <20Ω True effective value measurement: True RMS AC DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC current measuring accuracy: ±(1.5% + 3 digit) Weight with battery: 550g Diode test: 1.2mA @2.7V Bargraph: 33 segm. 32x/s Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring accuracy: ±(0.1%+2 digit) Dimensions (W x H x D): 84x167x46mm Conform to the norm: CAT III 600V; EN 61010 Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Type of meter: digital multimeter Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance |
на замовлення 104 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-116 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) Temperature measuring range: -40...400°C Temperature measurement accuracy: ±(0.1% + 2 digit) Power supply: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Standard equipment: FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Pollution degree: 2 Continuity test: acoustic indication; <20Ω True effective value measurement: True RMS AC DC current measuring range: 0.1...600µA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC current measuring accuracy: ±(1.5% + 3 digit) Weight with battery: 550g Diode test: 1.2mA @2.7V Bargraph: 33 segm. 32x/s Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring accuracy: ±(0.1%+2 digit) Dimensions (W x H x D): 84x167x46mm Conform to the norm: CAT III 600V; EN 61010 Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Measuring instruments application: air conditioning; heating industry; ventilation AC current measuring range: 0.1...600µA Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Battery/ rechargeable battery: battery 6LR61 9V x1 Capacitance measuring accuracy: ±(1.9%+ 2 digit) Manufacturer series: Fluke 110 DC voltage measuring accuracy: ±(0.5% + 2 digit) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 DC current measuring accuracy: ±(1% + 2 digit) |
на замовлення 20 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-116/323 KIT | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Type of measuring kit: multimeters Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 |
на замовлення 5 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-116/323-KIT | Fluke | FLUKE-116/323-KIT |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
|||||||
| FLUKE-117 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Display parameters: 3,75 digit (6000) AC current measuring range: 1mA...6A; 10A; (20A <30s) Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Battery/ rechargeable battery: battery 6LR61 9V x1 Capacitance measuring accuracy: ±(1.9%+ 2 digit) Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Power supply: battery 6LR61 9V x1 Manufacturer series: Fluke 110 DC voltage measuring accuracy: ±(0.5% + 2 digit) Optional equipment: FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Related items: POM-5673B; POM-5900A/POM; POM-7519A DC current measuring accuracy: ±(1% + 3 digit) Pollution degree: 2 Kind of display used: LCD Continuity test: acoustic indication; <20Ω True effective value measurement: True RMS AC DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC current measuring accuracy: ±(1.5% + 3 digit) Weight with battery: 550g Diode test: 1.2mA @2.7V Bargraph: 33 segm. 32x/s Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring accuracy: ±(0.1%+2 digit) Dimensions (W x H x D): 84x167x46mm Conform to the norm: CAT III 600V; EN 61010 Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance |
на замовлення 71 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-123B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Dimensions: 259x132x55mm Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Manufacturer series: FLUKE 120B DC voltage measuring accuracy: ±(0.5% + 5 digit) Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Type of oscilloscope: scopemeter Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Related items: POM-72941; POM-72942 Kind of display used: colour; LCD TFT 5,7" Continuity test: acoustic indication DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Sampling: 40Msps Display resolution: 640x480 Diode test: 0.5mA @2.8V Connectors for the country: Europe AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Band: 20MHz Time base: 20n...60s/div Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Resistance measuring accuracy: ±(0.6%+5 digit) Additional functions: multimeter Number of channels: 2 IP rating: IP51 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance |
на замовлення 2 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-123B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Type of oscilloscope: scopemeter Band: 20MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 20n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe Related items: POM-72941; POM-72942 |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
| FLUKE-124B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Dimensions: 259x132x55mm Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Manufacturer series: FLUKE 120B DC voltage measuring accuracy: ±(0.5% + 5 digit) Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Type of oscilloscope: scopemeter Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Related items: POM-72941; POM-72942 Kind of display used: colour; LCD TFT 5,7" Continuity test: acoustic indication DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Sampling: 40Msps Display resolution: 640x480 Diode test: 0.5mA @2.8V Connectors for the country: Europe AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Band: 40MHz Time base: 10n...60s/div Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Resistance measuring accuracy: ±(0.6%+5 digit) Additional functions: multimeter Number of channels: 2 IP rating: IP51 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance |
на замовлення 2 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-124B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe Related items: POM-72941; POM-72942 |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
| FLUKE-125B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe Related items: POM-72941; POM-72942 |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
| FLUKE-125B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe |
на замовлення 1 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1503 | Fluke |
Insulation Resistance Tester |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
|||||||
| FLUKE-1503 | Fluke |
Insulation Resistance Tester |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
|||||||
| FLUKE-1503 | FLUKE |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Body dimensions: 203x100x50mm IP rating: IP40 Measurement: AC voltage; DC voltage; insulation resistance; resistance Automatic discharging capacitance: max. 1µF Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Capacitance discharge time: <0.5s Bandwidth for AC voltage measurements: 50...400Hz Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe Power supply: battery LR6 AA 1,5V x4 DC voltage measuring accuracy: ±(2% + 3 digit) Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter Related items: POM-5674C; POM-5907A; POM-6041B Kind of display used: LCD Continuity test: acoustic indication DC voltage measuring range: 100mV...600V Open circuit test voltage: 4...8V Weight with battery: 550g AC voltage measuring range: 100mV...600V Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ Insulation resistance measuring accuracy: ±(2% + 5digit) Test voltage: 500V DC; 1kV DC Conform to the norm: CAT IV 600V; EN 61010 Resistance measuring accuracy: ±(1.5%+3 digit) Illumination: yes AC voltage measuring accuracy: ±(2% + 3 digit) Type of meter: insulation resistance |
на замовлення 11 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1507 | Fluke |
Insulation Resistance Tester |
на замовлення 3 шт: термін постачання 21-31 дні (днів) |
|
|||||||
| FLUKE-1507 | FLUKE |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Body dimensions: 203x100x50mm Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Capacitance discharge time: <0.5s Bandwidth for AC voltage measurements: 50...400Hz Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection Power supply: battery LR6 AA 1,5V x4 DC voltage measuring accuracy: ±(2% + 3 digit) Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter Related items: POM-5674C; POM-5907A; POM-6041B Kind of display used: LCD Continuity test: acoustic indication DC voltage measuring range: 100mV...600V Open circuit test voltage: 4...8V Weight with battery: 550g AC voltage measuring range: 100mV...600V Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ Insulation resistance measuring accuracy: ±(1.5% + 5digit) Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC Conform to the norm: CAT IV 600V; EN 61010 Resistance measuring accuracy: ±(1.5%+3 digit) Illumination: yes AC voltage measuring accuracy: ±(2% + 3 digit) Type of meter: insulation resistance IP rating: IP40 Measurement: AC voltage; DC voltage; insulation resistance; resistance Automatic discharging capacitance: max. 1µF |
на замовлення 31 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1577 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Type of meter: digital multimeter Optional equipment: FLK-C25 soft cover IP rating: IP40 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Dimensions (W x H x D): 100x203x50mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.2% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(1.2%+2 digit) AC current measuring accuracy: ±(2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Test voltage: 500V; 1kV Weight with battery: 550g Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance |
на замовлення 2 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1587 FC | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Display parameters: (6000) AC current measuring range: 10µA...60mA; 400mA Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Temperature measurement resolution: 0.1°C Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Capacitance measuring accuracy: ±(1.2%+ 2 digit) Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Power supply: battery LR6 AA 1,5V x4 DC voltage measuring accuracy: ±(0.09% + 2 digit) Optional equipment: FLK-C25 soft cover Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B DC current measuring accuracy: ±(0.2% + 2 digit) Kind of display used: LCD Temperature measuring range: -40...537°C Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS AC DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC current measuring accuracy: ±(1.5% + 2 digit) Weight with battery: 550g Diode test: 1mA @6V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Temperature measurement accuracy: ±(1% + 10 digit) Frequency measuring accuracy: ±(0.1%+1 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Interface: Bluetooth Test voltage: 500V Dimensions (W x H x D): 100x203x50mm Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Resistance measuring accuracy: ±(0.9%+2 digit) Illumination: yes AC voltage measuring accuracy: ±(1% + 3 digit) Type of meter: digital multimeter IP rating: IP40 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature |
на замовлення 29 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1587 T | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Power supply: battery LR6 AA 1,5V x4 DC voltage measuring accuracy: ±(0.09% + 2 digit) Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Optional equipment: FLK-C25 soft cover DC current measuring accuracy: ±(0.2% + 2 digit) Kind of display used: LCD Temperature measuring range: -40...537°C Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC current measuring accuracy: ±(1.5% + 2 digit) Diode test: 1mA @6V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Insulation resistance measuring ranges: 10kΩ...100MΩ Temperature measurement accuracy: ±(1% + 10 digit) Frequency measuring accuracy: ±(0.1%+1 digit) Test voltage: 50V; 100V Dimensions (W x H x D): 100x203x50mm Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Resistance measuring accuracy: ±(0.9%+2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Type of meter: digital multimeter IP rating: IP40 Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Display parameters: (6000) AC current measuring range: 10µA...60mA; 400mA Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Temperature measurement resolution: 0.1°C Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Capacitance measuring accuracy: ±(1.2%+ 2 digit) Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function |
на замовлення 2 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1587/MDT FC | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual Related items: POM-5906A; POM-5907A; POM-6041B Type of measuring kit: multimeters |
на замовлення 3 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-15B+/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; resistance Kind of display used: LCD Display parameters: (4000) DC voltage measuring range: 4V; 40V; 400V; 1kV DC voltage measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring range: 4V; 40V; 400V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring range: 4A; 10A DC current measuring accuracy: ±(1.5% + 3 digit) AC current measuring range: 4A; 10A AC current measuring accuracy: ±(1.5% + 3 digit) Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF Capacitance measuring accuracy: ±(2%+ 5 digit) Resistance measuring accuracy: ±(0.5%+2 digit) Diode test: 2V Power supply: battery LR6 AA 1,5V x2 Conform to the norm: CAT III 600V; EN 61010 Dimensions (W x H x D): 183x91x49.5mm Measuring instrument features: HOLD function; pocket size Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Illumination: yes Standard equipment: test leads ( 2pcs.) |
на замовлення 94 шт: термін постачання 14-30 дні (днів) |
|
|||||||
| FLUKE-1623-2 | Fluke |
Basic GEO Earth Ground Tester |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
|||||||
|
FLUKE-1623-2 | FLUKE |
Category: Earth Resistance MeterDescription: Meter: grounding resistance; LCD; (1999); >50mA; 0.001÷19.99kΩ Kind of display used: LCD IP rating: IP56 Conform to the norm: CAT II 300V; EN 61010 Power supply: battery LR6 AA 1,5V x6 Measuring instrument features: low battery indicator; tests earth loop Standard equipment: holster; insulated crocodile clips; test leads Body dimensions: 133x187x250mm Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Illumination: yes Display height 1: 25mm Test current: >50mA Type of meter: grounding resistance Earthing resistance measuring range: 0.001...19.99kΩ Earthing resistance measuring accuracy: ±(2% + 2 digit) Measurement: AC earthing resistance by means of 2-pole method; earthing resistance; ground resistivity; resistance (3-wire); resistance (4-wire) Display parameters: (1999) Test voltage: 48V Kind of measurement: pushbutton activated; selective |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
|
FLUKE-1623-2 KIT | FLUKE |
Category: Earth Resistance MeterDescription: Measuring kit: a set of electrical installation meters Type of measuring kit: a set of electrical installation meters Power supply: battery LR6 AA 1,5V x6 Kit contents: 2 clamps (inducing, current); 2x ground/earth cable (25m); ground/earth cable (50m); ground earth stake (4pcs.); soft case; tester FLK-1623; test leads x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
| FLUKE-1732/B | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: USB A; WiFi (option) Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: crocodile clip x4; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
| FLUKE-1732/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: USB A; WiFi (option) Measuring instrument features: memory built-in Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
|
FLUKE-1734/B | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: USB A; WiFi (option) Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: crocodile clip x4; MP1 magnet probe; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
| FLUKE-1734/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth (option); USB A; WiFi (option) Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; MP1 magnet probe; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Connect; Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
|
FLUKE-1736/B | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: USB A; WiFi (option) Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: crocodile clip x4; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
| FLUKE-1736/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth; USB; WiFi Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; mains cable; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
| FLUKE-1736/EUS-GOLD | FLUKE |
Category: Power Quality Analyzers Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth; USB; WiFi Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; mains cable; MP1 magnet probe x4; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
| FLUKE-1736/FPC EU | FLUKE |
Category: Power Quality Analyzers Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth; USB; WiFi Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; Fluke Premium Care- 1 year; mains cable; MP1 magnet probe x4; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
|
FLUKE-1738/B | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth (option); USB A; WiFi (option) Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: crocodile clip x4; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 0s; 1min; 1s; 5min; 5s; 10min; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Connect IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
| FLUKE-1738/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth; USB; WiFi Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Weight with battery: 1.1kg Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Connect; Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | |||||||
|
FLUKE-1738/FPC EU | FLUKE |
Category: Power Quality Analyzers Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase Kind of display used: colour; LCD TFT 4,3" Interface: Bluetooth; USB; WiFi Measuring instrument features: memory built-in; transfer measurement data wireless Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; Fluke Premium Care- 1 year; MP1 magnet probe x4; test leads; USB cable Dimensions: 198x167x90mm Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Touchpad: yes Operating temperature: -10...50°C Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s Display resolution: 480x272 Connectors for the country: Europe Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power logger Software: Fluke Connect; Fluke Energy Analyze Plus IP rating: IP50 Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
|
FLUKE-1742/B/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 230x180x54mm Manufacturer series: FLK-174X IP rating: IP65 Measuring instrument features: memory built-in; transfer measurement data wireless Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Operating temperature: -25...50°C Dimensions: 230x180x54mm Weight with battery: 1kg Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; reactive power Interface: Bluetooth; Ethernet; USB; WiFi Standard equipment: case; crocodile clip x4; test leads; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Connect |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
|
FLUKE-1746/B/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 230x180x54mm Power supply: rechargeable battery Li-Ion 3,7V x1 IP rating: IP65 Interface: Bluetooth; Ethernet; USB; WiFi Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power quality logger Software: Fluke Connect Manufacturer series: FLK-174X Kind of network: three-phase Operating temperature: -25...50°C Dimensions: 230x180x54mm Weight with battery: 1kg Measuring instrument features: memory built-in; transfer measurement data wireless Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power Standard equipment: case; crocodile clip x4; test leads; USB cable Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
|
FLUKE-1748/15/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 230x180x54mm Interface: Bluetooth; Ethernet; USB; WiFi Standard equipment: case; crocodile clip x4; iFlex1500IP-24 - current clamp; test leads; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Connect IP rating: IP65 Measuring instrument features: memory built-in; transfer measurement data wireless Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Operating temperature: -25...50°C Dimensions: 230x180x54mm Weight with battery: 1kg Manufacturer series: FLK-174X Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency) |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
|
FLUKE-1748/30/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 230x180x54mm Interface: Bluetooth; Ethernet; USB; WiFi Standard equipment: case; crocodile clip x4; iFlex3000IP-24 - current clamp; test leads; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Connect IP rating: IP65 Measuring instrument features: memory built-in; transfer measurement data wireless Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Power supply: rechargeable battery Li-Ion 3,7V x1 Kind of network: three-phase Operating temperature: -25...50°C Dimensions: 230x180x54mm Weight with battery: 1kg Manufacturer series: FLK-174X Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency) |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
|
FLUKE-1748/B/EUS | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 230x180x54mm Power supply: rechargeable battery Li-Ion 3,7V x1 IP rating: IP65 Interface: Bluetooth; Ethernet; USB; WiFi Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power quality logger Software: Fluke Connect Manufacturer series: FLK-174X Kind of network: three-phase Operating temperature: -25...50°C Dimensions: 230x180x54mm Weight with battery: 1kg Measuring instrument features: memory built-in; transfer measurement data wireless Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency) Standard equipment: case; crocodile clip x4; test leads; USB cable Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 |
товару немає в наявності |
В кошику од. на суму грн. | ||||||
| FLUKE-175 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Display parameters: 3,75 digit (6000) AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Battery/ rechargeable battery: battery 6LR61 9V x1 Capacitance measuring accuracy: ±(1.2%+ 2 digit) Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Power supply: battery 6LR61 9V x1 Manufacturer series: Fluke 170 DC voltage measuring accuracy: ±(0.15% + 2 digit) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set DC current measuring accuracy: ±(1% + 3 digit) Kind of display used: LCD Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS AC DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC current measuring accuracy: ±(1.5% + 3 digit) Weight with battery: 420g Diode test: 1.1mA @2.4V Bargraph: 33 segm. 40x/s Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 89x190x45mm Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance |
на замовлення 52 шт: термін постачання 14-30 дні (днів) |
|
|||||||
|
FLUKE-175/F | FLUKE |
Description: FLUKE - FLUKE-175/F - Tragbares DMM, Produktreihe 170, 6000 Zählwerte, TRMS, automatisch, manuell, 3.75-stellig, 10A, 1kVtariffCode: 90303100 Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV Messwert Widerstand, max.: 50Mohm Messwert Gleichstrom, max.: 10A rohsCompliant: YES hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Schritte: 6000 Herstellergewährleistung: Lebenslang euEccn: NLR Anzahl der Stellen: 3.75 DMM-Messverfahren: Echteffektivwert DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Diode, Frequenz, Widerstand Produktpalette: 170 Series productTraceability: No Messwert Wechselstrom, max.: 10A Bereichswahl: Automatisch, manuell SVHC: No SVHC (15-Jun-2015) |
на замовлення 8 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
| FLUKE-177 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Kind of display used: LCD Display parameters: 3,75 digit (6000) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring accuracy: ±(1% + 3 digit) AC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring accuracy: ±(1.5% + 3 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1.2%+ 2 digit) Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Diode test: 1.1mA @2.4V Continuity test: acoustic indication; <25Ω Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 89x190x45mm Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Battery/ rechargeable battery: battery 6LR61 9V x1 Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Manufacturer series: Fluke 170 Bargraph: 33 segm. 40x/s Weight with battery: 420g |
на замовлення 63 шт: термін постачання 14-30 дні (днів) |
|
|||||||
|
FLUKE-177-2002-02 | FLUKE |
Category: Accessories - Others Description: Case Type of test accessories: case Related items: FLK-175; FLK-177; FLK-179 |
на замовлення 5 шт: термін постачання 14-30 дні (днів) |
|
||||||
|
FLUKE-1773/BASIC | FLUKE |
Description: FLUKE - FLUKE-1773/BASIC - Leistungsanalysator, Strom, Energie, Oberschwingungen, Leistung, Spannung, 1 Kanal, 50V bis 1kV tariffCode: 90308900 rohsCompliant: YES Anzahl der Kanäle: 1 Kanal hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: TBA Analysatorfunktionen: Strom, Energie, Oberschwingungen, Leistung, Spannung Spannungsbereich rms: 50V bis 1kV usEccn: 3A992.a Außenbreite: 7.5" Außentiefe: 11" euEccn: NLR Außenhöhe: 2.4" Produktpalette: 1770 Series Bandbreite: 30kHz productTraceability: No SVHC: No SVHC (15-Jun-2015) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. | ||||||
| FLUKE-1773/BASIC | FLUKE |
Category: Power Quality Analyzers Description: Meter: power quality logger; Network: three-phase; 280x190x62mm Power supply: rechargeable battery Li-Ion x1 IP rating: IP50 Interface: Bluetooth (option); Ethernet; USB; WiFi (option) Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: power quality logger Software: Fluke Energy Analyze Plus Manufacturer series: FLK-1770 Kind of network: three-phase Operating temperature: -10...50°C Dimensions: 280x190x62mm Weight with battery: 2.1kg Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M Battery/ rechargeable battery: rechargeable battery Li-Ion x1 |
товару немає в наявності |
В кошику од. на суму грн. |
| FLUKE TI-SBP3 |
![]() |
Виробник: FLUKE
Description: FLUKE - FLUKE TI-SBP3 - Akku, Fluke Ti125/Ti110/Ti100, Lithium-Ionen
tariffCode: 85076000
productTraceability: No
rohsCompliant: NA
Batterie-/Akkutechnologie: Lithium-Ionen
euEccn: NLR
hazardous: true
hazardCode: 3480
rohsPhthalatesCompliant: NA
Zur Verwendung mit: Wärmebildkameras Fluke Ti125, Ti110 für industrielle/gewerbliche Anwendungen & universell einsetzbare Wärmebildkameras Fluke Ti100
usEccn: EAR99
Produktpalette: -
SVHC: No SVHC (15-Jun-2015)
Description: FLUKE - FLUKE TI-SBP3 - Akku, Fluke Ti125/Ti110/Ti100, Lithium-Ionen
tariffCode: 85076000
productTraceability: No
rohsCompliant: NA
Batterie-/Akkutechnologie: Lithium-Ionen
euEccn: NLR
hazardous: true
hazardCode: 3480
rohsPhthalatesCompliant: NA
Zur Verwendung mit: Wärmebildkameras Fluke Ti125, Ti110 für industrielle/gewerbliche Anwendungen & universell einsetzbare Wärmebildkameras Fluke Ti100
usEccn: EAR99
Produktpalette: -
SVHC: No SVHC (15-Jun-2015)
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE TI-VISOR2 |
Виробник: Fluke
Glare Protection
Glare Protection
на замовлення 2 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 2+ | 7379.20 грн |
| FLUKE TL175 |
Виробник: FLUKE
Description: FLUKE - FLUKE TL175 - Messleitungssatz, Tastkopfspitze, 4mm-Bananenstecker, abgewinkelt, mit Kragen, 1 kV, 10 A
tariffCode: 90309000
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
Anschlusslänge - metrisch: 1.2m
Anzahl der Messleitungen: 2
Anschlusslänge - imperial: 3.94ft
usEccn: EAR99
Nennstrom: 10A
Teststecker B: 4mm-Bananenstecker, abgewinkelt, mit Kragen
euEccn: NLR
Isolatorfarbe: Schwarz, Rot
Produktpalette: -
productTraceability: No
Nennspannung: 1kV
Teststecker A: Tastkopfspitze
SVHC: No SVHC (12-Jan-2017)
Description: FLUKE - FLUKE TL175 - Messleitungssatz, Tastkopfspitze, 4mm-Bananenstecker, abgewinkelt, mit Kragen, 1 kV, 10 A
tariffCode: 90309000
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
Anschlusslänge - metrisch: 1.2m
Anzahl der Messleitungen: 2
Anschlusslänge - imperial: 3.94ft
usEccn: EAR99
Nennstrom: 10A
Teststecker B: 4mm-Bananenstecker, abgewinkelt, mit Kragen
euEccn: NLR
Isolatorfarbe: Schwarz, Rot
Produktpalette: -
productTraceability: No
Nennspannung: 1kV
Teststecker A: Tastkopfspitze
SVHC: No SVHC (12-Jan-2017)
на замовлення 213 шт:
термін постачання 21-31 дні (днів)
| FLUKE TL225-1 |
![]() |
Виробник: FLUKE
Description: FLUKE - FLUKE TL225-1 - Kit, Messleitungen TL224, Streuspannungsadapter SV225, SureGrip-Messfühlersatz TP220, Tasche
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
Lieferumfang des Kits: Messleitungssatz (TL224), Streuspannungsadapter (SV225), Satz SureGrip-Messfühler (TP220), Zubehörtasche (C75)
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
SVHC: No SVHC (15-Jun-2015)
Description: FLUKE - FLUKE TL225-1 - Kit, Messleitungen TL224, Streuspannungsadapter SV225, SureGrip-Messfühlersatz TP220, Tasche
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
Lieferumfang des Kits: Messleitungssatz (TL224), Streuspannungsadapter (SV225), Satz SureGrip-Messfühler (TP220), Zubehörtasche (C75)
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
SVHC: No SVHC (15-Jun-2015)
на замовлення 5 шт:
термін постачання 21-31 дні (днів)
| FLUKE TL71-1 |
![]() |
Виробник: FLUKE
Description: FLUKE - FLUKE TL71-1 - Messleitungssatz, Tastkopfspitze, 4mm-Bananenstecker, abgewinkelt, mit Kragen, 1 kV, 10 A
tariffCode: 90309000
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
Anschlusslänge - metrisch: 1.2m
Anzahl der Messleitungen: 2
Anschlusslänge - imperial: 4ft
usEccn: EAR99
Nennstrom: 10A
Teststecker B: 4mm-Bananenstecker, abgewinkelt, mit Kragen
euEccn: NLR
Isolatorfarbe: Schwarz, Rot
Produktpalette: -
productTraceability: No
Nennspannung: 1kV
Teststecker A: Tastkopfspitze
SVHC: No SVHC (23-Jan-2024)
Description: FLUKE - FLUKE TL71-1 - Messleitungssatz, Tastkopfspitze, 4mm-Bananenstecker, abgewinkelt, mit Kragen, 1 kV, 10 A
tariffCode: 90309000
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
Anschlusslänge - metrisch: 1.2m
Anzahl der Messleitungen: 2
Anschlusslänge - imperial: 4ft
usEccn: EAR99
Nennstrom: 10A
Teststecker B: 4mm-Bananenstecker, abgewinkelt, mit Kragen
euEccn: NLR
Isolatorfarbe: Schwarz, Rot
Produktpalette: -
productTraceability: No
Nennspannung: 1kV
Teststecker A: Tastkopfspitze
SVHC: No SVHC (23-Jan-2024)
на замовлення 49 шт:
термін постачання 21-31 дні (днів)
| FLUKE TL71-1 |
Виробник: Fluke
Test Lead Set Premium Dmm
Test Lead Set Premium Dmm
на замовлення 3 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 3+ | 5600.38 грн |
| FLUKE TL75-1 |
Виробник: Fluke
Hard Point TM Test Lead Set
Hard Point TM Test Lead Set
на замовлення 2 шт:
термін постачання 21-31 дні (днів)
| FLUKE TLK281-1 |
Виробник: FLUKE
Description: FLUKE - FLUKE TLK281-1 - Messleitungskit, Kfz, Einstechklemmen, Messleitungen, Tastköpfe, Krokodilklemmen, Tasche
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
SVHC: To Be Advised
Description: FLUKE - FLUKE TLK281-1 - Messleitungskit, Kfz, Einstechklemmen, Messleitungen, Tastköpfe, Krokodilklemmen, Tasche
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
SVHC: To Be Advised
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| FLUKE TP220-1 |
Виробник: FLUKE
Description: FLUKE - FLUKE TP220-1 - Tastkopfsatz, rote & schwarze industrielle Tastköpfe, 12mm-Edelstahlspitze, flexibler Fingerschutz
tariffCode: 90309000
productTraceability: No
rohsCompliant: Y-EX
Lieferumfang des Kits: 1 Paar rote & schwarze industrielle Messspitzen, 12mm-Edelstahlspitze, flexibler Fingerschutz
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
Description: FLUKE - FLUKE TP220-1 - Tastkopfsatz, rote & schwarze industrielle Tastköpfe, 12mm-Edelstahlspitze, flexibler Fingerschutz
tariffCode: 90309000
productTraceability: No
rohsCompliant: Y-EX
Lieferumfang des Kits: 1 Paar rote & schwarze industrielle Messspitzen, 12mm-Edelstahlspitze, flexibler Fingerschutz
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
на замовлення 12 шт:
термін постачання 21-31 дні (днів)
| FLUKE TPAK TOOLPAK |
Виробник: Fluke
FLUKE TPAK TOOLPAK
FLUKE TPAK TOOLPAK
на замовлення 3 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 2+ | 7447.38 грн |
| 3+ | 7210.14 грн |
| FLUKE UA120 |
Виробник: FLUKE
Description: FLUKE - FLUKE UA120 - Messzubehör, USB-Steckverbinder-Adapter
tariffCode: 85176200
Art des Zubehörs: USB-Steckverbinder-Adapter
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
SVHC: No SVHC (15-Jun-2015)
Description: FLUKE - FLUKE UA120 - Messzubehör, USB-Steckverbinder-Adapter
tariffCode: 85176200
Art des Zubehörs: USB-Steckverbinder-Adapter
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: -
SVHC: No SVHC (15-Jun-2015)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| FLUKE-110 |
Виробник: Fluke
FLUKE-110
FLUKE-110
на замовлення 2 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 22625.02 грн |
| FLUKE-113 EUR |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V
Conform to the norm: CAT III 600V; EN 61010
Type of meter: digital multimeter
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC voltage measuring range: 1mV...6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 404g
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Measurement: capacitance; DC voltage; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Kind of display used: LCD
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V
Conform to the norm: CAT III 600V; EN 61010
Type of meter: digital multimeter
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC voltage measuring range: 1mV...6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 404g
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Measurement: capacitance; DC voltage; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Kind of display used: LCD
на замовлення 24 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 13548.78 грн |
| FLUKE-114 EUR |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Manufacturer series: Fluke 110
Battery/ rechargeable battery: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Pollution degree: 2
Kind of display used: LCD
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Weight with battery: 550g
Bargraph: 33 segm. 32x/s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Type of meter: digital multimeter
Measurement: AC voltage; DC voltage; resistance
Display parameters: 3,75 digit (6000)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Manufacturer series: Fluke 110
Battery/ rechargeable battery: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Pollution degree: 2
Kind of display used: LCD
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Weight with battery: 550g
Bargraph: 33 segm. 32x/s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Type of meter: digital multimeter
Measurement: AC voltage; DC voltage; resistance
Display parameters: 3,75 digit (6000)
на замовлення 20 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 18448.33 грн |
| FLUKE-115 EUR |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
Manufacturer series: Fluke 110
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Related items: POM-5543B; POM-6275; POM-6343
DC current measuring accuracy: ±(1% + 3 digit)
Pollution degree: 2
Kind of display used: LCD
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 550g
Diode test: 1.2mA @2.7V
Bargraph: 33 segm. 32x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring accuracy: ±(0.1%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Type of meter: digital multimeter
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
Manufacturer series: Fluke 110
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Related items: POM-5543B; POM-6275; POM-6343
DC current measuring accuracy: ±(1% + 3 digit)
Pollution degree: 2
Kind of display used: LCD
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 550g
Diode test: 1.2mA @2.7V
Bargraph: 33 segm. 32x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring accuracy: ±(0.1%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Type of meter: digital multimeter
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
на замовлення 104 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 18608.74 грн |
| FLUKE-116 EUR |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0.1% + 2 digit)
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Pollution degree: 2
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 550g
Diode test: 1.2mA @2.7V
Bargraph: 33 segm. 32x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring accuracy: ±(0.1%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Measuring instruments application: air conditioning; heating industry; ventilation
AC current measuring range: 0.1...600µA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Manufacturer series: Fluke 110
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
DC current measuring accuracy: ±(1% + 2 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0.1% + 2 digit)
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Pollution degree: 2
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 550g
Diode test: 1.2mA @2.7V
Bargraph: 33 segm. 32x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring accuracy: ±(0.1%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Measuring instruments application: air conditioning; heating industry; ventilation
AC current measuring range: 0.1...600µA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Manufacturer series: Fluke 110
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
DC current measuring accuracy: ±(1% + 2 digit)
на замовлення 20 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 26153.16 грн |
| FLUKE-116/323 KIT |
![]() |
Виробник: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Type of measuring kit: multimeters
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Type of measuring kit: multimeters
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
на замовлення 5 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 37960.02 грн |
| FLUKE-116/323-KIT |
Виробник: Fluke
FLUKE-116/323-KIT
FLUKE-116/323-KIT
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 61209.20 грн |
| FLUKE-117 EUR |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
Manufacturer series: Fluke 110
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Optional equipment: FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Related items: POM-5673B; POM-5900A/POM; POM-7519A
DC current measuring accuracy: ±(1% + 3 digit)
Pollution degree: 2
Kind of display used: LCD
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 550g
Diode test: 1.2mA @2.7V
Bargraph: 33 segm. 32x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring accuracy: ±(0.1%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
Manufacturer series: Fluke 110
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Optional equipment: FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Related items: POM-5673B; POM-5900A/POM; POM-7519A
DC current measuring accuracy: ±(1% + 3 digit)
Pollution degree: 2
Kind of display used: LCD
Continuity test: acoustic indication; <20Ω
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 550g
Diode test: 1.2mA @2.7V
Bargraph: 33 segm. 32x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring accuracy: ±(0.1%+2 digit)
Dimensions (W x H x D): 84x167x46mm
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
на замовлення 71 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 26347.81 грн |
| FLUKE-123B/EU |
![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Dimensions: 259x132x55mm
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Manufacturer series: FLUKE 120B
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Type of oscilloscope: scopemeter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Continuity test: acoustic indication
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Sampling: 40Msps
Display resolution: 640x480
Diode test: 0.5mA @2.8V
Connectors for the country: Europe
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Band: 20MHz
Time base: 20n...60s/div
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.6%+5 digit)
Additional functions: multimeter
Number of channels: 2
IP rating: IP51
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Dimensions: 259x132x55mm
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Manufacturer series: FLUKE 120B
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Type of oscilloscope: scopemeter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Continuity test: acoustic indication
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Sampling: 40Msps
Display resolution: 640x480
Diode test: 0.5mA @2.8V
Connectors for the country: Europe
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Band: 20MHz
Time base: 20n...60s/div
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.6%+5 digit)
Additional functions: multimeter
Number of channels: 2
IP rating: IP51
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
на замовлення 2 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 182720.66 грн |
| FLUKE-123B/EU/S |
![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Type of oscilloscope: scopemeter
Band: 20MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 20n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Type of oscilloscope: scopemeter
Band: 20MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 20n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-124B/EU |
![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Dimensions: 259x132x55mm
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Manufacturer series: FLUKE 120B
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Type of oscilloscope: scopemeter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Continuity test: acoustic indication
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Sampling: 40Msps
Display resolution: 640x480
Diode test: 0.5mA @2.8V
Connectors for the country: Europe
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Band: 40MHz
Time base: 10n...60s/div
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.6%+5 digit)
Additional functions: multimeter
Number of channels: 2
IP rating: IP51
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Dimensions: 259x132x55mm
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Manufacturer series: FLUKE 120B
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Type of oscilloscope: scopemeter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Continuity test: acoustic indication
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Sampling: 40Msps
Display resolution: 640x480
Diode test: 0.5mA @2.8V
Connectors for the country: Europe
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Band: 40MHz
Time base: 10n...60s/div
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.6%+5 digit)
Additional functions: multimeter
Number of channels: 2
IP rating: IP51
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
на замовлення 2 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 215682.00 грн |
| FLUKE-124B/EU/S |
![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-125B/EU |
![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-125B/EU/S |
![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
на замовлення 1 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 313600.00 грн |
| FLUKE-1503 |
![]() |
Виробник: Fluke
Insulation Resistance Tester
Insulation Resistance Tester
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 93545.81 грн |
| FLUKE-1503 |
![]() |
Виробник: Fluke
Insulation Resistance Tester
Insulation Resistance Tester
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 87255.34 грн |
| FLUKE-1503 |
![]() |
Виробник: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
IP rating: IP40
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Automatic discharging capacitance: max. 1µF
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance discharge time: <0.5s
Bandwidth for AC voltage measurements: 50...400Hz
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(2% + 3 digit)
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: POM-5674C; POM-5907A; POM-6041B
Kind of display used: LCD
Continuity test: acoustic indication
DC voltage measuring range: 100mV...600V
Open circuit test voltage: 4...8V
Weight with battery: 550g
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V DC; 1kV DC
Conform to the norm: CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(1.5%+3 digit)
Illumination: yes
AC voltage measuring accuracy: ±(2% + 3 digit)
Type of meter: insulation resistance
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
IP rating: IP40
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Automatic discharging capacitance: max. 1µF
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance discharge time: <0.5s
Bandwidth for AC voltage measurements: 50...400Hz
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(2% + 3 digit)
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: POM-5674C; POM-5907A; POM-6041B
Kind of display used: LCD
Continuity test: acoustic indication
DC voltage measuring range: 100mV...600V
Open circuit test voltage: 4...8V
Weight with battery: 550g
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V DC; 1kV DC
Conform to the norm: CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(1.5%+3 digit)
Illumination: yes
AC voltage measuring accuracy: ±(2% + 3 digit)
Type of meter: insulation resistance
на замовлення 11 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 39982.20 грн |
| FLUKE-1507 |
![]() |
Виробник: Fluke
Insulation Resistance Tester
Insulation Resistance Tester
на замовлення 3 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 82078.59 грн |
| 2+ | 79813.80 грн |
| 3+ | 77844.05 грн |
| FLUKE-1507 |
![]() |
Виробник: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance discharge time: <0.5s
Bandwidth for AC voltage measurements: 50...400Hz
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(2% + 3 digit)
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: POM-5674C; POM-5907A; POM-6041B
Kind of display used: LCD
Continuity test: acoustic indication
DC voltage measuring range: 100mV...600V
Open circuit test voltage: 4...8V
Weight with battery: 550g
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Conform to the norm: CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(1.5%+3 digit)
Illumination: yes
AC voltage measuring accuracy: ±(2% + 3 digit)
Type of meter: insulation resistance
IP rating: IP40
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Automatic discharging capacitance: max. 1µF
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance discharge time: <0.5s
Bandwidth for AC voltage measurements: 50...400Hz
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(2% + 3 digit)
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: POM-5674C; POM-5907A; POM-6041B
Kind of display used: LCD
Continuity test: acoustic indication
DC voltage measuring range: 100mV...600V
Open circuit test voltage: 4...8V
Weight with battery: 550g
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Conform to the norm: CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(1.5%+3 digit)
Illumination: yes
AC voltage measuring accuracy: ±(2% + 3 digit)
Type of meter: insulation resistance
IP rating: IP40
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Automatic discharging capacitance: max. 1µF
на замовлення 31 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 50392.28 грн |
| FLUKE-1577 |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
на замовлення 2 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 70839.35 грн |
| FLUKE-1587 FC |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Display parameters: (6000)
AC current measuring range: 10µA...60mA; 400mA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Temperature measurement resolution: 0.1°C
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Optional equipment: FLK-C25 soft cover
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
DC current measuring accuracy: ±(0.2% + 2 digit)
Kind of display used: LCD
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1.5% + 2 digit)
Weight with battery: 550g
Diode test: 1mA @6V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Temperature measurement accuracy: ±(1% + 10 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Interface: Bluetooth
Test voltage: 500V
Dimensions (W x H x D): 100x203x50mm
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+2 digit)
Illumination: yes
AC voltage measuring accuracy: ±(1% + 3 digit)
Type of meter: digital multimeter
IP rating: IP40
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Display parameters: (6000)
AC current measuring range: 10µA...60mA; 400mA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Temperature measurement resolution: 0.1°C
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Optional equipment: FLK-C25 soft cover
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
DC current measuring accuracy: ±(0.2% + 2 digit)
Kind of display used: LCD
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1.5% + 2 digit)
Weight with battery: 550g
Diode test: 1mA @6V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Temperature measurement accuracy: ±(1% + 10 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Interface: Bluetooth
Test voltage: 500V
Dimensions (W x H x D): 100x203x50mm
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+2 digit)
Illumination: yes
AC voltage measuring accuracy: ±(1% + 3 digit)
Type of meter: digital multimeter
IP rating: IP40
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
на замовлення 29 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 82617.38 грн |
| FLUKE-1587 T |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Optional equipment: FLK-C25 soft cover
DC current measuring accuracy: ±(0.2% + 2 digit)
Kind of display used: LCD
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1.5% + 2 digit)
Diode test: 1mA @6V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Insulation resistance measuring ranges: 10kΩ...100MΩ
Temperature measurement accuracy: ±(1% + 10 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Test voltage: 50V; 100V
Dimensions (W x H x D): 100x203x50mm
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Resistance measuring accuracy: ±(0.9%+2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Type of meter: digital multimeter
IP rating: IP40
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Display parameters: (6000)
AC current measuring range: 10µA...60mA; 400mA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Temperature measurement resolution: 0.1°C
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Optional equipment: FLK-C25 soft cover
DC current measuring accuracy: ±(0.2% + 2 digit)
Kind of display used: LCD
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1.5% + 2 digit)
Diode test: 1mA @6V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Insulation resistance measuring ranges: 10kΩ...100MΩ
Temperature measurement accuracy: ±(1% + 10 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Test voltage: 50V; 100V
Dimensions (W x H x D): 100x203x50mm
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Resistance measuring accuracy: ±(0.9%+2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Type of meter: digital multimeter
IP rating: IP40
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Display parameters: (6000)
AC current measuring range: 10µA...60mA; 400mA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Temperature measurement resolution: 0.1°C
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
на замовлення 2 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 76704.04 грн |
| FLUKE-1587/MDT FC |
![]() |
Виробник: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Related items: POM-5906A; POM-5907A; POM-6041B
Type of measuring kit: multimeters
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Related items: POM-5906A; POM-5907A; POM-6041B
Type of measuring kit: multimeters
на замовлення 3 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 111097.30 грн |
| FLUKE-15B+/EUR |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; resistance
Kind of display used: LCD
Display parameters: (4000)
DC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring range: 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 4A; 10A
DC current measuring accuracy: ±(1.5% + 3 digit)
AC current measuring range: 4A; 10A
AC current measuring accuracy: ±(1.5% + 3 digit)
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
Capacitance measuring accuracy: ±(2%+ 5 digit)
Resistance measuring accuracy: ±(0.5%+2 digit)
Diode test: 2V
Power supply: battery LR6 AA 1,5V x2
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 183x91x49.5mm
Measuring instrument features: HOLD function; pocket size
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Standard equipment: test leads ( 2pcs.)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; resistance
Kind of display used: LCD
Display parameters: (4000)
DC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring range: 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 4A; 10A
DC current measuring accuracy: ±(1.5% + 3 digit)
AC current measuring range: 4A; 10A
AC current measuring accuracy: ±(1.5% + 3 digit)
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
Capacitance measuring accuracy: ±(2%+ 5 digit)
Resistance measuring accuracy: ±(0.5%+2 digit)
Diode test: 2V
Power supply: battery LR6 AA 1,5V x2
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 183x91x49.5mm
Measuring instrument features: HOLD function; pocket size
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Standard equipment: test leads ( 2pcs.)
на замовлення 94 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 9279.14 грн |
| FLUKE-1623-2 |
![]() |
Виробник: Fluke
Basic GEO Earth Ground Tester
Basic GEO Earth Ground Tester
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 309355.74 грн |
| FLUKE-1623-2 |
![]() |
Виробник: FLUKE
Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; (1999); >50mA; 0.001÷19.99kΩ
Kind of display used: LCD
IP rating: IP56
Conform to the norm: CAT II 300V; EN 61010
Power supply: battery LR6 AA 1,5V x6
Measuring instrument features: low battery indicator; tests earth loop
Standard equipment: holster; insulated crocodile clips; test leads
Body dimensions: 133x187x250mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Illumination: yes
Display height 1: 25mm
Test current: >50mA
Type of meter: grounding resistance
Earthing resistance measuring range: 0.001...19.99kΩ
Earthing resistance measuring accuracy: ±(2% + 2 digit)
Measurement: AC earthing resistance by means of 2-pole method; earthing resistance; ground resistivity; resistance (3-wire); resistance (4-wire)
Display parameters: (1999)
Test voltage: 48V
Kind of measurement: pushbutton activated; selective
Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; (1999); >50mA; 0.001÷19.99kΩ
Kind of display used: LCD
IP rating: IP56
Conform to the norm: CAT II 300V; EN 61010
Power supply: battery LR6 AA 1,5V x6
Measuring instrument features: low battery indicator; tests earth loop
Standard equipment: holster; insulated crocodile clips; test leads
Body dimensions: 133x187x250mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Illumination: yes
Display height 1: 25mm
Test current: >50mA
Type of meter: grounding resistance
Earthing resistance measuring range: 0.001...19.99kΩ
Earthing resistance measuring accuracy: ±(2% + 2 digit)
Measurement: AC earthing resistance by means of 2-pole method; earthing resistance; ground resistivity; resistance (3-wire); resistance (4-wire)
Display parameters: (1999)
Test voltage: 48V
Kind of measurement: pushbutton activated; selective
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1623-2 KIT |
![]() |
Виробник: FLUKE
Category: Earth Resistance Meter
Description: Measuring kit: a set of electrical installation meters
Type of measuring kit: a set of electrical installation meters
Power supply: battery LR6 AA 1,5V x6
Kit contents: 2 clamps (inducing, current); 2x ground/earth cable (25m); ground/earth cable (50m); ground earth stake (4pcs.); soft case; tester FLK-1623; test leads x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Category: Earth Resistance Meter
Description: Measuring kit: a set of electrical installation meters
Type of measuring kit: a set of electrical installation meters
Power supply: battery LR6 AA 1,5V x6
Kit contents: 2 clamps (inducing, current); 2x ground/earth cable (25m); ground/earth cable (50m); ground earth stake (4pcs.); soft case; tester FLK-1623; test leads x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1732/B |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1732/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in
Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in
Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1734/B |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; MP1 magnet probe; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; MP1 magnet probe; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1734/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth (option); USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; MP1 magnet probe; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect; Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth (option); USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; MP1 magnet probe; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect; Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1736/B |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1736/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; mains cable; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; mains cable; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1736/EUS-GOLD |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; mains cable; MP1 magnet probe x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; mains cable; MP1 magnet probe x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1736/FPC EU |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; Fluke Premium Care- 1 year; mains cable; MP1 magnet probe x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; Fluke Premium Care- 1 year; mains cable; MP1 magnet probe x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1738/B |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth (option); USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 0s; 1min; 1s; 5min; 5s; 10min; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth (option); USB A; WiFi (option)
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 0s; 1min; 1s; 5min; 5s; 10min; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1738/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect; Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Weight with battery: 1.1kg
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect; Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1738/FPC EU |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; Fluke Premium Care- 1 year; MP1 magnet probe x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect; Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
Category: Power Quality Analyzers
Description: Meter: power logger; colour,LCD TFT 4,3"; Network: three-phase
Kind of display used: colour; LCD TFT 4,3"
Interface: Bluetooth; USB; WiFi
Measuring instrument features: memory built-in; transfer measurement data wireless
Standard equipment: adapter WiFi; bluetooth adapter; crocodile clip x4; FLK-i17XX-FLEX1500 - current clamp; Fluke Premium Care- 1 year; MP1 magnet probe x4; test leads; USB cable
Dimensions: 198x167x90mm
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: from tested wiring system; mains power supply; rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Touchpad: yes
Operating temperature: -10...50°C
Sampling rate: 1min; 1s; 5min; 5s; 10min; 10s; 15min; 30min; 30s
Display resolution: 480x272
Connectors for the country: Europe
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power logger
Software: Fluke Connect; Fluke Energy Analyze Plus
IP rating: IP50
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; reactive power
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1742/B/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Manufacturer series: FLK-174X
IP rating: IP65
Measuring instrument features: memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; reactive power
Interface: Bluetooth; Ethernet; USB; WiFi
Standard equipment: case; crocodile clip x4; test leads; USB cable
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Manufacturer series: FLK-174X
IP rating: IP65
Measuring instrument features: memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; reactive power
Interface: Bluetooth; Ethernet; USB; WiFi
Standard equipment: case; crocodile clip x4; test leads; USB cable
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1746/B/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Power supply: rechargeable battery Li-Ion 3,7V x1
IP rating: IP65
Interface: Bluetooth; Ethernet; USB; WiFi
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power quality logger
Software: Fluke Connect
Manufacturer series: FLK-174X
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Measuring instrument features: memory built-in; transfer measurement data wireless
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power
Standard equipment: case; crocodile clip x4; test leads; USB cable
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Power supply: rechargeable battery Li-Ion 3,7V x1
IP rating: IP65
Interface: Bluetooth; Ethernet; USB; WiFi
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power quality logger
Software: Fluke Connect
Manufacturer series: FLK-174X
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Measuring instrument features: memory built-in; transfer measurement data wireless
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power
Standard equipment: case; crocodile clip x4; test leads; USB cable
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1748/15/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Interface: Bluetooth; Ethernet; USB; WiFi
Standard equipment: case; crocodile clip x4; iFlex1500IP-24 - current clamp; test leads; USB cable
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
IP rating: IP65
Measuring instrument features: memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Manufacturer series: FLK-174X
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency)
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Interface: Bluetooth; Ethernet; USB; WiFi
Standard equipment: case; crocodile clip x4; iFlex1500IP-24 - current clamp; test leads; USB cable
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
IP rating: IP65
Measuring instrument features: memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Manufacturer series: FLK-174X
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency)
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1748/30/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Interface: Bluetooth; Ethernet; USB; WiFi
Standard equipment: case; crocodile clip x4; iFlex3000IP-24 - current clamp; test leads; USB cable
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
IP rating: IP65
Measuring instrument features: memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Manufacturer series: FLK-174X
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency)
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Interface: Bluetooth; Ethernet; USB; WiFi
Standard equipment: case; crocodile clip x4; iFlex3000IP-24 - current clamp; test leads; USB cable
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
IP rating: IP65
Measuring instrument features: memory built-in; transfer measurement data wireless
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Power supply: rechargeable battery Li-Ion 3,7V x1
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Manufacturer series: FLK-174X
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency)
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-1748/B/EUS |
![]() |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Power supply: rechargeable battery Li-Ion 3,7V x1
IP rating: IP65
Interface: Bluetooth; Ethernet; USB; WiFi
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power quality logger
Software: Fluke Connect
Manufacturer series: FLK-174X
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Measuring instrument features: memory built-in; transfer measurement data wireless
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency)
Standard equipment: case; crocodile clip x4; test leads; USB cable
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 230x180x54mm
Power supply: rechargeable battery Li-Ion 3,7V x1
IP rating: IP65
Interface: Bluetooth; Ethernet; USB; WiFi
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power quality logger
Software: Fluke Connect
Manufacturer series: FLK-174X
Kind of network: three-phase
Operating temperature: -25...50°C
Dimensions: 230x180x54mm
Weight with battery: 1kg
Measuring instrument features: memory built-in; transfer measurement data wireless
Measurement: AC current; active power; AC voltage; apparent power; energy; frequency; harmonics; inrush current; reactive power; transients (low frequency)
Standard equipment: case; crocodile clip x4; test leads; USB cable
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
товару немає в наявності
В кошику
од. на суму грн.
| FLUKE-175 EGFID |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Power supply: battery 6LR61 9V x1
Manufacturer series: Fluke 170
DC voltage measuring accuracy: ±(0.15% + 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
DC current measuring accuracy: ±(1% + 3 digit)
Kind of display used: LCD
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 420g
Diode test: 1.1mA @2.4V
Bargraph: 33 segm. 40x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Battery/ rechargeable battery: battery 6LR61 9V x1
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Power supply: battery 6LR61 9V x1
Manufacturer series: Fluke 170
DC voltage measuring accuracy: ±(0.15% + 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
DC current measuring accuracy: ±(1% + 3 digit)
Kind of display used: LCD
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC current measuring accuracy: ±(1.5% + 3 digit)
Weight with battery: 420g
Diode test: 1.1mA @2.4V
Bargraph: 33 segm. 40x/s
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
на замовлення 52 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 24986.17 грн |
| FLUKE-175/F |
![]() |
Виробник: FLUKE
Description: FLUKE - FLUKE-175/F - Tragbares DMM, Produktreihe 170, 6000 Zählwerte, TRMS, automatisch, manuell, 3.75-stellig, 10A, 1kV
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 50Mohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Schritte: 6000
Herstellergewährleistung: Lebenslang
euEccn: NLR
Anzahl der Stellen: 3.75
DMM-Messverfahren: Echteffektivwert
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Diode, Frequenz, Widerstand
Produktpalette: 170 Series
productTraceability: No
Messwert Wechselstrom, max.: 10A
Bereichswahl: Automatisch, manuell
SVHC: No SVHC (15-Jun-2015)
Description: FLUKE - FLUKE-175/F - Tragbares DMM, Produktreihe 170, 6000 Zählwerte, TRMS, automatisch, manuell, 3.75-stellig, 10A, 1kV
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 50Mohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Schritte: 6000
Herstellergewährleistung: Lebenslang
euEccn: NLR
Anzahl der Stellen: 3.75
DMM-Messverfahren: Echteffektivwert
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Diode, Frequenz, Widerstand
Produktpalette: 170 Series
productTraceability: No
Messwert Wechselstrom, max.: 10A
Bereichswahl: Automatisch, manuell
SVHC: No SVHC (15-Jun-2015)
на замовлення 8 шт:
термін постачання 21-31 дні (днів)
| FLUKE-177 EGFID |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1.5% + 3 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Diode test: 1.1mA @2.4V
Continuity test: acoustic indication; <25Ω
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 89x190x45mm
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Battery/ rechargeable battery: battery 6LR61 9V x1
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1.5% + 3 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Diode test: 1.1mA @2.4V
Continuity test: acoustic indication; <25Ω
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 89x190x45mm
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Battery/ rechargeable battery: battery 6LR61 9V x1
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
на замовлення 63 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 33301.98 грн |
| FLUKE-177-2002-02 |
Виробник: FLUKE
Category: Accessories - Others
Description: Case
Type of test accessories: case
Related items: FLK-175; FLK-177; FLK-179
Category: Accessories - Others
Description: Case
Type of test accessories: case
Related items: FLK-175; FLK-177; FLK-179
на замовлення 5 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна без ПДВ |
|---|---|
| 1+ | 2134.82 грн |
| FLUKE-1773/BASIC |
Виробник: FLUKE
Description: FLUKE - FLUKE-1773/BASIC - Leistungsanalysator, Strom, Energie, Oberschwingungen, Leistung, Spannung, 1 Kanal, 50V bis 1kV
tariffCode: 90308900
rohsCompliant: YES
Anzahl der Kanäle: 1 Kanal
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: TBA
Analysatorfunktionen: Strom, Energie, Oberschwingungen, Leistung, Spannung
Spannungsbereich rms: 50V bis 1kV
usEccn: 3A992.a
Außenbreite: 7.5"
Außentiefe: 11"
euEccn: NLR
Außenhöhe: 2.4"
Produktpalette: 1770 Series
Bandbreite: 30kHz
productTraceability: No
SVHC: No SVHC (15-Jun-2015)
Description: FLUKE - FLUKE-1773/BASIC - Leistungsanalysator, Strom, Energie, Oberschwingungen, Leistung, Spannung, 1 Kanal, 50V bis 1kV
tariffCode: 90308900
rohsCompliant: YES
Anzahl der Kanäle: 1 Kanal
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: TBA
Analysatorfunktionen: Strom, Energie, Oberschwingungen, Leistung, Spannung
Spannungsbereich rms: 50V bis 1kV
usEccn: 3A992.a
Außenbreite: 7.5"
Außentiefe: 11"
euEccn: NLR
Außenhöhe: 2.4"
Produktpalette: 1770 Series
Bandbreite: 30kHz
productTraceability: No
SVHC: No SVHC (15-Jun-2015)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)
| FLUKE-1773/BASIC |
Виробник: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Interface: Bluetooth (option); Ethernet; USB; WiFi (option)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power quality logger
Software: Fluke Energy Analyze Plus
Manufacturer series: FLK-1770
Kind of network: three-phase
Operating temperature: -10...50°C
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Power supply: rechargeable battery Li-Ion x1
IP rating: IP50
Interface: Bluetooth (option); Ethernet; USB; WiFi (option)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: power quality logger
Software: Fluke Energy Analyze Plus
Manufacturer series: FLK-1770
Kind of network: three-phase
Operating temperature: -10...50°C
Dimensions: 280x190x62mm
Weight with battery: 2.1kg
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; manufacturer's calibration certificate; test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
товару немає в наявності
В кошику
од. на суму грн.