Продукція > FLUKE > Всі товари виробника FLUKE (5245) > Сторінка 81 з 88

Обрати Сторінку:    << Попередня Сторінка ]  1 8 16 24 32 40 48 56 64 72 76 77 78 79 80 81 82 83 84 85 86 88  Наступна Сторінка >> ]
Фото Назва Виробник Інформація Доступність
Ціна
FLUKE-117 EUR
+5
FLUKE-117 EUR FLUKE Fluke 117 Datasheet EN.pdf 114_____umeng0100.pdf Manual 114-115-117 (EN).pdf 114_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
на замовлення 43 шт:
термін постачання 21-30 дні (днів)
1+25107.28 грн
В кошику  од. на суму  грн.
FLUKE-175 EGFID
+4
FLUKE-175 EGFID FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.15% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
на замовлення 80 шт:
термін постачання 21-30 дні (днів)
1+26245.09 грн
В кошику  од. на суму  грн.
FLUKE-177 EGFID
+5
FLUKE-177 EGFID FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
на замовлення 76 шт:
термін постачання 21-30 дні (днів)
1+30905.37 грн
В кошику  од. на суму  грн.
FLUKE-179 EGFID
+4
FLUKE-179 EGFID FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
на замовлення 85 шт:
термін постачання 21-30 дні (днів)
1+37086.44 грн
В кошику  од. на суму  грн.
FLUKE-1577
+4
FLUKE-1577 FLUKE pVersion=0046&contRep=ZT&docId=E1C0437DAD5969F1A6F5005056AB5A8F&compId=10923-eng.pdf?ci_sign=405a3fb1328d5640fa1ce617ba5a9ad3d7cbe1e2 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A545F569126B&compId=15x7____umeng0200.pdf?ci_sign=664cb0ef1bb450f817ae8bd311361866019f4c31 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A545F56A326B&compId=15x7____umger0200.pdf?ci_sign=59d05502c365e05aeefea97069b0f453abeda551 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Kind of display used: LCD
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(1.2%+2 digit)
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Weight with battery: 550g
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Dimensions (W x H x D): 100x203x50mm
DC current measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
DC current measuring range: 10µA...60mA; 400mA
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
1+66026.19 грн
В кошику  од. на суму  грн.
2824477
+1
2824477 FLUKE Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
на замовлення 7 шт:
термін постачання 21-30 дні (днів)
1+5205.57 грн
В кошику  од. на суму  грн.
FLK-3000FC/EDA2
+5
FLK-3000FC/EDA2 FLUKE Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+42459.46 грн
В кошику  од. на суму  грн.
FLUKE-179/EDA2/EUR
+9
FLUKE-179/EDA2/EUR FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB514A95E060C4&compId=Fluke%20175%20177%20179%20Datasheet%20EN.pdf?ci_sign=fe41a9ef2fc771de581f0328e0c4195a0703df43 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A8E91A6AD26B&compId=175_____umeng0100.pdf?ci_sign=8194b9efcda3893604b3162237d8cf33454a2af1 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6FFF8F1A60C4&compId=Fluke%20175%20177%20179%20Manual%20EN.pdf?ci_sign=afdd439682deeeededcd306a397e76c770974bd9 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A8E91A6BF26B&compId=175_____umger0100.pdf?ci_sign=2d8f7b9e76217791cd0810f988cc18138466efda pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6FFF8F1A00C4&compId=Fluke%20175%20177%20179%20Manual%20DE.pdf?ci_sign=780385361d5ef80979f800a9b70444087d9cdcc0 Category: Portable digital multimeters
Description: Digital multimeter
Type of meter: digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+41661.70 грн
В кошику  од. на суму  грн.
FLUKE-179/MAG2 KIT
+8
FLUKE-179/MAG2 KIT FLUKE 175_____umeng0100.pdf 175_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Related items: POM-5904A/POM; POM-6343; POM-7519A
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
1+34922.46 грн
В кошику  од. на суму  грн.
FLUKE-T110 FLUKE-T110 FLUKE pVersion=0046&contRep=ZT&docId=005056AB752F1EE2BBEEC2B07D3CF672&compId=FLK-T90-DTE.pdf?ci_sign=dbeb26611662defe11dc0eb630fe1afdb068f1c3 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC8452C0C4&compId=Fluke%20T110%20Datasheet%20(EN).pdf?ci_sign=a66a1c9d7205f44084d92db87734affa3ae3aa50 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC845260C4&compId=Fluke%20T110%20Datasheet%20(DE).pdf?ci_sign=49ab722f3f8b4426b816a67d4130016467f07e29 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBAC0C4&compId=Fluke%20T110%20Manual%20(EN).pdf?ci_sign=f9aeca48fd9cfc456aa48c8229e39a673e3f0f3a pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBA60C4&compId=Fluke%20T110%20Manual%20(DE).pdf?ci_sign=b8fe2a248dd20c44fb10987831688515f468ade4 Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
на замовлення 42 шт:
термін постачання 21-30 дні (днів)
1+8455.82 грн
В кошику  од. на суму  грн.
FLUKE T110/VDE FLUKE T110/VDE FLUKE pVersion=0046&contRep=ZT&docId=005056AB752F1EE2BBEEC2B07D3CF672&compId=FLK-T90-DTE.pdf?ci_sign=dbeb26611662defe11dc0eb630fe1afdb068f1c3 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC8452C0C4&compId=Fluke%20T110%20Datasheet%20(EN).pdf?ci_sign=a66a1c9d7205f44084d92db87734affa3ae3aa50 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC845260C4&compId=Fluke%20T110%20Datasheet%20(DE).pdf?ci_sign=49ab722f3f8b4426b816a67d4130016467f07e29 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38133D26B&compId=T110vde_iseng0000.pdf?ci_sign=08b573cadbb76cd86d67ac9c4ffbbccb926c083e pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBAC0C4&compId=Fluke%20T110%20Manual%20(EN).pdf?ci_sign=f9aeca48fd9cfc456aa48c8229e39a673e3f0f3a pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBA60C4&compId=Fluke%20T110%20Manual%20(DE).pdf?ci_sign=b8fe2a248dd20c44fb10987831688515f468ade4 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38134326B&compId=T110vde_isger0000.pdf?ci_sign=36fcd4b0bf31658852664943b04459582eccfd6f Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
1+8114.91 грн
В кошику  од. на суму  грн.
FLUKE-T90
+2
FLUKE-T90 FLUKE FLK-T90-DTE.pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
IP rating: IP54
Kind of display used: LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 245x64x28mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 180g
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 50 шт:
термін постачання 21-30 дні (днів)
1+5780.91 грн
В кошику  од. на суму  грн.
FLUKE-T130 FLUKE-T130 FLUKE FLK-T90-DTE.pdf Fluke T130 Datasheet (EN).pdf Fluke T130 Datasheet (DE).pdf Fluke T130 Manual (EN).pdf Fluke T130 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 27 шт:
термін постачання 21-30 дні (днів)
1+12236.77 грн
В кошику  од. на суму  грн.
FLUKE T130/VDE FLUKE T130/VDE FLUKE pVersion=0046&contRep=ZT&docId=005056AB752F1EE2BBEEC2B07D3CF672&compId=FLK-T90-DTE.pdf?ci_sign=dbeb26611662defe11dc0eb630fe1afdb068f1c3 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38133D26B&compId=T110vde_iseng0000.pdf?ci_sign=08b573cadbb76cd86d67ac9c4ffbbccb926c083e pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38134326B&compId=T110vde_isger0000.pdf?ci_sign=36fcd4b0bf31658852664943b04459582eccfd6f Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Type of tester: electrical
Additional functions: illumination lamp
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
на замовлення 13 шт:
термін постачання 21-30 дні (днів)
1+12399.93 грн
В кошику  од. на суму  грн.
FLUKE-T150 FLUKE-T150 FLUKE FLK-T90-DTE.pdf Fluke T150 Datasheet (EN).pdf Fluke T150 Datasheet (DE).pdf Fluke T150 Manual (EN).pdf Fluke T150 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 51 шт:
термін постачання 21-30 дні (днів)
1+14110.50 грн
В кошику  од. на суму  грн.
FLUKE T150/VDE FLUKE T150/VDE FLUKE FLK-T90-DTE.pdf Fluke T150 Datasheet (EN).pdf Fluke T150 Datasheet (DE).pdf T110vde_iseng0000.pdf Fluke T150 Manual (EN).pdf T110vde_isger0000.pdf Fluke T150 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 34 шт:
термін постачання 21-30 дні (днів)
1+14117.37 грн
В кошику  од. на суму  грн.
FLUKE-787B
+5
FLUKE-787B FLUKE FLK-787B.pdf FLK-787B-INS.pdf Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+114377.33 грн
В кошику  од. на суму  грн.
FLUKE-789/E
+2
FLUKE-789/E FLUKE 10591-eng.pdf Fluke 789 Datasheet (EN).pdf 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf Fluke 789 Datasheet (DE).pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf Fluke 789 Manual (EN).pdf Fluke 789 Manual (DE).pdf Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(1.2% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
1+135116.30 грн
В кошику  од. на суму  грн.
FLUKE-88-5/A KIT
+13
FLUKE-88-5/A KIT FLUKE pVersion=0046&contRep=ZT&docId=E1C04C497262E8F1A6F5005056AB5A8F&compId=FLK-88V-A.PDF?ci_sign=deac5a68a71906aed903ea76cba790e957166f0a pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3BDB2B360D26B&compId=88v_____umeng0100.pdf?ci_sign=fa3769da2efe8c3b485834be513e4fa71b470966 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3BDB2B361926B&compId=88v_____umger0100.pdf?ci_sign=bcf025080ea97028c6b64dbeac500a83195e1a36 Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Kind of display used: LCD
Temperature measuring range: -200...1090°C
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 0...10000µF
AC current measuring range: 0...10A
DC current measuring range: 0...10A
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
Frequency measuring range: 0...200kHz
Resistance measuring range: 0...50MΩ
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: yes
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+73489.34 грн
В кошику  од. на суму  грн.
FLUKE-279FC/IFLEX
+2
FLUKE-279FC/IFLEX FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB52000CACE0C4&compId=Fluke%20279%20FC%20Datasheet%20(EN).pdf?ci_sign=88a37b1b46af8d1be54746442f04159046cddcfb pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB52000CAC80C4&compId=Fluke%20279%20FC%20Datasheet%20(DE).pdf?ci_sign=76a87f396fedd875e6b82acc56be6e7165a6ab35 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB71F0339EC0C4&compId=Fluke%20279%20FC%20Manual%20(EN).pdf?ci_sign=bb8f84e360521c93027d34593a336bbd3be39efe pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB71F0339E60C4&compId=Fluke%20279%20FC%20Manual%20(DE).pdf?ci_sign=dbe2c9776c0738cd475dbbf5658eb91738405579 Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Type of meter: digital multimeter with infrared camera
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Interface: Bluetooth
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Resistance measuring range: 600Ω...50MΩ
Diode test: 2V
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Connectors for the country: Europe; Great Britain
Focusing: focus free
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+101366.85 грн
В кошику  од. на суму  грн.
FLK-3000FC
+5
FLK-3000FC FLUKE pVersion=0046&contRep=ZT&docId=005056AB752F1ED3BADCEC489A36E1EC&compId=FLK-3000FC-DTE.pdf?ci_sign=274b2d1f57869caab82a3312eeeded5d0c04094d pVersion=0046&contRep=ZT&docId=005056AB752F1EE59CCF4429D084611C&compId=6001874B-EN-FC-Reasons-Why-Flyer-w.pdf?ci_sign=da606f061daab71629ac91be27a63bb69521bd00 pVersion=0046&contRep=ZT&docId=005056AB752F1EE59CCF4429D084011C&compId=6001874B-de-FC-Reasons-Why-Flyer-w.pdf?ci_sign=852d87b78b6ca3e900a603555c0cb57305888414 pVersion=0046&contRep=ZT&docId=005056AB752F1EE7A2B33DD17A230749&compId=FLK-3000FC-INS.pdf?ci_sign=5154cb47d651719728a9224ca3d975ac08fcc97e Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
IP rating: IP54
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: compatible Android; Fluke Connect
Type of meter: digital multimeter
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Dimensions (W x H x D): 93x207x48mm
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 340g
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
товару немає в наявності
В кошику  од. на суму  грн.
FLUKE-1587 T
+5
FLUKE-1587 T FLUKE 15x7____umeng0200.pdf 15x7____umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring accuracy: ±(0.9%+2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
1+73092.61 грн
В кошику  од. на суму  грн.
FLUKE-123B/EU
+3
FLUKE-123B/EU FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+168408.92 грн
В кошику  од. на суму  грн.
FLUKE-123B/EU/S
+15
FLUKE-123B/EU/S FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5000FED9A0C4&compId=Fluke%20120B%20Series%20Datasheet%20EN.pdf?ci_sign=a5ebaad24d8d1282c737c335f280bef908081cd8 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5000FED940C4&compId=Fluke%20120B%20Series%20Datasheet%20DE.pdf?ci_sign=4c48c813b22b8330e969d6b1e2543ea3691b30d4 pVersion=0046&contRep=ZT&docId=005056AB752F1EE7A2B33D360FA86749&compId=FLK-123B-INS.pdf?ci_sign=d809318c3150f95924f06ca75781d606784590f9 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6B9A207060C4&compId=Fluke%20120B%20Series%20Manual%20EN.pdf?ci_sign=779552c31c3f407e876b2618621d42b81ee9b42d pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6B9A207000C4&compId=Fluke%20120B%20Series%20Manual%20DE.pdf?ci_sign=6c9ed74c3a5ca94480af1467caeb00836baf16e3 Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Kind of display used: colour; LCD TFT 5,7"
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Resistance measuring accuracy: ±(0.6%+5 digit)
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Related items: POM-72941; POM-72942
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Band: 20MHz
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Software: Fluke View
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Dimensions: 259x132x55mm
Number of channels: 2
Display resolution: 640x480
товару немає в наявності
В кошику  од. на суму  грн.
FLUKE-124B/EU
+16
FLUKE-124B/EU FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+205527.12 грн
В кошику  од. на суму  грн.
FLUKE-124B/EU/S
+15
FLUKE-124B/EU/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+251227.40 грн
В кошику  од. на суму  грн.
FLUKE-125B/EU
+5
FLUKE-125B/EU FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+241375.30 грн
В кошику  од. на суму  грн.
FLUKE-125B/EU/S
+16
FLUKE-125B/EU/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+291952.24 грн
В кошику  од. на суму  грн.
FLUKE-1587 FC
+3
FLUKE-1587 FC FLUKE Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf Fluke 1587 FC Manual (EN).pdf 15x7____umeng0200.pdf 15x7____umger0200.pdf Fluke 1587 FC Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 500V
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Optional equipment: FLK-C25 soft cover
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
на замовлення 14 шт:
термін постачання 21-30 дні (днів)
1+79242.77 грн
В кошику  од. на суму  грн.
FLK-115/TLK-225-1
+13
FLK-115/TLK-225-1 FLUKE Fluke 115 Datasheet (english).pdf Manual 114-115-117 (EN).pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
на замовлення 118 шт:
термін постачання 21-30 дні (днів)
1+24009.84 грн
В кошику  од. на суму  грн.
FLUKE-27II/EUR
+5
FLUKE-27II/EUR FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A248B43E9B60C7&compId=FLK-27-2.pdf?ci_sign=d0aed22e26219f5838da0547365e065d433266e4 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E60526B&compId=2x_2____umeng0100.pdf?ci_sign=c6d1f2ae200a92ddcdf33d2f539cdea85cd7bbe8 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E61726B&compId=2x_2____umger0100.pdf?ci_sign=65a463467fa490f910365cab7636f5dc01fb1244 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+61024.15 грн
В кошику  од. на суму  грн.
FLUKE-28II/EUR
+7
FLUKE-28II/EUR FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F60C4&compId=Fluke%2028-II%20Datasheet%20EN.pdf?ci_sign=badd75d31ad4aff62277d71d5923d927de08a858 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F00C4&compId=Fluke%2028-II%20Datasheet%20DE.pdf?ci_sign=562ef99f3a78d2cc628933285d66eb65030abdd9 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7271A03B00C4&compId=Fluke%2028-II%20Manual%20EN.pdf?ci_sign=0241b174a2cf9fe0368b6013f8efa557d854ced9 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E60526B&compId=2x_2____umeng0100.pdf?ci_sign=c6d1f2ae200a92ddcdf33d2f539cdea85cd7bbe8 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E61726B&compId=2x_2____umger0100.pdf?ci_sign=65a463467fa490f910365cab7636f5dc01fb1244 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7271A03AA0C4&compId=Fluke%2028-II%20Manual%20DE.pdf?ci_sign=a22ce0460ef07b095ef6180642c5c58bed7040e8 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 5 шт:
термін постачання 21-30 дні (днів)
1+60756.22 грн
В кошику  од. на суму  грн.
FLUKE-28IIEX
+5
FLUKE-28IIEX FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F60C4&compId=Fluke%2028-II%20Datasheet%20EN.pdf?ci_sign=badd75d31ad4aff62277d71d5923d927de08a858 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F00C4&compId=Fluke%2028-II%20Datasheet%20DE.pdf?ci_sign=562ef99f3a78d2cc628933285d66eb65030abdd9 pVersion=0046&contRep=ZT&docId=005056AB281E1FD0AA83B4CC651B00E2&compId=28-2EX%20EN%20manual.pdf?ci_sign=73708985684cb6e870d2f337a3f39d8ad2f5afb1 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E60526B&compId=2x_2____umeng0100.pdf?ci_sign=c6d1f2ae200a92ddcdf33d2f539cdea85cd7bbe8 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E61726B&compId=2x_2____umger0100.pdf?ci_sign=65a463467fa490f910365cab7636f5dc01fb1244 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+145584.11 грн
В кошику  од. на суму  грн.
FLUKE-381
+10
FLUKE-381 FLUKE Fluke 381 Datasheet EN.pdf Fluke 381 Datasheet DE.pdf Fluke 381 Manual EN.pdf Fluke 381 Manual DE.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Body dimensions: 277x88x43mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+63126.29 грн
В кошику  од. на суму  грн.
FLUKE-83-5/EUR
+5
FLUKE-83-5/EUR FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB57AC98D3C0C4&compId=Fluke%2083V%2087V%20Datasheet%20EN.pdf?ci_sign=6f6761d31c14f198f38c843a8350d3786b45c1ae pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB57AC98D360C4&compId=Fluke%2083V%2087V%20Datasheet%20DE.pdf?ci_sign=27f0c66fffdec0dd1555819d18bca5abc7b390ee pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7B6EBEDFA0C4&compId=fluke%2083%20V%20Manual%20(EN).pdf?ci_sign=63b9521b719932ad3b2195f1f2c865b4ea0e5d2c pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7B6EBEDF40C4&compId=fluke%2083%20V%20Manual%20(DE).pdf?ci_sign=e3545330dfc4d2263435839b27cb3b76fc70ef11 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
IP rating: IP30
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+43514.82 грн
В кошику  од. на суму  грн.
FLUKE-87-5/EUR
+6
FLUKE-87-5/EUR FLUKE Fluke 87 V Datasheet (EN).pdf Fluke 87 V Datasheet (DE).pdf Fluke 87 V Manual (EN).pdf Fluke 87 V Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Type of meter: digital multimeter
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Bargraph: 33 segm. 40x/s
Weight with battery: 600g
Display parameters: (6000/20000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
на замовлення 20 шт:
термін постачання 21-30 дні (днів)
1+45187.61 грн
В кошику  од. на суму  грн.
FLUKE-87V-MAX FLUKE-87V-MAX FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A24B3DB542E0C7&compId=FLK-87VMAX.pdf?ci_sign=f2b600c409bf92e18a0cad187a57c7381571a747 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
1+57995.44 грн
В кошику  од. на суму  грн.
FLUKE-87V-MAX/E2 KIT
+3
FLUKE-87V-MAX/E2 KIT FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A24B3DB542E0C7&compId=FLK-87VMAX.pdf?ci_sign=f2b600c409bf92e18a0cad187a57c7381571a747 Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+68495.02 грн
В кошику  од. на суму  грн.
FLK-87VMAX-PVLEAD1
+3
FLK-87VMAX-PVLEAD1 FLUKE Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+61396.83 грн
В кошику  од. на суму  грн.
FLUKE-374 FC
+9
FLUKE-374 FC FLUKE Fluke 374 FC Datasheet (EN).pdf Fluke 374 FC Datasheet (DE).pdf Fluke 374 FC Manual (EN).pdf Fluke 374 FC Manual (DE).pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC voltage measuring range: 100mV...600V
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+40248.25 грн
В кошику  од. на суму  грн.
FLUKE-375 FC
+9
FLUKE-375 FC FLUKE Fluke 375 FC Datasheet (EN).pdf Fluke 375 FC Datasheet (DE).pdf Fluke 375 FC Manual (EN).pdf Fluke 375 FC Manual (DE).pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+47195.30 грн
В кошику  од. на суму  грн.
FLUKE-376 FC
+12
FLUKE-376 FC FLUKE Fluke 376 FC Datasheet (EN).pdf Fluke 376 FC Datasheet (DE).pdf Fluke 376 FC Manual (EN).pdf Fluke 376 FC Manual (DE).pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 1...1000µF
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
Resistance measuring range: 0.1...60kΩ
DC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
на замовлення 42 шт:
термін постачання 21-30 дні (днів)
1+51217.55 грн
В кошику  од. на суму  грн.
FLUKE-902 FC
+7
FLUKE-902 FC FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB580BE9C340C4&compId=Fluke%20902FC%20Datasheet%20EN.pdf?ci_sign=0cd42217de9076fba01030e1ba6d5f6c7b96cf8f pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB580BE9C2E0C4&compId=Fluke%20902FC%20Datasheet%20DE.pdf?ci_sign=3cf54f937eaaf39bb82fe5d2754452a9b52c3c44 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7BD9C80B40C4&compId=Fluke%20902FC%20Manual%20EN.pdf?ci_sign=c0a6f19ea58f6239cfb5166da7101dac3a359f40 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7BD9C80AE0C4&compId=Fluke%20902FC%20Manual%20DE.pdf?ci_sign=c3e629bc74c7fb197eea0ce758afb7d5519f7be4 Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Kind of meter: digital; pincers type
Type of meter: multifunction
Software: Fluke Connect
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Kind of display used: LCD
Illumination: yes
Resistance to: shockproof
True effective value measurement: True RMS AC
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 0.1...200µA
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1.5%+5 digit)
DC voltage measuring range: 100mV...600V
Dimensions: 240x80x40mm
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Weight with battery: 310g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <30Ω
Measuring instruments application: air conditioning; heating industry; ventilation
на замовлення 7 шт:
термін постачання 21-30 дні (днів)
1+31557.99 грн
В кошику  од. на суму  грн.
FLUKE-323
+7
FLUKE-323 FLUKE Fluke 32x Datasheet EN.pdf Fluke 32x Datasheet DE.pdf 32x_____umeng0000.pdf Fluke 32x Manual EN.pdf 32x_____umger0000.pdf Fluke 32x Manual DE.pdf Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ
DC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 265g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
на замовлення 57 шт:
термін постачання 21-30 дні (днів)
1+12604.31 грн
В кошику  од. на суму  грн.
FLUKE-325
+9
FLUKE-325 FLUKE Fluke 32x Datasheet EN.pdf Fluke 32x Datasheet DE.pdf 32x_____umeng0000.pdf Fluke 32x Manual EN.pdf 32x_____umger0000.pdf Fluke 32x Manual DE.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 10mA...40A; 400A
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
DC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 283g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
на замовлення 61 шт:
термін постачання 21-30 дні (днів)
1+22047.66 грн
В кошику  од. на суму  грн.
FLUKE-378 FC/E
+6
FLUKE-378 FC/E FLUKE FLK-377FC_378FC_EN.pdf Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Type of meter: multifunction
Kind of meter: digital; pincers type
Max. diameter of measured cable: 34mm
Kind of display used: LCD
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring range: 600V; 1kV
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 600V; 1kV
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 0.1...100µF; 1mF
Capacitance measuring accuracy: ±(1%+ 4 digit)
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Continuity test: acoustic indication; <30Ω
Test: diodes
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Pollution degree: 2
Dimensions: 274x86x47mm
Weight with battery: 463g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Interface: Bluetooth
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Software: Fluke Connect
на замовлення 19 шт:
термін постачання 21-30 дні (днів)
1+59339.34 грн
В кошику  од. на суму  грн.
TL71-1 TL71-1 FLUKE Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Type of test accessories: test leads
Rated voltage: 1kV
Colour: red and black
Test lead configuration: banana plug 4mm; probe tip
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Wire insulation material: silicone
Kit contents: test leads x2
Cable length: 1.5m
Current rating: 10A
на замовлення 64 шт:
термін постачання 21-30 дні (днів)
1+3477.82 грн
В кошику  од. на суму  грн.
TP40 TP40 FLUKE TestToolCatalog_2006-2007.pdf Category: Probes - Test Plugs
Description: Set of measuring probes; 60VDC; Kit: test probes x5
Type of test accessories: set of measuring probes
Kit contents: test probes x5
Rated voltage: 60V DC
Related items: FLK-TL222; FLK-TL224
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
1+5025.23 грн
В кошику  од. на суму  грн.
FLUKE-289/FVF/EUR
+10
FLUKE-289/FVF/EUR FLUKE pVersion=0046&contRep=ZT&docId=005056AB752F1ED39CF0959E175549E4&compId=FLK-289FVF-DTE.PDF?ci_sign=fec92aec968422eb3c6a9cbc254c6e89ecb2e3e8 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5284B9D1A0C4&compId=Fluke%20289%20Datasheet%20EN.pdf?ci_sign=aeb563671b4b8adabf3c3a558ab2df963eb3f624 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5284B9D140C4&compId=Fluke%20289%20Datasheet%20DE.pdf?ci_sign=8aa946e18ea4e57cab4fd9914bf83e1bc5332993 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3ABD82A22D26B&compId=287_289_umeng0200.pdf?ci_sign=c7a088a38ba19679213c139da66c3a6a3228e2be pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB73517BB9E0C4&compId=Fluke%20287%20%26%20289%20Manual%20EN.pdf?ci_sign=649be04c6557a15b17a70c1226226026ab0b65e4 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3ABD82A23F26B&compId=287_289_umger0200.pdf?ci_sign=3c13dd504be36215deb9e69dffc9c5a600259708 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB73517BB980C4&compId=Fluke%20287%20%26%20289%20Manual%20DE.pdf?ci_sign=0753434097b27284a283cbd7a83fee9c0279c50a Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Type of meter: digital multimeter
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Software: Fluke View
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
1+86271.40 грн
В кошику  од. на суму  грн.
FLK-289/FVF/IR3000
+14
FLK-289/FVF/IR3000 FLUKE Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Type of meter: digital multimeter
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Software: Fluke View Forms
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+99949.96 грн
В кошику  од. на суму  грн.
I2000 FLEX
+3
I2000 FLEX FLUKE i2000flxiseng0100.pdf i2000flxisger0100.pdf Category: Meters and AC Clamp Probes
Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
True effective value measurement: True RMS AC
AC current measuring range: 1...20A; 200A; 2kA
Max. diameter of measured cable: 178mm
Cable length: 0.5m
AC current measuring accuracy: ±1%
Bandwidth for AC current measurements: 10Hz...20kHz
Weight with battery: 420g
Max. operating voltage: 600V
Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A)
Display parameters: (3000)
Measurement: AC current
Type of test accessories: AC current clamp adapter
Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Standard equipment: BNC to banana plug adapter
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+36711.18 грн
В кошику  од. на суму  грн.
BP120MH BP120MH FLUKE Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; 4.8V; 3000mAh
Type of test accessories: rechargeable battery
Related items: FLK-43B; FLK-123
Capacity: 3Ah
Rated voltage: 4.8V
товару немає в наявності
В кошику  од. на суму  грн.
FLK-TIS55+ 9HZ
+4
FLK-TIS55+ 9HZ FLUKE TIS55+ TIS 75+.pdf Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 256x192
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 28° horizontal x 20° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+238049.45 грн
В кошику  од. на суму  грн.
FLK-TIS60+ 9HZ FLK-TIS60+ 9HZ FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A24CCDA3AB80C7&compId=FLK-TIS60%2B9HZ.pdf?ci_sign=01687eb4792b16585b5871236347996f8899be7e Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 320x240; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 320x240
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 34.1° horizontal x 25.6° vertical
Focusing: FocusFree
IP rating: IP54
Dimensions: 26.7x10.1x14.5mm
Power supply: rechargeable battery Li-Ion 7,4V x2
Measuring instrument features: adjustable display illumination; adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; case; hard case; microSD memory card; power supply; USB cable
Three-dimensional resolution: 1.86mrad
Thermal sensitivity (NETD): <0.045 @ 30°C
Resistance to: fall from 2m height
Measurement: temperature
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V x2
Display resolution: 320x240
Related items: FLK-TI-SBP3
Measuring unit: °C; °F
Interface: Bluetooth; LAN; USB; WiFi
товару немає в наявності
В кошику  од. на суму  грн.
FLK-TIS75+ 9HZ
+4
FLK-TIS75+ 9HZ FLUKE TIS55+ TIS 75+.pdf Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 384x288; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 384x288
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 42° horizontal x 30° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; carrying strap; case; hard case; microSD 4GB memory card; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Related items: FLK-TI-SBP3
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; IS3; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+396740.22 грн
В кошику  од. на суму  грн.
C25 C25 FLUKE Category: Bags & Soft Cases
Description: Cover; 218x128x64mm
Related items: FLK-27YEL; FLK-51-2-50HZ; FLK-52-2-50HZ; FLK-53-2-50HZ; FLK-54-2-50HZ; FLK-77-4; FLK-83V; FLK-87V; FLK-88V; FLK-114; FLK-115; FLK-116; FLK-117; FLK-175EGFID; FLK-177EGFID; FLK-179EGFID; FLK-712; FLK-714; FLK-715; FLK-717; FLK-724; FLK-725; FLK-726; FLK-787; FLK-789; FLK-922; FLK-971; FLK-1503; FLK-1507; FLK-1577; FLK-1587; FLK-9040; FLK-9062
Type of test accessories: cover
Dimensions: 218x128x64mm
товару немає в наявності
В кошику  од. на суму  грн.
FLUKE-87-5/E2K/EUR
+6
FLUKE-87-5/E2K/EUR FLUKE Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-87V; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; FLK-TL224 silicone test leads set; magnetic hanging strap FLK-TOOLPAK; test probes; test probes FLK-AC220 SureGrip
Type of meter: digital multimeter
Related items: POM-4408; POM-5519A; POM-5673B
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
1+53925.10 грн
В кошику  од. на суму  грн.
FLUKE-1587/MDT FC
+12
FLUKE-1587/MDT FC FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB4FDA7B8D60C4&compId=Fluke%201587%20FC%20Datasheet%20(EN).pdf?ci_sign=450e43c0b0eb3f3f0ac52de2c2032089160da3b3 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB4FDA7B8D00C4&compId=Fluke%201587%20FC%20Datasheet%20(DE).pdf?ci_sign=e88ac3f6dd1e3ceb088f550b6f47ca6e604099a0 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6C67640A60C4&compId=Fluke%201587%20FC%20Manual%20(EN).pdf?ci_sign=d5d9ce1986511b4cadc4ef4cf756cbb6e343ded6 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6C67640A00C4&compId=Fluke%201587%20FC%20Manual%20(DE).pdf?ci_sign=157c50f8ff726c7b66f7f7fcb06ed7ec421ee5c7 Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+105866.55 грн
В кошику  од. на суму  грн.
FLUKE-705
+2
FLUKE-705 FLUKE pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB560C292E80C4&compId=Fluke%20705%20Datasheet%20(EN).pdf?ci_sign=7a8af29bf2c4a4b812b13e8d471a08bbe67e98aa pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB79C9BCB520C4&compId=Fluke%20705%20Manual%20(EN).pdf?ci_sign=27cf7ccdb9392edb615f6941a6e4d324b4e68068 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB79C9BCB4C0C4&compId=Fluke%20705%20Manual%20(DE).pdf?ci_sign=7c72c101d03cab088857b92a1eba64f49a18adbf Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Measurement: DC current; DC voltage
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of display used: LCD
Kind of calibrator: loop
Type of meter: calibrator
Power supply: battery 6F22 9V x1
Current source accuracy: ±(0,025% + 2 digits)
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Dimensions: 201x98x52mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
товару немає в наявності
В кошику  од. на суму  грн.
FLK2AC/200-1000VCL
+2
FLK2AC/200-1000VCL FLUKE Fluke 2AC 200-1000V5 Datasheet (EN).pdf Fluke 2AC 200-1000V5 Datasheet (DE).pdf Fluke 2AC 200-1000V5 Manual (EN).pdf Fluke 2AC 200-1000V5 Manual (DE).pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC
Type of tester: non-contact voltage detector
Measuring instrument features: AutoTest function; battery level indication; optical (LED) indication of detected voltage
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Conform to the norm: CAT IV 1000V; EN 61010
Detected voltage range: 200...1000V AC
на замовлення 62 шт:
термін постачання 21-30 дні (днів)
1+3029.57 грн
В кошику  од. на суму  грн.
FLUKE-117 EUR Fluke 117 Datasheet EN.pdf 114_____umeng0100.pdf Manual 114-115-117 (EN).pdf 114_____umger0100.pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
на замовлення 43 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+25107.28 грн
В кошику  од. на суму  грн.
FLUKE-175 EGFID Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.15% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
на замовлення 80 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+26245.09 грн
В кошику  од. на суму  грн.
FLUKE-177 EGFID Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
на замовлення 76 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+30905.37 грн
В кошику  од. на суму  грн.
FLUKE-179 EGFID Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
на замовлення 85 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+37086.44 грн
В кошику  од. на суму  грн.
FLUKE-1577 pVersion=0046&contRep=ZT&docId=E1C0437DAD5969F1A6F5005056AB5A8F&compId=10923-eng.pdf?ci_sign=405a3fb1328d5640fa1ce617ba5a9ad3d7cbe1e2 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A545F569126B&compId=15x7____umeng0200.pdf?ci_sign=664cb0ef1bb450f817ae8bd311361866019f4c31 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A545F56A326B&compId=15x7____umger0200.pdf?ci_sign=59d05502c365e05aeefea97069b0f453abeda551
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Kind of display used: LCD
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(1.2%+2 digit)
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Weight with battery: 550g
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Dimensions (W x H x D): 100x203x50mm
DC current measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
DC current measuring range: 10µA...60mA; 400mA
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+66026.19 грн
В кошику  од. на суму  грн.
2824477
Виробник: FLUKE
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
на замовлення 7 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+5205.57 грн
В кошику  од. на суму  грн.
FLK-3000FC/EDA2
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+42459.46 грн
В кошику  од. на суму  грн.
FLUKE-179/EDA2/EUR pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB514A95E060C4&compId=Fluke%20175%20177%20179%20Datasheet%20EN.pdf?ci_sign=fe41a9ef2fc771de581f0328e0c4195a0703df43 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A8E91A6AD26B&compId=175_____umeng0100.pdf?ci_sign=8194b9efcda3893604b3162237d8cf33454a2af1 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6FFF8F1A60C4&compId=Fluke%20175%20177%20179%20Manual%20EN.pdf?ci_sign=afdd439682deeeededcd306a397e76c770974bd9 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3A8E91A6BF26B&compId=175_____umger0100.pdf?ci_sign=2d8f7b9e76217791cd0810f988cc18138466efda pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6FFF8F1A00C4&compId=Fluke%20175%20177%20179%20Manual%20DE.pdf?ci_sign=780385361d5ef80979f800a9b70444087d9cdcc0
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Type of meter: digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+41661.70 грн
В кошику  од. на суму  грн.
FLUKE-179/MAG2 KIT 175_____umeng0100.pdf 175_____umger0100.pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Related items: POM-5904A/POM; POM-6343; POM-7519A
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+34922.46 грн
В кошику  од. на суму  грн.
FLUKE-T110 pVersion=0046&contRep=ZT&docId=005056AB752F1EE2BBEEC2B07D3CF672&compId=FLK-T90-DTE.pdf?ci_sign=dbeb26611662defe11dc0eb630fe1afdb068f1c3 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC8452C0C4&compId=Fluke%20T110%20Datasheet%20(EN).pdf?ci_sign=a66a1c9d7205f44084d92db87734affa3ae3aa50 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC845260C4&compId=Fluke%20T110%20Datasheet%20(DE).pdf?ci_sign=49ab722f3f8b4426b816a67d4130016467f07e29 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBAC0C4&compId=Fluke%20T110%20Manual%20(EN).pdf?ci_sign=f9aeca48fd9cfc456aa48c8229e39a673e3f0f3a pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBA60C4&compId=Fluke%20T110%20Manual%20(DE).pdf?ci_sign=b8fe2a248dd20c44fb10987831688515f468ade4
FLUKE-T110
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
на замовлення 42 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+8455.82 грн
В кошику  од. на суму  грн.
FLUKE T110/VDE pVersion=0046&contRep=ZT&docId=005056AB752F1EE2BBEEC2B07D3CF672&compId=FLK-T90-DTE.pdf?ci_sign=dbeb26611662defe11dc0eb630fe1afdb068f1c3 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC8452C0C4&compId=Fluke%20T110%20Datasheet%20(EN).pdf?ci_sign=a66a1c9d7205f44084d92db87734affa3ae3aa50 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB58EC845260C4&compId=Fluke%20T110%20Datasheet%20(DE).pdf?ci_sign=49ab722f3f8b4426b816a67d4130016467f07e29 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38133D26B&compId=T110vde_iseng0000.pdf?ci_sign=08b573cadbb76cd86d67ac9c4ffbbccb926c083e pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBAC0C4&compId=Fluke%20T110%20Manual%20(EN).pdf?ci_sign=f9aeca48fd9cfc456aa48c8229e39a673e3f0f3a pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7D556BBA60C4&compId=Fluke%20T110%20Manual%20(DE).pdf?ci_sign=b8fe2a248dd20c44fb10987831688515f468ade4 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38134326B&compId=T110vde_isger0000.pdf?ci_sign=36fcd4b0bf31658852664943b04459582eccfd6f
FLUKE T110/VDE
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+8114.91 грн
В кошику  од. на суму  грн.
FLUKE-T90 FLK-T90-DTE.pdf
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
IP rating: IP54
Kind of display used: LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 245x64x28mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 180g
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 50 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+5780.91 грн
В кошику  од. на суму  грн.
FLUKE-T130 FLK-T90-DTE.pdf Fluke T130 Datasheet (EN).pdf Fluke T130 Datasheet (DE).pdf Fluke T130 Manual (EN).pdf Fluke T130 Manual (DE).pdf
FLUKE-T130
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 27 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+12236.77 грн
В кошику  од. на суму  грн.
FLUKE T130/VDE pVersion=0046&contRep=ZT&docId=005056AB752F1EE2BBEEC2B07D3CF672&compId=FLK-T90-DTE.pdf?ci_sign=dbeb26611662defe11dc0eb630fe1afdb068f1c3 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38133D26B&compId=T110vde_iseng0000.pdf?ci_sign=08b573cadbb76cd86d67ac9c4ffbbccb926c083e pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3C2C38134326B&compId=T110vde_isger0000.pdf?ci_sign=36fcd4b0bf31658852664943b04459582eccfd6f
FLUKE T130/VDE
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Type of tester: electrical
Additional functions: illumination lamp
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
на замовлення 13 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+12399.93 грн
В кошику  од. на суму  грн.
FLUKE-T150 FLK-T90-DTE.pdf Fluke T150 Datasheet (EN).pdf Fluke T150 Datasheet (DE).pdf Fluke T150 Manual (EN).pdf Fluke T150 Manual (DE).pdf
FLUKE-T150
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 51 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+14110.50 грн
В кошику  од. на суму  грн.
FLUKE T150/VDE FLK-T90-DTE.pdf Fluke T150 Datasheet (EN).pdf Fluke T150 Datasheet (DE).pdf T110vde_iseng0000.pdf Fluke T150 Manual (EN).pdf T110vde_isger0000.pdf Fluke T150 Manual (DE).pdf
FLUKE T150/VDE
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
на замовлення 34 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+14117.37 грн
В кошику  од. на суму  грн.
FLUKE-787B FLK-787B.pdf FLK-787B-INS.pdf
Виробник: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+114377.33 грн
В кошику  од. на суму  грн.
FLUKE-789/E 10591-eng.pdf Fluke 789 Datasheet (EN).pdf 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf Fluke 789 Datasheet (DE).pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf Fluke 789 Manual (EN).pdf Fluke 789 Manual (DE).pdf
Виробник: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(1.2% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+135116.30 грн
В кошику  од. на суму  грн.
FLUKE-88-5/A KIT pVersion=0046&contRep=ZT&docId=E1C04C497262E8F1A6F5005056AB5A8F&compId=FLK-88V-A.PDF?ci_sign=deac5a68a71906aed903ea76cba790e957166f0a pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3BDB2B360D26B&compId=88v_____umeng0100.pdf?ci_sign=fa3769da2efe8c3b485834be513e4fa71b470966 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3BDB2B361926B&compId=88v_____umger0100.pdf?ci_sign=bcf025080ea97028c6b64dbeac500a83195e1a36
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Kind of display used: LCD
Temperature measuring range: -200...1090°C
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 0...10000µF
AC current measuring range: 0...10A
DC current measuring range: 0...10A
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
Frequency measuring range: 0...200kHz
Resistance measuring range: 0...50MΩ
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: yes
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+73489.34 грн
В кошику  од. на суму  грн.
FLUKE-279FC/IFLEX pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB52000CACE0C4&compId=Fluke%20279%20FC%20Datasheet%20(EN).pdf?ci_sign=88a37b1b46af8d1be54746442f04159046cddcfb pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB52000CAC80C4&compId=Fluke%20279%20FC%20Datasheet%20(DE).pdf?ci_sign=76a87f396fedd875e6b82acc56be6e7165a6ab35 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB71F0339EC0C4&compId=Fluke%20279%20FC%20Manual%20(EN).pdf?ci_sign=bb8f84e360521c93027d34593a336bbd3be39efe pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB71F0339E60C4&compId=Fluke%20279%20FC%20Manual%20(DE).pdf?ci_sign=dbe2c9776c0738cd475dbbf5658eb91738405579
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Type of meter: digital multimeter with infrared camera
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Interface: Bluetooth
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Resistance measuring range: 600Ω...50MΩ
Diode test: 2V
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Connectors for the country: Europe; Great Britain
Focusing: focus free
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+101366.85 грн
В кошику  од. на суму  грн.
FLK-3000FC pVersion=0046&contRep=ZT&docId=005056AB752F1ED3BADCEC489A36E1EC&compId=FLK-3000FC-DTE.pdf?ci_sign=274b2d1f57869caab82a3312eeeded5d0c04094d pVersion=0046&contRep=ZT&docId=005056AB752F1EE59CCF4429D084611C&compId=6001874B-EN-FC-Reasons-Why-Flyer-w.pdf?ci_sign=da606f061daab71629ac91be27a63bb69521bd00 pVersion=0046&contRep=ZT&docId=005056AB752F1EE59CCF4429D084011C&compId=6001874B-de-FC-Reasons-Why-Flyer-w.pdf?ci_sign=852d87b78b6ca3e900a603555c0cb57305888414 pVersion=0046&contRep=ZT&docId=005056AB752F1EE7A2B33DD17A230749&compId=FLK-3000FC-INS.pdf?ci_sign=5154cb47d651719728a9224ca3d975ac08fcc97e
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
IP rating: IP54
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: compatible Android; Fluke Connect
Type of meter: digital multimeter
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Dimensions (W x H x D): 93x207x48mm
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 340g
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
товару немає в наявності
В кошику  од. на суму  грн.
FLUKE-1587 T 15x7____umeng0200.pdf 15x7____umger0200.pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring accuracy: ±(0.9%+2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+73092.61 грн
В кошику  од. на суму  грн.
FLUKE-123B/EU Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+168408.92 грн
В кошику  од. на суму  грн.
FLUKE-123B/EU/S pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5000FED9A0C4&compId=Fluke%20120B%20Series%20Datasheet%20EN.pdf?ci_sign=a5ebaad24d8d1282c737c335f280bef908081cd8 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5000FED940C4&compId=Fluke%20120B%20Series%20Datasheet%20DE.pdf?ci_sign=4c48c813b22b8330e969d6b1e2543ea3691b30d4 pVersion=0046&contRep=ZT&docId=005056AB752F1EE7A2B33D360FA86749&compId=FLK-123B-INS.pdf?ci_sign=d809318c3150f95924f06ca75781d606784590f9 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6B9A207060C4&compId=Fluke%20120B%20Series%20Manual%20EN.pdf?ci_sign=779552c31c3f407e876b2618621d42b81ee9b42d pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6B9A207000C4&compId=Fluke%20120B%20Series%20Manual%20DE.pdf?ci_sign=6c9ed74c3a5ca94480af1467caeb00836baf16e3
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Kind of display used: colour; LCD TFT 5,7"
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Resistance measuring accuracy: ±(0.6%+5 digit)
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Related items: POM-72941; POM-72942
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Band: 20MHz
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Software: Fluke View
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Dimensions: 259x132x55mm
Number of channels: 2
Display resolution: 640x480
товару немає в наявності
В кошику  од. на суму  грн.
FLUKE-124B/EU Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+205527.12 грн
В кошику  од. на суму  грн.
FLUKE-124B/EU/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+251227.40 грн
В кошику  од. на суму  грн.
FLUKE-125B/EU Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+241375.30 грн
В кошику  од. на суму  грн.
FLUKE-125B/EU/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+291952.24 грн
В кошику  од. на суму  грн.
FLUKE-1587 FC Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf Fluke 1587 FC Manual (EN).pdf 15x7____umeng0200.pdf 15x7____umger0200.pdf Fluke 1587 FC Manual (DE).pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 500V
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Optional equipment: FLK-C25 soft cover
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
на замовлення 14 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+79242.77 грн
В кошику  од. на суму  грн.
FLK-115/TLK-225-1 Fluke 115 Datasheet (english).pdf Manual 114-115-117 (EN).pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
на замовлення 118 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+24009.84 грн
В кошику  од. на суму  грн.
FLUKE-27II/EUR pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A248B43E9B60C7&compId=FLK-27-2.pdf?ci_sign=d0aed22e26219f5838da0547365e065d433266e4 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E60526B&compId=2x_2____umeng0100.pdf?ci_sign=c6d1f2ae200a92ddcdf33d2f539cdea85cd7bbe8 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E61726B&compId=2x_2____umger0100.pdf?ci_sign=65a463467fa490f910365cab7636f5dc01fb1244
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+61024.15 грн
В кошику  од. на суму  грн.
FLUKE-28II/EUR pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F60C4&compId=Fluke%2028-II%20Datasheet%20EN.pdf?ci_sign=badd75d31ad4aff62277d71d5923d927de08a858 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F00C4&compId=Fluke%2028-II%20Datasheet%20DE.pdf?ci_sign=562ef99f3a78d2cc628933285d66eb65030abdd9 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7271A03B00C4&compId=Fluke%2028-II%20Manual%20EN.pdf?ci_sign=0241b174a2cf9fe0368b6013f8efa557d854ced9 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E60526B&compId=2x_2____umeng0100.pdf?ci_sign=c6d1f2ae200a92ddcdf33d2f539cdea85cd7bbe8 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E61726B&compId=2x_2____umger0100.pdf?ci_sign=65a463467fa490f910365cab7636f5dc01fb1244 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7271A03AA0C4&compId=Fluke%2028-II%20Manual%20DE.pdf?ci_sign=a22ce0460ef07b095ef6180642c5c58bed7040e8
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 5 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+60756.22 грн
В кошику  од. на суму  грн.
FLUKE-28IIEX pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F60C4&compId=Fluke%2028-II%20Datasheet%20EN.pdf?ci_sign=badd75d31ad4aff62277d71d5923d927de08a858 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5216056F00C4&compId=Fluke%2028-II%20Datasheet%20DE.pdf?ci_sign=562ef99f3a78d2cc628933285d66eb65030abdd9 pVersion=0046&contRep=ZT&docId=005056AB281E1FD0AA83B4CC651B00E2&compId=28-2EX%20EN%20manual.pdf?ci_sign=73708985684cb6e870d2f337a3f39d8ad2f5afb1 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E60526B&compId=2x_2____umeng0100.pdf?ci_sign=c6d1f2ae200a92ddcdf33d2f539cdea85cd7bbe8 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3AB480E61726B&compId=2x_2____umger0100.pdf?ci_sign=65a463467fa490f910365cab7636f5dc01fb1244
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+145584.11 грн
В кошику  од. на суму  грн.
FLUKE-381 Fluke 381 Datasheet EN.pdf Fluke 381 Datasheet DE.pdf Fluke 381 Manual EN.pdf Fluke 381 Manual DE.pdf
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Body dimensions: 277x88x43mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+63126.29 грн
В кошику  од. на суму  грн.
FLUKE-83-5/EUR pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB57AC98D3C0C4&compId=Fluke%2083V%2087V%20Datasheet%20EN.pdf?ci_sign=6f6761d31c14f198f38c843a8350d3786b45c1ae pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB57AC98D360C4&compId=Fluke%2083V%2087V%20Datasheet%20DE.pdf?ci_sign=27f0c66fffdec0dd1555819d18bca5abc7b390ee pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7B6EBEDFA0C4&compId=fluke%2083%20V%20Manual%20(EN).pdf?ci_sign=63b9521b719932ad3b2195f1f2c865b4ea0e5d2c pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7B6EBEDF40C4&compId=fluke%2083%20V%20Manual%20(DE).pdf?ci_sign=e3545330dfc4d2263435839b27cb3b76fc70ef11
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
IP rating: IP30
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+43514.82 грн
В кошику  од. на суму  грн.
FLUKE-87-5/EUR Fluke 87 V Datasheet (EN).pdf Fluke 87 V Datasheet (DE).pdf Fluke 87 V Manual (EN).pdf Fluke 87 V Manual (DE).pdf
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Type of meter: digital multimeter
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Bargraph: 33 segm. 40x/s
Weight with battery: 600g
Display parameters: (6000/20000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
на замовлення 20 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+45187.61 грн
В кошику  од. на суму  грн.
FLUKE-87V-MAX pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A24B3DB542E0C7&compId=FLK-87VMAX.pdf?ci_sign=f2b600c409bf92e18a0cad187a57c7381571a747
FLUKE-87V-MAX
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+57995.44 грн
В кошику  од. на суму  грн.
FLUKE-87V-MAX/E2 KIT pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A24B3DB542E0C7&compId=FLK-87VMAX.pdf?ci_sign=f2b600c409bf92e18a0cad187a57c7381571a747
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+68495.02 грн
В кошику  од. на суму  грн.
FLK-87VMAX-PVLEAD1
Виробник: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+61396.83 грн
В кошику  од. на суму  грн.
FLUKE-374 FC Fluke 374 FC Datasheet (EN).pdf Fluke 374 FC Datasheet (DE).pdf Fluke 374 FC Manual (EN).pdf Fluke 374 FC Manual (DE).pdf
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC voltage measuring range: 100mV...600V
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+40248.25 грн
В кошику  од. на суму  грн.
FLUKE-375 FC Fluke 375 FC Datasheet (EN).pdf Fluke 375 FC Datasheet (DE).pdf Fluke 375 FC Manual (EN).pdf Fluke 375 FC Manual (DE).pdf
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+47195.30 грн
В кошику  од. на суму  грн.
FLUKE-376 FC Fluke 376 FC Datasheet (EN).pdf Fluke 376 FC Datasheet (DE).pdf Fluke 376 FC Manual (EN).pdf Fluke 376 FC Manual (DE).pdf
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 1...1000µF
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
Resistance measuring range: 0.1...60kΩ
DC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
на замовлення 42 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+51217.55 грн
В кошику  од. на суму  грн.
FLUKE-902 FC pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB580BE9C340C4&compId=Fluke%20902FC%20Datasheet%20EN.pdf?ci_sign=0cd42217de9076fba01030e1ba6d5f6c7b96cf8f pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB580BE9C2E0C4&compId=Fluke%20902FC%20Datasheet%20DE.pdf?ci_sign=3cf54f937eaaf39bb82fe5d2754452a9b52c3c44 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7BD9C80B40C4&compId=Fluke%20902FC%20Manual%20EN.pdf?ci_sign=c0a6f19ea58f6239cfb5166da7101dac3a359f40 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB7BD9C80AE0C4&compId=Fluke%20902FC%20Manual%20DE.pdf?ci_sign=c3e629bc74c7fb197eea0ce758afb7d5519f7be4
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Kind of meter: digital; pincers type
Type of meter: multifunction
Software: Fluke Connect
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Kind of display used: LCD
Illumination: yes
Resistance to: shockproof
True effective value measurement: True RMS AC
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 0.1...200µA
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1.5%+5 digit)
DC voltage measuring range: 100mV...600V
Dimensions: 240x80x40mm
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Weight with battery: 310g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <30Ω
Measuring instruments application: air conditioning; heating industry; ventilation
на замовлення 7 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+31557.99 грн
В кошику  од. на суму  грн.
FLUKE-323 Fluke 32x Datasheet EN.pdf Fluke 32x Datasheet DE.pdf 32x_____umeng0000.pdf Fluke 32x Manual EN.pdf 32x_____umger0000.pdf Fluke 32x Manual DE.pdf
Виробник: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ
DC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 265g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
на замовлення 57 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+12604.31 грн
В кошику  од. на суму  грн.
FLUKE-325 Fluke 32x Datasheet EN.pdf Fluke 32x Datasheet DE.pdf 32x_____umeng0000.pdf Fluke 32x Manual EN.pdf 32x_____umger0000.pdf Fluke 32x Manual DE.pdf
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 10mA...40A; 400A
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
DC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 283g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
на замовлення 61 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+22047.66 грн
В кошику  од. на суму  грн.
FLUKE-378 FC/E FLK-377FC_378FC_EN.pdf
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Type of meter: multifunction
Kind of meter: digital; pincers type
Max. diameter of measured cable: 34mm
Kind of display used: LCD
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring range: 600V; 1kV
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 600V; 1kV
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 0.1...100µF; 1mF
Capacitance measuring accuracy: ±(1%+ 4 digit)
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Continuity test: acoustic indication; <30Ω
Test: diodes
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Pollution degree: 2
Dimensions: 274x86x47mm
Weight with battery: 463g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Interface: Bluetooth
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Software: Fluke Connect
на замовлення 19 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+59339.34 грн
В кошику  од. на суму  грн.
TL71-1
TL71-1
Виробник: FLUKE
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Type of test accessories: test leads
Rated voltage: 1kV
Colour: red and black
Test lead configuration: banana plug 4mm; probe tip
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Wire insulation material: silicone
Kit contents: test leads x2
Cable length: 1.5m
Current rating: 10A
на замовлення 64 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+3477.82 грн
В кошику  од. на суму  грн.
TP40 TestToolCatalog_2006-2007.pdf
TP40
Виробник: FLUKE
Category: Probes - Test Plugs
Description: Set of measuring probes; 60VDC; Kit: test probes x5
Type of test accessories: set of measuring probes
Kit contents: test probes x5
Rated voltage: 60V DC
Related items: FLK-TL222; FLK-TL224
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+5025.23 грн
В кошику  од. на суму  грн.
FLUKE-289/FVF/EUR pVersion=0046&contRep=ZT&docId=005056AB752F1ED39CF0959E175549E4&compId=FLK-289FVF-DTE.PDF?ci_sign=fec92aec968422eb3c6a9cbc254c6e89ecb2e3e8 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5284B9D1A0C4&compId=Fluke%20289%20Datasheet%20EN.pdf?ci_sign=aeb563671b4b8adabf3c3a558ab2df963eb3f624 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB5284B9D140C4&compId=Fluke%20289%20Datasheet%20DE.pdf?ci_sign=8aa946e18ea4e57cab4fd9914bf83e1bc5332993 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3ABD82A22D26B&compId=287_289_umeng0200.pdf?ci_sign=c7a088a38ba19679213c139da66c3a6a3228e2be pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB73517BB9E0C4&compId=Fluke%20287%20%26%20289%20Manual%20EN.pdf?ci_sign=649be04c6557a15b17a70c1226226026ab0b65e4 pVersion=0046&contRep=ZT&docId=005056AB5A8F1ED3A3B3ABD82A23F26B&compId=287_289_umger0200.pdf?ci_sign=3c13dd504be36215deb9e69dffc9c5a600259708 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB73517BB980C4&compId=Fluke%20287%20%26%20289%20Manual%20DE.pdf?ci_sign=0753434097b27284a283cbd7a83fee9c0279c50a
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Type of meter: digital multimeter
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Software: Fluke View
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+86271.40 грн
В кошику  од. на суму  грн.
FLK-289/FVF/IR3000
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Type of meter: digital multimeter
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Software: Fluke View Forms
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+99949.96 грн
В кошику  од. на суму  грн.
I2000 FLEX i2000flxiseng0100.pdf i2000flxisger0100.pdf
Виробник: FLUKE
Category: Meters and AC Clamp Probes
Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
True effective value measurement: True RMS AC
AC current measuring range: 1...20A; 200A; 2kA
Max. diameter of measured cable: 178mm
Cable length: 0.5m
AC current measuring accuracy: ±1%
Bandwidth for AC current measurements: 10Hz...20kHz
Weight with battery: 420g
Max. operating voltage: 600V
Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A)
Display parameters: (3000)
Measurement: AC current
Type of test accessories: AC current clamp adapter
Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Standard equipment: BNC to banana plug adapter
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+36711.18 грн
В кошику  од. на суму  грн.
BP120MH
BP120MH
Виробник: FLUKE
Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; 4.8V; 3000mAh
Type of test accessories: rechargeable battery
Related items: FLK-43B; FLK-123
Capacity: 3Ah
Rated voltage: 4.8V
товару немає в наявності
В кошику  од. на суму  грн.
FLK-TIS55+ 9HZ TIS55+ TIS 75+.pdf
Виробник: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 256x192
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 28° horizontal x 20° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+238049.45 грн
В кошику  од. на суму  грн.
FLK-TIS60+ 9HZ pVersion=0046&contRep=ZT&docId=005056AB90B41EDB90A24CCDA3AB80C7&compId=FLK-TIS60%2B9HZ.pdf?ci_sign=01687eb4792b16585b5871236347996f8899be7e
FLK-TIS60+ 9HZ
Виробник: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 320x240; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 320x240
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 34.1° horizontal x 25.6° vertical
Focusing: FocusFree
IP rating: IP54
Dimensions: 26.7x10.1x14.5mm
Power supply: rechargeable battery Li-Ion 7,4V x2
Measuring instrument features: adjustable display illumination; adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; case; hard case; microSD memory card; power supply; USB cable
Three-dimensional resolution: 1.86mrad
Thermal sensitivity (NETD): <0.045 @ 30°C
Resistance to: fall from 2m height
Measurement: temperature
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V x2
Display resolution: 320x240
Related items: FLK-TI-SBP3
Measuring unit: °C; °F
Interface: Bluetooth; LAN; USB; WiFi
товару немає в наявності
В кошику  од. на суму  грн.
FLK-TIS75+ 9HZ TIS55+ TIS 75+.pdf
Виробник: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 384x288; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 384x288
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 42° horizontal x 30° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; carrying strap; case; hard case; microSD 4GB memory card; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Related items: FLK-TI-SBP3
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; IS3; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+396740.22 грн
В кошику  од. на суму  грн.
C25
C25
Виробник: FLUKE
Category: Bags & Soft Cases
Description: Cover; 218x128x64mm
Related items: FLK-27YEL; FLK-51-2-50HZ; FLK-52-2-50HZ; FLK-53-2-50HZ; FLK-54-2-50HZ; FLK-77-4; FLK-83V; FLK-87V; FLK-88V; FLK-114; FLK-115; FLK-116; FLK-117; FLK-175EGFID; FLK-177EGFID; FLK-179EGFID; FLK-712; FLK-714; FLK-715; FLK-717; FLK-724; FLK-725; FLK-726; FLK-787; FLK-789; FLK-922; FLK-971; FLK-1503; FLK-1507; FLK-1577; FLK-1587; FLK-9040; FLK-9062
Type of test accessories: cover
Dimensions: 218x128x64mm
товару немає в наявності
В кошику  од. на суму  грн.
FLUKE-87-5/E2K/EUR
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-87V; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; FLK-TL224 silicone test leads set; magnetic hanging strap FLK-TOOLPAK; test probes; test probes FLK-AC220 SureGrip
Type of meter: digital multimeter
Related items: POM-4408; POM-5519A; POM-5673B
на замовлення 4 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+53925.10 грн
В кошику  од. на суму  грн.
FLUKE-1587/MDT FC pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB4FDA7B8D60C4&compId=Fluke%201587%20FC%20Datasheet%20(EN).pdf?ci_sign=450e43c0b0eb3f3f0ac52de2c2032089160da3b3 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB4FDA7B8D00C4&compId=Fluke%201587%20FC%20Datasheet%20(DE).pdf?ci_sign=e88ac3f6dd1e3ceb088f550b6f47ca6e604099a0 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6C67640A60C4&compId=Fluke%201587%20FC%20Manual%20(EN).pdf?ci_sign=d5d9ce1986511b4cadc4ef4cf756cbb6e343ded6 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB6C67640A00C4&compId=Fluke%201587%20FC%20Manual%20(DE).pdf?ci_sign=157c50f8ff726c7b66f7f7fcb06ed7ec421ee5c7
Виробник: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+105866.55 грн
В кошику  од. на суму  грн.
FLUKE-705 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB560C292E80C4&compId=Fluke%20705%20Datasheet%20(EN).pdf?ci_sign=7a8af29bf2c4a4b812b13e8d471a08bbe67e98aa pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB79C9BCB520C4&compId=Fluke%20705%20Manual%20(EN).pdf?ci_sign=27cf7ccdb9392edb615f6941a6e4d324b4e68068 pVersion=0046&contRep=ZT&docId=005056AB90B41ED9BAEB79C9BCB4C0C4&compId=Fluke%20705%20Manual%20(DE).pdf?ci_sign=7c72c101d03cab088857b92a1eba64f49a18adbf
Виробник: FLUKE
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Measurement: DC current; DC voltage
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of display used: LCD
Kind of calibrator: loop
Type of meter: calibrator
Power supply: battery 6F22 9V x1
Current source accuracy: ±(0,025% + 2 digits)
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Dimensions: 201x98x52mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
товару немає в наявності
В кошику  од. на суму  грн.
FLK2AC/200-1000VCL Fluke 2AC 200-1000V5 Datasheet (EN).pdf Fluke 2AC 200-1000V5 Datasheet (DE).pdf Fluke 2AC 200-1000V5 Manual (EN).pdf Fluke 2AC 200-1000V5 Manual (DE).pdf
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC
Type of tester: non-contact voltage detector
Measuring instrument features: AutoTest function; battery level indication; optical (LED) indication of detected voltage
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Conform to the norm: CAT IV 1000V; EN 61010
Detected voltage range: 200...1000V AC
на замовлення 62 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна
1+3029.57 грн
В кошику  од. на суму  грн.
Обрати Сторінку:    << Попередня Сторінка ]  1 8 16 24 32 40 48 56 64 72 76 77 78 79 80 81 82 83 84 85 86 88  Наступна Сторінка >> ]