НазваВиробникІнформаціяДоступністьЦіна без ПДВ
ETIMAT P10-DC 1P Z2ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 2A; Poles: 1; Charact: Z; 10kA
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Manufacturer series: ETIMAT P10
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Number of poles: 1
Current rating: 2A
Mechanical durability: 20000 cycles
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
IP rating: IP20
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 1P Z25ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 25A; Poles: 1; Charact: Z; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 25A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: Z
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 1P Z3ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 3A; Poles: 1; Charact: Z; 10kA
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Manufacturer series: ETIMAT P10
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Number of poles: 1
Current rating: 3A
Mechanical durability: 20000 cycles
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
IP rating: IP20
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 1P Z4ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 4A; Poles: 1; Charact: Z; 10kA
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Manufacturer series: ETIMAT P10
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Number of poles: 1
Current rating: 4A
Mechanical durability: 20000 cycles
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
IP rating: IP20
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 1P Z6ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 6A; Poles: 1; Charact: Z; 10kA
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Manufacturer series: ETIMAT P10
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Number of poles: 1
Current rating: 6A
Mechanical durability: 20000 cycles
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
IP rating: IP20
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P B10ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 10A; Poles: 2; Charact: B; 10kA
Characteristics: B
Manufacturer series: ETIMAT P10
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Mounting: for DIN rail mounting
IP rating: IP20
Trade name: MCB
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Number of poles: 2
Current rating: 10A
Rated voltage: 230/400V AC
Mechanical durability: 20000 cycles
Short circuit breaking capacity: 10kA
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P B16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 2; Charact: B; 10kA
Mounting: for DIN rail mounting
Operating temperature: -25...55°C
IP rating: IP20
Current rating: 16A
Mechanical durability: 20000 cycles
Cross section of connecting wires: 1...25mm2
Characteristics: B
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Manufacturer series: ETIMAT P10
Number of poles: 2
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P B20ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 20A; Poles: 2; Charact: B; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 20A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: B
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
Mechanical durability: 20000 cycles
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P B40ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 40A; Poles: 2; Charact: B; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 40A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: B
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P B6ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 6A; Poles: 2; Charact: B; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 6A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: B
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P B63ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 63A; Poles: 2; Charact: B; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 63A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: B
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C1ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 1A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 1A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C10ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 10A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 10A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C13ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 13A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 13A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 2; Charact: C; 10kA
Mounting: for DIN rail mounting
Operating temperature: -25...55°C
IP rating: IP20
Current rating: 16A
Mechanical durability: 20000 cycles
Cross section of connecting wires: 1...25mm2
Characteristics: C
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Manufacturer series: ETIMAT P10
Number of poles: 2
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C2ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 2A; Poles: 2; Charact: C; 10kA
Current rating: 2A
Rated voltage: 230/400V AC
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: C
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Short circuit breaking capacity: 10kA
Manufacturer series: ETIMAT P10
Number of poles: 2
Mechanical durability: 20000 cycles
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C20ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 20A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 20A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C25ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 25A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 25A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C40ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 40A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 40A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C50ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 50A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 50A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P C63ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 63A; Poles: 2; Charact: C; 10kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 63A
Number of poles: 2
Mounting: for DIN rail mounting
Characteristics: C
Short circuit breaking capacity: 10kA
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Manufacturer series: ETIMAT P10
Mechanical durability: 20000 cycles
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P K16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 2; Charact: K; 10kA
Mounting: for DIN rail mounting
Operating temperature: -25...55°C
IP rating: IP20
Current rating: 16A
Mechanical durability: 20000 cycles
Cross section of connecting wires: 1...25mm2
Characteristics: K
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Manufacturer series: ETIMAT P10
Number of poles: 2
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P K20ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 20A; Poles: 2; Charact: K; 10kA
Manufacturer series: ETIMAT P10
Trade name: MCB
Short circuit breaking capacity: 10kA
Number of poles: 2
Current rating: 20A
Mechanical durability: 20000 cycles
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: K
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
IP rating: IP20
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P Z16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 2; Charact: Z; 10kA
Mounting: for DIN rail mounting
Operating temperature: -25...55°C
IP rating: IP20
Current rating: 16A
Mechanical durability: 20000 cycles
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
Trade name: MCB
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Manufacturer series: ETIMAT P10
Number of poles: 2
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P Z2ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 2A; Poles: 2; Charact: Z; 10kA
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Manufacturer series: ETIMAT P10
Number of poles: 2
Current rating: 2A
Mechanical durability: 20000 cycles
Operating temperature: -25...55°C
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT P10-DC 2P Z3ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 3A; Poles: 2; Charact: Z; 10kA
Manufacturer series: ETIMAT P10
Mounting: for DIN rail mounting
Operating temperature: -25...55°C
Trade name: MCB
Rated voltage: 230/400V AC
Short circuit breaking capacity: 10kA
Number of poles: 2
Current rating: 3A
Mechanical durability: 20000 cycles
Cross section of connecting wires: 1...25mm2
Characteristics: Z
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898; IEC EN 60947-2
IP rating: IP20
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 16A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E20ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 20A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 20A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E25ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 25A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 25A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E35ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 35A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 35A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E40ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 40A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 40A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E50ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 50A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 50A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 1P E63ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 63A; Poles: 1; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 63A
Number of poles: 1
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 16A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E20ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 20A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 20A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E25ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 25A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 25A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E32ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 32A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 32A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E35ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 35A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 35A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E40ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 40A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 40A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E50ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 50A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 50A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 3P E63ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 63A; Poles: 3; Charact: E; 25kA
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 3
Current rating: 63A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E16ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 16A; Poles: 4; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 16A
Number of poles: 4
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E20ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 20A; Poles: 4; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 20A
Number of poles: 4
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E25ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 25A; Poles: 4; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 25A
Number of poles: 4
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E35ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 35A; Poles: 4; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 35A
Number of poles: 4
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E40ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 40A; Poles: 4; Charact: E; 25kA
Trade name: MCB
Mounting: for DIN rail mounting
Rated voltage: 230/400V AC
Short circuit breaking capacity: 25kA
Manufacturer series: ETIMAT SM
Number of poles: 4
Current rating: 40A
Operating temperature: -25...55°C
Cross section of connecting wires: 2.5...50mm2
Characteristics: E
Type of protection: circuit breaker
Conform to the norm: IEC EN 60898
IP rating: IP20
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E50ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 50A; Poles: 4; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 50A
Number of poles: 4
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT SM 4P E63ETI POLAMCategory: Circuit Breakers
Description: Circuit breaker; 230/400VAC; Inom: 63A; Poles: 4; Charact: E; 25kA
Type of protection: circuit breaker
Rated voltage: 230/400V AC
Current rating: 63A
Number of poles: 4
Mounting: for DIN rail mounting
Characteristics: E
Short circuit breaking capacity: 25kA
IP rating: IP20
Cross section of connecting wires: 2.5...50mm2
Manufacturer series: ETIMAT SM
Conform to the norm: IEC EN 60898
Trade name: MCB
Operating temperature: -25...55°C
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT T 1P 16AETI POLAMCategory: Installation accessories
Description: Power limiter; Poles: 1; 230/400VAC; Inom: 16A; IP20; ETIMAT T
Manufacturer series: ETIMAT T
Rated voltage: 230/400V AC
Type of protection: power limiter
Conform to the norm: IEC EN 60898
IP rating: IP20
Mounting: for DIN rail mounting
Short circuit breaking capacity: 6kA
Number of poles: 1
Current rating: 16A
Operating temperature: -25...40°C
Cross section of connecting wires: 1...25mm2
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT T 1P+N 10AETI POLAMCategory: Installation accessories
Description: Power limiter; Poles: 1+N; 230/400VAC; Inom: 10A; IP20; ETIMAT T
Manufacturer series: ETIMAT T
Rated voltage: 230/400V AC
Short circuit breaking capacity: 6kA
Mounting: for DIN rail mounting
Conform to the norm: IEC EN 60898
IP rating: IP20
Type of protection: power limiter
Operating temperature: -25...40°C
Cross section of connecting wires: 1...25mm2
Number of poles: 1+N
Current rating: 10A
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT T 1P+N 32AETI POLAMCategory: Installation accessories
Description: Power limiter; Poles: 1+N; 230/400VAC; Inom: 32A; IP20; ETIMAT T
Current rating: 32A
Rated voltage: 230/400V AC
Manufacturer series: ETIMAT T
Operating temperature: -25...40°C
Cross section of connecting wires: 1...25mm2
Type of protection: power limiter
Conform to the norm: IEC EN 60898
IP rating: IP20
Mounting: for DIN rail mounting
Short circuit breaking capacity: 6kA
Number of poles: 1+N
товару немає в наявності
В кошику  од. на суму  грн.
ETIMAT T 3P+N 63AETI POLAMCategory: Installation accessories
Description: Power limiter; Poles: 3+N; 230/400VAC; Inom: 63A; IP20; ETIMAT T
Conform to the norm: IEC EN 60898
Manufacturer series: ETIMAT T
IP rating: IP20
Type of protection: power limiter
Operating temperature: -25...40°C
Cross section of connecting wires: 1...25mm2
Current rating: 63A
Number of poles: 3+N
Rated voltage: 230/400V AC
Short circuit breaking capacity: 6kA
Mounting: for DIN rail mounting
товару немає в наявності
В кошику  од. на суму  грн.
ETIN-M15U-600OmegaDescription: ETIN-M15U-600
Packaging: Bulk
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/AK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal A
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/BK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal B
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/BK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Mounting: outside
Connection: lower terminal K; top terminal B
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Rated voltage: 230/400V AC
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
Manufacturer series: ETITEC A
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/CK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal C
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/DK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal D
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/EK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal E
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/EK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal E
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/FK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal F
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/FK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal F
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/SK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/T-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal T
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/10/TK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 280VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal T
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 280V AC
Protection level at rated imp. current: 1kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 280/5/S-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 5kA; Uoper.max: 280VAC; outside; -40÷80°C
Rated voltage: 230/400V AC
Mounting: outside
Surge arresters features: protection of devices connected by an overhead line
Manufacturer series: ETITEC A
Rated impulse current In (8/20)µs: 5kA
Kind of network: TN; TN-C; TN-S
Operating temperature: -40...80°C
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal S
Type of protection: surge arrester
Max. operating voltage: 280V AC
Protection level at rated imp. current: 0.9kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/A-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal A
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/A-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal A
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/B-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal B
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/B-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal B
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/C-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Max. operating voltage: 440V AC
Surge arresters features: protection of devices connected by an overhead line
Rated impulse current In (8/20)µs: 50kA
Kind of network: TN; TN-C; TN-S
Operating temperature: -40...80°C
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal C
Type of protection: surge arrester
Protection level at rated imp. current: 1.5kV
Mounting: outside
Rated voltage: 230/400V AC
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/C-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal C
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/D-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal D
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/D-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal D
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/DK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 50kA
Max. operating voltage: 440V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.5kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal D
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/E-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal E
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/E-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Mounting: outside
Connection: lower terminal PE; top terminal E
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Rated impulse current In (8/20)µs: 50kA
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/EK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Operating temperature: -40...80°C
Rated impulse current In (8/20)µs: 50kA
Connection: lower terminal K; top terminal E
Application: low-voltage power systems protection
Mounting: outside
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Rated voltage: 230/400V AC
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/FK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 10kA; Uoper.max: 440VAC; outside; -40÷80°C
Mounting: outside
Rated voltage: 230/400V AC
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Manufacturer series: ETITEC A
Rated impulse current In (8/20)µs: 10kA
Kind of network: TN; TN-C; TN-S
Operating temperature: -40...80°C
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal F
Type of protection: surge arrester
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/S-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 10kA; Uoper.max: 440VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 10kA
Max. operating voltage: 440V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.5kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal S
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/T-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal T
Max. operating voltage: 440V AC
Protection level at rated imp. current: 1.5kV
Surge arresters features: protection of devices connected by an overhead line
Rated impulse current In (8/20)µs: 50kA
Mounting: outside
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/10/T-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 440VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 50kA
Max. operating voltage: 440V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.5kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal T
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/5/EK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 440VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 40kA
Max. operating voltage: 440V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.4kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal E
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 440/5/TK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 440VAC; outside; -40÷80°C
Protection level at rated imp. current: 1.4kV
Mounting: outside
Rated voltage: 230/400V AC
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Manufacturer series: ETITEC A
Rated impulse current In (8/20)µs: 40kA
Kind of network: TN; TN-C; TN-S
Operating temperature: -40...80°C
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal T
Type of protection: surge arrester
Max. operating voltage: 440V AC
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/B-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 500VAC; outside; -40÷80°C
Operating temperature: -40...80°C
Manufacturer series: ETITEC A
Connection: lower terminal PE; top terminal B
Mounting: outside
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Rated voltage: 230/400V AC
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.9kV
Rated impulse current In (8/20)µs: 50kA
Application: low-voltage power systems protection
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/BK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 500VAC; outside; -40÷80°C
Mounting: outside
Operating temperature: -40...80°C
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal B
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Max. operating voltage: 500V AC
Rated voltage: 230/400V AC
Protection level at rated imp. current: 1.9kV
Rated impulse current In (8/20)µs: 50kA
Manufacturer series: ETITEC A
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/C-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 500VAC; outside; -40÷80°C
Operating temperature: -40...80°C
Manufacturer series: ETITEC A
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Rated voltage: 230/400V AC
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.9kV
Rated impulse current In (8/20)µs: 50kA
Connection: lower terminal PE; top terminal C
Application: low-voltage power systems protection
Mounting: outside
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/CK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 500VAC; outside; -40÷80°C
Rated voltage: 230/400V AC
Manufacturer series: ETITEC A
Operating temperature: -40...80°C
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.9kV
Rated impulse current In (8/20)µs: 50kA
Mounting: outside
Connection: lower terminal K; top terminal C
Application: low-voltage power systems protection
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Type of protection: surge arrester
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/F-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 500VAC; outside; -40÷80°C
Manufacturer series: ETITEC A
Rated voltage: 230/400V AC
Kind of surge arrester: Type 2
Operating temperature: -40...80°C
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal F
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.9kV
Type of protection: surge arrester
Rated impulse current In (8/20)µs: 50kA
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Mounting: outside
Kind of network: TN; TN-C; TN-S
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/SK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 50kA; Uoper.max: 500VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 50kA
Max. operating voltage: 500V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.9kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal S
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/10/TK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 10kA; Uoper.max: 500VAC; outside; -40÷80°C
Rated voltage: 230/400V AC
Operating temperature: -40...80°C
Rated impulse current In (8/20)µs: 10kA
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal T
Type of protection: surge arrester
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.9kV
Mounting: outside
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Manufacturer series: ETITEC A
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/AK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 40kA
Max. operating voltage: 500V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.7kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal A
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/AK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 40kA
Max. operating voltage: 500V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.7kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal A
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/BK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 40kA
Max. operating voltage: 500V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.7kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal B
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/CK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 40kA
Max. operating voltage: 500V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.7kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal C
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/CK-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 5kA; Uoper.max: 500VAC; outside; -40÷80°C
Mounting: outside
Manufacturer series: ETITEC A
Operating temperature: -40...80°C
Rated voltage: 230/400V AC
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Rated impulse current In (8/20)µs: 5kA
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal C
Type of protection: surge arrester
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.7kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/DK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 5kA; Uoper.max: 500VAC; outside; -40÷80°C
Mounting: outside
Rated voltage: 230/400V AC
Surge arresters features: protection of devices connected by an overhead line
Manufacturer series: ETITEC A
Rated impulse current In (8/20)µs: 5kA
Kind of network: TN; TN-C; TN-S
Operating temperature: -40...80°C
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal D
Type of protection: surge arrester
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.7kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/EK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Rated voltage: 230/400V AC
Manufacturer series: ETITEC A
Operating temperature: -40...80°C
Rated impulse current In (8/20)µs: 40kA
Connection: lower terminal K; top terminal E
Application: low-voltage power systems protection
Mounting: outside
Surge arresters features: protection of devices connected by an overhead line
Type of protection: surge arrester
Kind of network: TN; TN-C; TN-S
Kind of surge arrester: Type 2
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.7kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/F-NOETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Mounting: outside
Rated voltage: 230/400V AC
Surge arresters features: protection of devices connected by an overhead line; thermal disconnector
Manufacturer series: ETITEC A
Rated impulse current In (8/20)µs: 40kA
Kind of network: TN; TN-C; TN-S
Operating temperature: -40...80°C
Kind of surge arrester: Type 2
Application: low-voltage power systems protection
Connection: lower terminal PE; top terminal F
Type of protection: surge arrester
Max. operating voltage: 500V AC
Protection level at rated imp. current: 1.7kV
товару немає в наявності
В кошику  од. на суму  грн.
ETITEC A 500/5/FK-NETI POLAMCategory: Surge Arresters
Description: Surge arrester; Type 2; 40kA; Uoper.max: 500VAC; outside; -40÷80°C
Type of protection: surge arrester
Kind of surge arrester: Type 2
Rated impulse current In (8/20)µs: 40kA
Max. operating voltage: 500V AC
Mounting: outside
Operating temperature: -40...80°C
Surge arresters features: protection of devices connected by an overhead line
Rated voltage: 230/400V AC
Kind of network: TN; TN-C; TN-S
Protection level at rated imp. current: 1.7kV
Manufacturer series: ETITEC A
Application: low-voltage power systems protection
Connection: lower terminal K; top terminal F
товару немає в наявності
В кошику  од. на суму  грн.