Продукція > C.A
| Назва | Виробник | Інформація | Доступність | Ціна | ||||
|---|---|---|---|---|---|---|---|---|
| C.A 1110 | CHAUVIN ARNOUX | CA-1110 Luxmeters | на замовлення 2 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 5001 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; Features: blown fuse indicator; IP40 Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A DC current measuring accuracy: ±2.5% AC current measuring range: 5mA; 50mA; 0.5A; 5A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current; AC voltage; DC current; DC voltage; resistance Measuring instrument features: blown fuse indicator Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Standard equipment: test leads; test probes Battery/ rechargeable battery: battery LR6 AA 1,5V x1 Power supply: battery LR6 AA 1,5V x1 Conform to the norm: CAT III 600V; EN 61010 IP rating: IP40 Body dimensions: 56x105x160mm | на замовлення 4 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 5001 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; Features: blown fuse indicator; IP40 Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A DC current measuring accuracy: ±2.5% AC current measuring range: 5mA; 50mA; 0.5A; 5A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current; AC voltage; DC current; DC voltage; resistance Measuring instrument features: blown fuse indicator Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Standard equipment: test leads; test probes Battery/ rechargeable battery: battery LR6 AA 1,5V x1 Power supply: battery LR6 AA 1,5V x1 Conform to the norm: CAT III 600V; EN 61010 IP rating: IP40 Body dimensions: 56x105x160mm кількість в упаковці: 1 шт | на замовлення 4 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 5003 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV IP rating: IP53 Conform to the norm: CAT III 600V; EN 61010 Standard equipment: test leads; test probes DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A Body dimensions: 56x105x160mm DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC current measuring accuracy: ±2.5% DC current measuring accuracy: ±2.5% AC voltage measuring accuracy: ±2.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV Resistance measuring accuracy: ±10% Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Resistance measuring range: 5...1MΩ Measurement: AC current; AC voltage; DC current; DC voltage; resistance Continuity test: acoustic indication; <50Ω Type of meter: analogue multimeter Measuring instrument features: automatic calibration; blown fuse indicator Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 5003 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV IP rating: IP53 Conform to the norm: CAT III 600V; EN 61010 Standard equipment: test leads; test probes DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A Body dimensions: 56x105x160mm DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC current measuring accuracy: ±2.5% DC current measuring accuracy: ±2.5% AC voltage measuring accuracy: ±2.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV Resistance measuring accuracy: ±10% Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Resistance measuring range: 5...1MΩ Measurement: AC current; AC voltage; DC current; DC voltage; resistance Continuity test: acoustic indication; <50Ω Type of meter: analogue multimeter Measuring instrument features: automatic calibration; blown fuse indicator Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 5005 + MN89 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV Type of meter: analogue multimeter DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV AC voltage measuring accuracy: ±2.5% DC current measuring range: 50µA; 1mA; 10mA; 100mA; 1A; 10A DC current measuring accuracy: ±2.5% AC current measuring range: 3A; 10A; 30A; 100A; 240A AC current measuring accuracy: ±2.5% Resistance measuring range: 5...1MΩ Resistance measuring accuracy: ±10% Continuity test: acoustic indication; <50Ω Measurement: AC current (with current clamps); AC voltage; DC current; DC voltage; resistance Measuring instrument features: automatic calibration; blown fuse indicator Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Standard equipment: CA-MN89 - current clamp; holster; test leads Power supply: battery 6F22 9V x1 Conform to the norm: CAT III 600V; EN 61010 IP rating: IP53 Body dimensions: 56x105x160mm | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 5275 | CHAUVIN ARNOUX | CA-5275 Portable digital multimeters | на замовлення 1 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 5277 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 3 digit) True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring accuracy: ±(1%+2 digit) Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6F22 9V x1 Standard equipment: case; drop-like K-type probe; MultiFIX mounting system; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x190x45mm Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX/DIF/AVG function; MIN/MAX function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: battery 6F22 9V x1 Illumination: yes Bargraph: 61 segm. Test: diodes Resistance to: fall from 1m height Temperature measuring range (with K-type thermocouple): -59.6...1200°C Temperature measurement accuracy: ±(0.5% + 2°C) Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz Producer guarantee (months): 36 Bandwidth for AC current measurements: 40Hz...1kHz Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 5292 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Resistance measuring accuracy: ±(0.07%+8 digit) Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes Event memory: 10000 Test: diodes Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Temperature measuring range (with K-type thermocouple): -40...1200°C Temperature measurement accuracy: ±0.1% Producer guarantee (months): 36 Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 5292-BT | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s Type of meter: digital multimeter Interface: Bluetooth; USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Resistance measuring accuracy: ±(0.07%+8 digit) Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes Event memory: 30000 Test: diodes Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Temperature measuring range (with K-type thermocouple): -40...1200°C Temperature measurement accuracy: ±0.1% Producer guarantee (months): 36 Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 5293 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Resistance measuring accuracy: ±(0.07%+8 digit) Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes Event memory: 10000 Test: diodes Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Temperature measuring range (with K-type thermocouple): -40...1200°C Temperature measurement accuracy: ±0.1% Producer guarantee (months): 36 Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 6133 LAUNCH KIT | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Continuity test: <10Ω Type of meter: appliance meter Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function Interface: Bluetooth Power supply: rechargeable battery Ni-MH AA x6 Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Software: dedicated mobile app IP rating: IP54 Kind of display used: LCD Bargraph: yes Illumination: yes AC voltage measuring range: 2...550V Resistance measuring range: 1...10Ω; 100kΩ Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) Frequency measuring range: 30...1000Hz Loop impedance measuring range: 100mΩ...1Ω; 400Ω Dimensions: 223x126x70mm Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ AC voltage measuring accuracy: ±(1% + 2 digit) Measurement memory: 2970 Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 6133 LAUNCH KIT | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Continuity test: <10Ω Type of meter: appliance meter Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function Interface: Bluetooth Power supply: rechargeable battery Ni-MH AA x6 Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Software: dedicated mobile app IP rating: IP54 Kind of display used: LCD Bargraph: yes Illumination: yes AC voltage measuring range: 2...550V Resistance measuring range: 1...10Ω; 100kΩ Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) Frequency measuring range: 30...1000Hz Loop impedance measuring range: 100mΩ...1Ω; 400Ω Dimensions: 223x126x70mm Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ AC voltage measuring accuracy: ±(1% + 2 digit) Measurement memory: 2970 Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 6418 | CHAUVIN ARNOUX | CA-6418 Earth Resistance Meter | на замовлення 1 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 6503 | CHAUVIN ARNOUX | CA-6503 Insulation Resistance Meters | на замовлення 1 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 6524 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Body dimensions: 211x108x60mm Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Type of meter: insulation resistance IP rating: IP54 Kind of display used: LCD Bargraph: yes AC voltage measuring range: 300mV...400V; 700V DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Resistance measuring accuracy: ±(3%+2 digit) Continuity test: <10Ω; <100Ω Test voltage: 50V; 100V; 250V; 500V; 1kV Measurement memory: 300 Weight without batteries: 850g Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ Display parameters: (4000) Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Standard equipment: carrying case; crocodile clip; test leads; test probe x1 | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 6526 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Kind of display used: LCD Bargraph: yes Capacitance measuring range: 0.1...400nF; 4µF; 10µF Body dimensions: 211x108x60mm AC voltage measuring range: 300mV...400V; 700V DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Resistance measuring accuracy: ±(3%+2 digit) Continuity test: <10Ω; <100Ω Test voltage: 50V; 100V; 250V; 500V; 1kV Weight without batteries: 850g Measurement memory: 1300 Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ Display parameters: (4000) Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Power supply: battery LR6 AA 1,5V x6 Interface: Bluetooth Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Software: included Type of meter: insulation resistance IP rating: IP54 | на замовлення 1 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 6526 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Kind of display used: LCD Bargraph: yes Capacitance measuring range: 0.1...400nF; 4µF; 10µF Body dimensions: 211x108x60mm AC voltage measuring range: 300mV...400V; 700V DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) Insulation resistance measuring accuracy: ±(3% + 2digit) Resistance measuring accuracy: ±(3%+2 digit) Continuity test: <10Ω; <100Ω Test voltage: 50V; 100V; 250V; 500V; 1kV Weight without batteries: 850g Measurement memory: 1300 Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ Display parameters: (4000) Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Power supply: battery LR6 AA 1,5V x6 Interface: Bluetooth Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Software: included Type of meter: insulation resistance IP rating: IP54 кількість в упаковці: 1 шт | на замовлення 1 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 702 | CHAUVIN ARNOUX | CA-702 Portable digital multimeters | на замовлення 2 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 703 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V Type of meter: digital multimeter Measurement: AC current; AC voltage; continuity; DC current; DC voltage; resistance Kind of display used: LCD Display parameters: (1999) DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V DC voltage measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring range: 2V; 20V; 200V; 600V AC voltage measuring accuracy: ±(1% + 8 digit) DC current measuring range: 0.2mA; 2mA; 20mA; 200mA DC current measuring accuracy: ±(2% + 8 digit) AC current measuring range: 0.2mA; 2mA; 20mA; 200mA AC current measuring accuracy: ±(2.5% + 10 digit) Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ Resistance measuring accuracy: ±(0.08%+5 digit) Diode test: 1mA @1.5V Continuity test: acoustic indication; <60Ω Power supply: battery LR03 AAA 1,5V x2 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 55x104x32.5mm Measuring instrument features: automatic power-off; autoranging; contactless voltage detector; HOLD function; low battery indicator; permanently connected test leads; pocket size Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Standard equipment: fixed test leads Additional functions: torch | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 703 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V Type of meter: digital multimeter Measurement: AC current; AC voltage; continuity; DC current; DC voltage; resistance Kind of display used: LCD Display parameters: (1999) DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V DC voltage measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring range: 2V; 20V; 200V; 600V AC voltage measuring accuracy: ±(1% + 8 digit) DC current measuring range: 0.2mA; 2mA; 20mA; 200mA DC current measuring accuracy: ±(2% + 8 digit) AC current measuring range: 0.2mA; 2mA; 20mA; 200mA AC current measuring accuracy: ±(2.5% + 10 digit) Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ Resistance measuring accuracy: ±(0.08%+5 digit) Diode test: 1mA @1.5V Continuity test: acoustic indication; <60Ω Power supply: battery LR03 AAA 1,5V x2 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 55x104x32.5mm Measuring instrument features: automatic power-off; autoranging; contactless voltage detector; HOLD function; low battery indicator; permanently connected test leads; pocket size Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Standard equipment: fixed test leads Additional functions: torch кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 732 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 195÷265VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 195...265V AC Conform to the norm: CAT III 1000V; EN 61010 Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 IP rating: IP40 Additional functions: torch кількість в упаковці: 1 шт | на замовлення 2 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 732 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 195÷265VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 195...265V AC Conform to the norm: CAT III 1000V; EN 61010 Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 IP rating: IP40 Additional functions: torch | на замовлення 2 шт: термін постачання 21-30 дні (днів) |
| ||||
| C.A 745N | CHAUVIN ARNOUX | CA-745N Indicators, Voltage & Continuity Testers | на замовлення 1 шт: термін постачання 7-14 дні (днів) |
| ||||
| C.A 755 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC voltage; capacitance; continuity; DC voltage; resistance Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: test probes Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Conform to the norm: CAT III 600V; EN 61010 Resistance to: fall from 2m height IP rating: IP54 Dimensions (W x H x D): 180x52x45mm | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 757 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) AC current measuring range: 500mA...30A; 300A AC current measuring accuracy: ±(3% + 5 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; resistance Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: probe MiniFlex; test probes; Velcro strap Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Conform to the norm: CAT III 600V; EN 61010 Resistance to: fall from 2m height IP rating: IP54 Dimensions (W x H x D): 180x52x45mm | товару немає в наявності | В кошику од. на суму грн. | ||||
| C.A 8335 MN93A | Chauvin Arnoux (Metrix) | на замовлення 1 шт: термін постачання 5 дні (днів) | В кошику од. на суму грн. | |||||
| C.A 8336 | CHAUVIN ARNOUX | Category: Power Quality Analyzers Description: Meter: power quality analyser; colour,LCD TFT; Interface: USB Interface: USB Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; IEC 61000-4-30 Kind of display used: colour; LCD TFT IP rating: IP53 Software: Power Analyser Transfer Type of meter: power quality analyser Power supply: rechargeable battery Ni-MH x1 Kind of network: three-phase Dimensions: 240x180x55mm Number of inputs: 9 Producer guarantee (months): 36 Supply voltage: 100...240V AC Display resolution: 320x240 Standard equipment: 12-colour set to mark leads and inputs; carrying case; crocodile clip x5; mains cable; manual (CD); screen protector preventing scratching (set); test leads ( 5pcs.); USB cable Measuring instrument features: automatic recognition various current detectors; more than 450 recordable values with the required parameters and graphic displays; operation of several modes in parallel; possibility of viewing the data during a campaign; up to 40 alarms can be set simultaneously Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (option); DC voltage; distorting power; energy; harmonics; inrush current; K factor for transformers; reactive power; short or long-term flicker | товару немає в наявності | В кошику од. на суму грн. |