Продукція > C.A
| Назва | Виробник | Інформація | Доступність | Ціна без ПДВ | ||
|---|---|---|---|---|---|---|
| C.A 1725 | CHAUVIN ARNOUX | Category: Tachometers Description: Tachometer; LCD; 60÷100000rpm; 216x72x47mm; IP51; Illumin: yes Type of meter: tachometer Kind of display used: LCD Measuring range: 60...100000rpm Body dimensions: 216x72x47mm Power supply: battery 9V x1 Measuring instrument features: MIN/MAX function; programmable alarm thresholds Standard equipment: FRB F adapter; hard case; reflective tape; user's manual Measurement: rpm velocity (mechanical); rpm velocity (optical) IP rating: IP51 Battery/ rechargeable battery: battery 9V x1 Illumination: yes Bargraph: yes; 42 segm. | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 1727 | CHAUVIN ARNOUX | Category: Tachometers Description: Tachometer; LCD; 60÷100000rpm; 216x72x47mm; IP51; Interface: USB Type of meter: tachometer Kind of display used: LCD Measuring range: 60...100000rpm Body dimensions: 216x72x47mm Power supply: battery 9V x1 Measuring instrument features: MIN/MAX function; programmable alarm thresholds Standard equipment: FRB F adapter; hard case; reflective tape; user's manual Measurement: rpm velocity (mechanical); rpm velocity (optical) IP rating: IP51 Interface: USB Battery/ rechargeable battery: battery 9V x1 Measurement memory: 4000 Software: Tachograph Illumination: yes Bargraph: yes; 42 segm. | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 1954 P01651904 | CHAUVIN ARNOUX | Category: Infrared Cameras - Others Description: Infrared camera; LCD 2,8"; 160x120; 9Hz; -20÷250°C; IP54; 4.1mrad Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual Related items: CA-F407; CA-F607 Resistance to: fall from 2m height Focusing: focus free Software: included Type of meter: infrared camera IP rating: IP54 Kind of display used: LCD 2,8" Battery/ rechargeable battery: rechargeable battery Ni-MH x4 Power supply: rechargeable battery Ni-MH x4 Temperature measuring range: -20...250°C Three-dimensional resolution: 4.1mrad Body dimensions: 225x125x83mm Thermal sensitivity (NETD): ≤0.08 @ 30°C Temperature measurement accuracy: ±2%; ±2°C Refresh rate: 9Hz Field of observation: 38° horizontal x 28° vertical Camera resolution: 160x120 Weight with battery: 700g Emissivity value: 0,05...1 Interface: Bluetooth; USB Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 5001 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; Features: blown fuse indicator; IP40 Body dimensions: 56x105x160mm Battery/ rechargeable battery: battery LR6 AA 1,5V x1 Standard equipment: test leads; test probes Conform to the norm: CAT III 600V; EN 61010 IP rating: IP40 DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV AC current measuring range: 5mA; 50mA; 0.5A; 5A DC current measuring accuracy: ±2.5% DC voltage measuring accuracy: ±1.5% AC voltage measuring accuracy: ±2.5% AC current measuring accuracy: ±2.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV Resistance measuring accuracy: ±10% Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Resistance measuring range: 5...1MΩ Measurement: AC current; AC voltage; DC current; DC voltage; resistance Continuity test: acoustic indication; <50Ω Type of meter: analogue multimeter Measuring instrument features: blown fuse indicator Power supply: battery LR6 AA 1,5V x1 | на замовлення 3 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 5003 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A Body dimensions: 56x105x160mm DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% DC current measuring accuracy: ±2.5% AC voltage measuring accuracy: ±2.5% AC current measuring accuracy: ±2.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV Resistance measuring accuracy: ±10% Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Measurement: AC current; AC voltage; DC current; DC voltage; resistance Resistance measuring range: 5...1MΩ Continuity test: acoustic indication; <50Ω Type of meter: analogue multimeter Measuring instrument features: automatic calibration; blown fuse indicator Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Standard equipment: test leads; test probes Conform to the norm: CAT III 600V; EN 61010 IP rating: IP53 | на замовлення 1 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 5005 + MN89 | CHAUVIN ARNOUX | Category: Analog Multimeters Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV DC current measuring range: 50µA; 1mA; 10mA; 100mA; 1A; 10A AC current measuring range: 3A; 10A; 30A; 100A; 240A Body dimensions: 56x105x160mm DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV DC voltage measuring accuracy: ±1.5% DC current measuring accuracy: ±2.5% AC voltage measuring accuracy: ±2.5% AC current measuring accuracy: ±2.5% AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV Resistance measuring accuracy: ±10% Producer guarantee (months): 36 Input impedance for AC voltage: 6.32kΩ/V Input impedance for DC voltage measurement: 20kΩ/V Measurement: AC current (with current clamps); AC voltage; DC current; DC voltage; resistance Resistance measuring range: 5...1MΩ Continuity test: acoustic indication; <50Ω Type of meter: analogue multimeter Measuring instrument features: automatic calibration; blown fuse indicator Power supply: battery 6F22 9V x1 Standard equipment: CA-MN89 - current clamp; holster; test leads Conform to the norm: CAT III 600V; EN 61010 IP rating: IP53 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 5233 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) DC current measuring range: 6A; 10A; 15A < 60s DC current measuring accuracy: ±(1.5% + 3 digit) AC current measuring range: 6A; 10A; (15A <60s) AC current measuring accuracy: ±(2% + 3 digit) True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF Capacitance measuring accuracy: ±(3.5%+ 4 digit) Frequency measuring range: 10...3000Hz Frequency measuring accuracy: ±0.5% Resistance measuring accuracy: ±(0.3%+4 digit) Continuity test: acoustic indication Power supply: battery 6LR61 9V x1 Standard equipment: banana plug - K plug adapter; drop-like K-type probe; test leads Conform to the norm: CAT III 600V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 75x155x75mm Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/REL function Battery/ rechargeable battery: battery 6LR61 9V x1 Illumination: yes Resistance to: fall from 1m height Test: diodes Duty cycle factor: 0.1...99.9% Temperature measurement accuracy: ±(2% + 5°C) Sampling: 3x/s Producer guarantee (months): 12 Bandwidth for AC current measurements: 40Hz...1kHz Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz Bargraph: 61 segm. Temperature measuring range (with K-type thermocouple): -20...760°C IP rating: IP54 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 5273 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1.2% + 3 digit) DC current measuring range: 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6A; 10A AC current measuring accuracy: ±(1% + 3 digit) True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring accuracy: ±(1%+2 digit) Continuity test: acoustic indication Power supply: battery 6F22 9V x1 Standard equipment: drop-like K-type probe; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 90x190x45mm Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; low input impedance function (LoZ); low-pass filter; MIN/MAX function Battery/ rechargeable battery: battery 6F22 9V x1 Bandwidth for AC current measurements: 40Hz...1kHz Sampling: 5x/s Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Test: diodes Resistance to: fall from 1m height IP rating: IP54 Illumination: yes Temperature measuring range (with K-type thermocouple): -59.6...1200°C Temperature measurement accuracy: ±(0.5% + 2°C) Producer guarantee (months): 36 Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...3kHz | на замовлення 1 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 5275 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 3 digit) True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring accuracy: ±(1%+2 digit) Continuity test: acoustic indication Power supply: battery 6F22 9V x1 Standard equipment: case; MultiFIX mounting system; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 90x190x45mm Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX function; selection of AC or AC+DC measurement Battery/ rechargeable battery: battery 6F22 9V x1 Bandwidth for AC current measurements: 40Hz...1kHz Sampling: 5x/s Test: diodes Resistance to: fall from 1m height IP rating: IP54 Illumination: yes Producer guarantee (months): 36 Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz | на замовлення 1 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 5277 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 61 segm. Sampling: 5x/s DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.8% + 2 digit) AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 3 digit) Bandwidth for AC current measurements: 40Hz...1kHz True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF Capacitance measuring accuracy: ±(1%+ 5 digit) Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz Frequency measuring accuracy: ±(0.1%+2 digit) Temperature measurement accuracy: ±(0.5% + 2°C) Temperature measuring range (with K-type thermocouple): -59.6...1200°C Resistance measuring accuracy: ±(1%+2 digit) Test: diodes Continuity test: acoustic indication IP rating: IP54 Power supply: battery 6F22 9V x1 Standard equipment: case; drop-like K-type probe; MultiFIX mounting system; test leads; test probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Resistance to: fall from 1m height Dimensions (W x H x D): 90x190x45mm Producer guarantee (months): 36 Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX/DIF/AVG function; MIN/MAX function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: battery 6F22 9V x1 Illumination: yes | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 5292 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Resistance measuring accuracy: ±(0.07%+8 digit) Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes Event memory: 10000 Test: diodes Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Temperature measuring range (with K-type thermocouple): -40...1200°C Temperature measurement accuracy: ±0.1% Producer guarantee (months): 36 Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 5292-BT | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s Type of meter: digital multimeter Interface: Bluetooth; USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Resistance measuring accuracy: ±(0.07%+8 digit) Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes Event memory: 30000 Test: diodes Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Temperature measuring range (with K-type thermocouple): -40...1200°C Temperature measurement accuracy: ±0.1% Producer guarantee (months): 36 Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 5293 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS Type of meter: digital multimeter Interface: USB Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature Kind of display used: colour; LCD Display parameters: (100000) DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.03% + 8 digit) AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s DC current measuring accuracy: ±(0.08% + 8 digit) AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s) True effective value measurement: True RMS Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz Temperature measuring range: -200...800°C Resistance measuring accuracy: ±(0.07%+8 digit) Continuity test: acoustic indication IP rating: IP67 Power supply: rechargeable battery Ni-MH AA 1,2V x4 Standard equipment: case; mains battery charger; test leads; test probes; USB cable Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Dimensions (W x H x D): 90x169x47.1mm Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4 Software: included Illumination: yes Event memory: 10000 Test: diodes Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K Temperature measuring range (with K-type thermocouple): -40...1200°C Temperature measurement accuracy: ±0.1% Producer guarantee (months): 36 Sampling: 5x/s | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6113 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD 5,7"; 320x240; IP53; Illumin: yes Type of meter: appliance meter Kind of display used: LCD 5,7" Display resolution: 320x240 Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ Earthing resistance measuring accuracy: ±(2% + 2 digit) Continuity test: acoustic indication; optical indication RCD test: AC, A and F-type RCDs; general purpose Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω Measurement: AC current (with current clamps); AC voltage; continuity; DC voltage; earthing resistance; frequency; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop Insulation resistance measuring ranges: 0.01MΩ...2GΩ Test voltage: 50V; 100V; 250V; 500V; 1kV IP rating: IP53 Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1 Power supply: rechargeable battery Ni-MH x1 Measuring instrument features: long operating time up to 24 hours; programmable alarm thresholds; test leads resistance compensation Body dimensions: 280x190x128mm Weight with battery: 2.2kg Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes Optional equipment: CA-C177; CA-C177A; CA-MN77 Battery/ rechargeable battery: rechargeable battery Ni-MH x1 Illumination: yes Loop impedance measuring accuracy: ±(5% + 2 digit) | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6133 | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function Interface: Bluetooth Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Software: dedicated mobile app Power supply: rechargeable battery Ni-MH AA x6 IP rating: IP54 Kind of display used: LCD Illumination: yes Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Bargraph: yes Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Loop impedance measuring range: 100mΩ...1Ω; 400Ω Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions: 223x126x70mm Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 1...10Ω; 100kΩ AC voltage measuring range: 2...550V Continuity test: <10Ω Frequency measuring range: 30...1000Hz Measurement memory: 2970 Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Type of meter: appliance meter | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6133 LAUNCH KIT | CHAUVIN ARNOUX | Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function Interface: Bluetooth Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Software: dedicated mobile app Power supply: rechargeable battery Ni-MH AA x6 IP rating: IP54 Kind of display used: LCD Illumination: yes Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Bargraph: yes Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Loop impedance measuring range: 100mΩ...1Ω; 400Ω Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions: 223x126x70mm Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 1...10Ω; 100kΩ AC voltage measuring range: 2...550V Continuity test: <10Ω Frequency measuring range: 30...1000Hz Measurement memory: 2970 Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Type of meter: appliance meter | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6418 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; Øcable: 32mm; OLED; IP40 Type of meter: grounding resistance Max. diameter of measured cable: 32mm Kind of display used: OLED Earthing resistance measuring range: 10...100mΩ; 1Ω; 50Ω; 150Ω; 250Ω; 450Ω; 650Ω; 1.2kΩ Earthing resistance measuring accuracy: ±(1.5% + 0.01Ω) AC current measuring range: 10mA; 100mA; 300mA; 3A; 20A AC current measuring accuracy: ±(2% + 200µA) Body dimensions: 300x106x56mm Weight with battery: 1.2kg Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 150V; CAT IV 100V; EN 61010 Standard equipment: hard case; wristbands Measuring instrument features: AUTO HOLD; calibration function; manual HOLD function or automatic PRE-HOLD; measurements on wires and rectangular bars; programmable alarm thresholds: current, impedance Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Measurement memory: 300 IP rating: IP40 Related items: CA-P01122301 | на замовлення 1 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 6422 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; LCD; 0.05÷50kΩ; IP65; Illumin: yes Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Power supply: battery LR6 AA 1,5V x6 Conform to the norm: CAT IV 600V; EN 61010; EN 61557 Type of meter: grounding resistance IP rating: IP65 Kind of display used: LCD Standard equipment: user's manual Illumination: yes Body dimensions: 223x126x70mm Earthing resistance measuring accuracy: ±(2% + 1 digit) Earthing resistance measuring range: 0.05...50kΩ Weight with battery: 1kg | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6424 | CHAUVIN ARNOUX | Category: Earth Resistance Meter Description: Meter: grounding resistance; LCD; 0.05÷50kΩ; IP65; Illumin: yes Type of meter: grounding resistance Kind of display used: LCD Earthing resistance measuring range: 0.05...50kΩ Earthing resistance measuring accuracy: ±(2% + 1 digit) IP rating: IP65 Body dimensions: 223x126x70mm Weight with battery: 1kg Power supply: rechargeable battery Ni-MH AA x6 Conform to the norm: CAT IV 600V; EN 61010; EN 61557 Standard equipment: carrying case; mains cable; power supply; user's manual Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Illumination: yes | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6511 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; analogue; VAC: 0÷600V Type of meter: insulation resistance Kind of display used: analogue Measurement: AC voltage; insulation resistance AC voltage measuring range: 0...600V Test voltage: 500V Conform to the norm: CAT III 600V; EN 61010 Standard equipment: 1 crocodile clips; test leads ( 2pcs.); test probe x1; user's manual Power supply: battery AA 1,5V x4 Body dimensions: 167x106x55mm Insulation resistance measuring ranges: 1GΩ Battery/ rechargeable battery: battery AA 1,5V x4 Continuity test: -10Ω...10Ω | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6513 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; analogue; R range: 0÷1kΩ Measurement: AC voltage; insulation resistance; resistance Kind of display used: analogue Battery/ rechargeable battery: battery AA 1,5V x4 Power supply: battery AA 1,5V x4 Conform to the norm: CAT III 600V; EN 61010 Type of meter: insulation resistance Continuity test: -10Ω...10Ω AC voltage measuring range: 0...600V Resistance measuring range: 0...1kΩ Body dimensions: 167x106x55mm Test voltage: 250V; 500V; 1kV Insulation resistance measuring ranges: 1GΩ Standard equipment: 1 crocodile clips; test leads ( 2pcs.); test probe x1; user's manual | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6524 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Type of meter: insulation resistance Kind of display used: LCD Body dimensions: 211x108x60mm Power supply: battery LR6 AA 1,5V x6 Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Measurement memory: 300 IP rating: IP54 Bargraph: yes AC voltage measuring range: 300mV...400V; 700V DC voltage measuring range: 300mV...400V; 700V DC voltage measuring accuracy: ±(3% + 2 digit) Resistance measuring accuracy: ±(3%+2 digit) Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ Insulation resistance measuring accuracy: ±(3% + 2digit) Test voltage: 50V; 100V; 250V; 500V; 1kV Weight without batteries: 850g Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ Display parameters: (4000) Continuity test: <10Ω; <100Ω | на замовлення 1 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 6526 | CHAUVIN ARNOUX | Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V Software: included IP rating: IP54 Kind of display used: LCD Bargraph: yes Capacitance measuring range: 0.1...400nF; 4µF; 10µF AC voltage measuring range: 300mV...400V; 700V DC voltage measuring range: 300mV...400V; 700V Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ DC voltage measuring accuracy: ±(3% + 2 digit) Resistance measuring accuracy: ±(3%+2 digit) Body dimensions: 211x108x60mm Insulation resistance measuring accuracy: ±(3% + 2digit) Test voltage: 50V; 100V; 250V; 500V; 1kV Weight without batteries: 850g Measurement memory: 1300 Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ Display parameters: (4000) Continuity test: <10Ω; <100Ω Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Interface: Bluetooth Standard equipment: carrying case; crocodile clip; test leads; test probe x1 Type of meter: insulation resistance | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 6609 | CHAUVIN ARNOUX | Category: Phase Sequence Indicators Description: Tester: phase sequence; LED; Freq: 15÷400Hz; IP40 Type of tester: phase sequence Kind of display used: LED Phase-to-phase voltage range for phase sequence indication: 40...600V AC Operating frequency: 15...400Hz IP rating: IP40 Body dimensions: 130x69x32mm Weight with battery: 170g Power supply: battery 9V x1 Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7 Measurement: motor's rotation direction; phase sequence Measuring instrument features: non-contact determination of rotation field direction; voltage indicator individual for each phase Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.) | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 7028 | CHAUVIN ARNOUX | Category: LAN and Telephone Networks Testers Description: Tester: LAN wiring; LCD; 0÷40°C; 165x90x37mm; Illumin: yes Measuring instrument features: automatic power-off; identyfication of pairs; low battery indicator; testing and identifying up to 9 links; voltage presence indicator; wiring schemes: TIA 568A/B, USOC & ISDN Power supply: battery LR6 AA 1,5V x4 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Measurement: cable length; continuity Test: cables FTP; cables SSTP; cables STP; cables UTP Related items: CA-P01101994; CA-P01101995 Detection: discontinuities and short circuits in conductors; place of cable failure; reversed connection; screening continuity; split pairs Type of tester: LAN wiring Kind of display used: LCD Illumination: yes Operating temperature: 0...40°C Dimensions: 165x90x37mm Standard equipment: case; identifier; RJ45 connection cables Conform to the norm: EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-6; EN 61326-1; IEC 61010-1 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 732 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 195÷265VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 195...265V AC Additional functions: torch Conform to the norm: CAT III 1000V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation IP rating: IP40 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 | на замовлення 1 шт: термін постачання 14-30 дні (днів) |
| ||
| C.A 742 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V IP rating: IP65 Body dimensions: 163x64x40mm Power supply: battery LR03 AAA 1,5V x2 Standard equipment: carrying strap; test lead; test probe x1 Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LEDs Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Weight with battery: 210g Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication; <100Ω Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 751 | CHAUVIN ARNOUX | Category: Accessories - Others Description: Adapter; 95x50x38mm; IP20 Type of test accessories: adapter Dimensions: 95x50x38mm IP rating: IP20 Related items: CA-742; CA-762 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 755 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Kind of display used: LCD Illumination: yes DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Resistance measuring accuracy: ±(3%+3 digit) Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Test: diodes Continuity test: acoustic indication; <30Ω Measurement: AC voltage; capacitance; continuity; DC voltage; resistance Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Standard equipment: test probes Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Conform to the norm: CAT III 600V; EN 61010 Resistance to: fall from 2m height IP rating: IP54 Dimensions (W x H x D): 180x52x45mm | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 757 | CHAUVIN ARNOUX | Category: Portable digital multimeters Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54 Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; resistance Kind of display used: LCD DC voltage measuring range: 3V; 30V; 300V; 1kV DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring range: 3V; 30V; 300V; 1kV AC voltage measuring accuracy: ±(3% + 4 digit) AC current measuring range: 500mA...30A; 300A AC current measuring accuracy: ±(3% + 5 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF Capacitance measuring accuracy: ±(5%+ 5 digit) Resistance measuring accuracy: ±(3%+3 digit) Test: diodes Continuity test: acoustic indication; <30Ω IP rating: IP54 Power supply: battery LR03 AAA 1,5V x2 Standard equipment: probe MiniFlex; test probes; Velcro strap Conform to the norm: CAT III 600V; EN 61010 Resistance to: fall from 2m height Dimensions (W x H x D): 180x52x45mm Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Illumination: yes | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 762 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; 50÷690VAC; 16.66÷800Hz; IP65 IP rating: IP65 Body dimensions: 163x64x40mm Power supply: battery LR03 AAA 1,5V x2 Standard equipment: carrying strap; test lead; test probe x1 Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LEDs Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 50...690V AC Weight with battery: 210g Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication; 100Ω...2kΩ; 2kΩ...60kΩ; 60kΩ...300kΩ Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 762 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; 50÷690VAC; 16.66÷800Hz; IP65 IP rating: IP65 Body dimensions: 163x64x40mm Power supply: battery LR03 AAA 1,5V x2 Standard equipment: carrying strap; IP2X test probes; test lead Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LEDs Bandwidth for AC voltage measurements: 16.66...800Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 50...690V AC Weight with battery: 210g Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication; 100Ω...2kΩ; 2kΩ...60kΩ; 60kΩ...300kΩ Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 771 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; 50÷1000VAC; 40÷65Hz; IP65; RCD test: 30mA IP rating: IP65 Body dimensions: 228x60x39mm Power supply: battery LR6 AA 1,5V x2 Standard equipment: test probe x1; Velcro strap Conform to the norm: CAT IV 1000V; EN 61010; EN 61243-3; IEC 61326-1 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LEDs Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV Phase-to-phase voltage range for phase sequence indication: 50...1000V AC Weight with battery: 350g Additional functions: torch RCD test: 30mA Measuring instrument features: AutoTest function; phase sequence indication; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication Battery/ rechargeable battery: battery LR6 AA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 771 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs; 50÷1000VAC; 40÷65Hz; IP65; RCD test: 30mA IP rating: IP65 Body dimensions: 228x60x39mm Power supply: battery LR6 AA 1,5V x2 Standard equipment: IP2X test probes; Velcro strap Conform to the norm: CAT IV 1000V; EN 61010; EN 61243-3; IEC 61326-1; NF C 18-510 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LEDs Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV Phase-to-phase voltage range for phase sequence indication: 50...1000V AC Weight with battery: 350g Additional functions: torch RCD test: 30mA Measuring instrument features: AutoTest function; phase sequence indication; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication Battery/ rechargeable battery: battery LR6 AA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 773 | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65 IP rating: IP65 Body dimensions: 228x60x39mm Power supply: battery LR6 AA 1,5V x2 Standard equipment: test probe x1; Velcro strap Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LCD; LEDs Illumination: yes Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV Phase-to-phase voltage range for phase sequence indication: 50...1000V AC Weight with battery: 350g Additional functions: torch RCD test: 30mA Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication Battery/ rechargeable battery: battery LR6 AA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 773 IP2X | CHAUVIN ARNOUX | Category: Indicators, Voltage & Continuity Testers Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65 IP rating: IP65 Body dimensions: 228x60x39mm Power supply: battery LR6 AA 1,5V x2 Standard equipment: IP2X test probes; Velcro strap Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1; NF C 18-510 Type of tester: electrical Resistance to: fall from 2m height Kind of display used: LCD; LEDs Illumination: yes Bandwidth for AC voltage measurements: 40...65Hz DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV Phase-to-phase voltage range for phase sequence indication: 50...1000V AC Weight with battery: 350g Additional functions: 17 step speed regulation; torch RCD test: 30mA Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing Continuity test: acoustic indication; optical indication Battery/ rechargeable battery: battery LR6 AA 1,5V x2 | товару немає в наявності | В кошику од. на суму грн. | ||
| C.A 850 | CHAUVIN ARNOUX | Category: Manometers and Pressure Meters Description: Manometer; -100÷100psi; LCD; Meas.accur: ±0,3%; 0÷50°C Type of meter: manometer Pressure measuring range: -100...100psi Kind of display used: LCD Measurement accuracy: ±0,3% Dimensions: 72x182x30mm Power supply: battery 6LR61 9V x1 Measuring instrument features: AUTO HOLD; automatic power-off; differential pressure measurements; logging of MAX, MIN Standard equipment: 2 connection tubes; soft case; user's manual Measurement: pressure Measuring unit: bar; cm H2O; ft H2O; in Hg; in H2O; kg/cm2; kPa; mm Hg; ozin2 Operating temperature: 0...50°C Measuring resolution: 0,01 psi Battery/ rechargeable battery: battery 6LR61 9V x1 Illumination: yes | товару немає в наявності | В кошику од. на суму грн. |