6630-05 MICROTEST


Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...5MHz
Standard equipment: mains cable; measuring probe FX-000C19
Supply voltage frequency: 50/60Hz
Type of meter: LCR meter
Display resolution: 800x480
Measurement time: < 0.003s
Output impedance: 25Ω; 100Ω
Measurement accuracy: ±0.05%
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Display parameters: 6 digits
Supply voltage: 100...240V
Operating temperature: 10...40°C
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість | Ціна |
---|---|
1+ | 372752.78 грн |
Відгуки про товар
Написати відгук
Технічний опис 6630-05 MICROTEST
Category: LCR Meter, Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480, Kind of display used: LCD TFT 7", Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance, Dimensions: 336x147x340mm, Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms, Measurement frequency: 10Hz...5MHz, Standard equipment: mains cable; measuring probe FX-000C19, Supply voltage frequency: 50/60Hz, Type of meter: LCR meter, Display resolution: 800x480, Measurement time: < 0.003s, Output impedance: 25Ω; 100Ω, Measurement accuracy: ±0.05%, Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host, Display parameters: 6 digits, Supply voltage: 100...240V, Operating temperature: 10...40°C, кількість в упаковці: 1 шт.
Інші пропозиції 6630-05 за ціною від 447303.33 грн до 447303.33 грн
Фото | Назва | Виробник | Інформація |
Доступність |
Ціна | ||||
---|---|---|---|---|---|---|---|---|---|
![]() +3 |
6630-05 | Виробник : MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Measurement frequency: 10Hz...5MHz Standard equipment: mains cable; measuring probe FX-000C19 Supply voltage frequency: 50/60Hz Type of meter: LCR meter Display resolution: 800x480 Measurement time: < 0.003s Output impedance: 25Ω; 100Ω Measurement accuracy: ±0.05% Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Display parameters: 6 digits Supply voltage: 100...240V Operating temperature: 10...40°C кількість в упаковці: 1 шт |
на замовлення 2 шт: термін постачання 14-21 дні (днів) |
|