BM155
  • BM155
  • BM155
  • BM155
  • BM155
  • BM155
  • BM155

BM155 BRYMEN


BM155.pdf Виробник: BRYMEN
Category: Meters and AC Clamp Probes
Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g
Type of meter: power
Kind of meter: pincers type
Measuring instrument features: automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; PEAK HOLD function for AC measurements; THD%-F immediately evaluates harmonic content in measured voltage and current signals
Kind of display used: LCD
Sampling: 1x/s (kW, kVA, kVAR); 4x/s
Max. diameter of measured cable: 45mm
AC current measuring range: 10mA...40A; 400A; 1kA
AC current measuring accuracy: ±(1% + 5 digits) (50/60Hz); ±(2,5% + 5 digits) (500Hz...3,1kHz); ±(2% + 5 digits) (45Hz...500Hz)
Bandwidth for AC current measurements: 40...500Hz
DC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(0,5% + 5 digits)
AC voltage measuring range: 100mV...600V
AC voltage measuring accuracy: ±(1,5% + 5 digits) (45Hz...500Hz); ±(2,5% + 5 digits) (500Hz...3,1kHz); ±(0,5% + 5 digits) (50/60Hz)
True effective value measurement: True RMS AC
Bandwidth for AC voltage measurements: 40...500Hz
Resistance measuring range: 100mΩ...999.9Ω
Resistance measuring accuracy: ±(1% + 6 digits)
Frequency measuring range: 10mHz...5Hz; 500Hz
Frequency measuring accuracy: ±(0,5% + 4 digits)
Temperature measuring range: -50...300°C
Temperature measurement accuracy: ±(2% + 3°C)
Active power measuring accuracy: ±(4,5% + 6 digits)
Reactive power measurement: 0...600kVAR
Reactive power measuring accuracy: ±(4,5% + 6 digits)
Apparent power measurement: 0...600kVA
Apparent power measuring accuracy: ±(3,5% + 6 digits)
Harmonic content measurement: 0...99,99%
Harmonic content measuring accuracy: ±(1% + 6 digits) (for fundamental harmonic); ±(2% + 6 digits) (for 4...51 harmonic); ±(5% + 6 digits) (for 2 and 3 harmonic)
Continuity test: acoustic indication; 10Ω...300Ω
Pollution degree: 2
Dimensions: 224x78x40mm
Weight with battery: 224g
Power supply: battery LR03 AAA 1,5V x2
Measurement: AC current; active power; AC voltage; apparent power; DC voltage; frequency; power factor; reactive power; resistance; temperature
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: case; drop-like K-type temperature probe; test leads
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Illumination: yes
на замовлення 2 шт:

термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+10496.4 грн
Відгуки про товар
Написати відгук

Технічний опис BM155 BRYMEN

Category: Meters and AC Clamp Probes, Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g, Type of meter: power, Kind of meter: pincers type, Measuring instrument features: automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; PEAK HOLD function for AC measurements; THD%-F immediately evaluates harmonic content in measured voltage and current signals, Kind of display used: LCD, Sampling: 1x/s (kW, kVA, kVAR); 4x/s, Max. diameter of measured cable: 45mm, AC current measuring range: 10mA...40A; 400A; 1kA, AC current measuring accuracy: ±(1% + 5 digits) (50/60Hz); ±(2,5% + 5 digits) (500Hz...3,1kHz); ±(2% + 5 digits) (45Hz...500Hz), Bandwidth for AC current measurements: 40...500Hz, DC voltage measuring range: 100mV...600V, DC voltage measuring accuracy: ±(0,5% + 5 digits), AC voltage measuring range: 100mV...600V, AC voltage measuring accuracy: ±(1,5% + 5 digits) (45Hz...500Hz); ±(2,5% + 5 digits) (500Hz...3,1kHz); ±(0,5% + 5 digits) (50/60Hz), True effective value measurement: True RMS AC, Bandwidth for AC voltage measurements: 40...500Hz, Resistance measuring range: 100mΩ...999.9Ω, Resistance measuring accuracy: ±(1% + 6 digits), Frequency measuring range: 10mHz...5Hz; 500Hz, Frequency measuring accuracy: ±(0,5% + 4 digits), Temperature measuring range: -50...300°C, Temperature measurement accuracy: ±(2% + 3°C), Active power measuring accuracy: ±(4,5% + 6 digits), Reactive power measurement: 0...600kVAR, Reactive power measuring accuracy: ±(4,5% + 6 digits), Apparent power measurement: 0...600kVA, Apparent power measuring accuracy: ±(3,5% + 6 digits), Harmonic content measurement: 0...99,99%, Harmonic content measuring accuracy: ±(1% + 6 digits) (for fundamental harmonic); ±(2% + 6 digits) (for 4...51 harmonic); ±(5% + 6 digits) (for 2 and 3 harmonic), Continuity test: acoustic indication; 10Ω...300Ω, Pollution degree: 2, Dimensions: 224x78x40mm, Weight with battery: 224g, Power supply: battery LR03 AAA 1,5V x2, Measurement: AC current; active power; AC voltage; apparent power; DC voltage; frequency; power factor; reactive power; resistance; temperature, Conform to the norm: CAT III 600V; EN 61010, Standard equipment: case; drop-like K-type temperature probe; test leads, Battery/ rechargeable battery: battery LR03 AAA 1,5V x2, Illumination: yes.