C.A 6113

C.A 6113 CHAUVIN ARNOUX


pVersion=0046&contRep=ZT&docId=005056AB752F1ED7AFA926321C780A15&compId=CA-6116N_DS.PDF?ci_sign=446a475b390dbf6a5965b47dbc7c13974b0253e4 Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD 5,7"; 320x240; IP53; Illumin: yes
Type of meter: appliance meter
Kind of display used: LCD 5,7"
Display resolution: 320x240
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Earthing resistance measuring accuracy: ±(2% + 2 digit)
Continuity test: acoustic indication; optical indication
RCD test: AC, A and F-type RCDs; general purpose
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
Measurement: AC current (with current clamps); AC voltage; continuity; DC voltage; earthing resistance; frequency; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Test voltage: 50V; 100V; 250V; 500V; 1kV
IP rating: IP53
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Power supply: rechargeable battery Ni-MH x1
Measuring instrument features: long operating time up to 24 hours; programmable alarm thresholds; test leads resistance compensation
Body dimensions: 280x190x128mm
Weight with battery: 2.2kg
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes
Optional equipment: CA-C177; CA-C177A; CA-MN77
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
Illumination: yes
Loop impedance measuring accuracy: ±(5% + 2 digit)
кількість в упаковці: 1 шт
товару немає в наявності

В кошику  од. на суму  грн.
Відгуки про товар
Написати відгук

Технічний опис C.A 6113 CHAUVIN ARNOUX

Category: Multimeters for Electrical Installations, Description: Meter: appliance meter; LCD 5,7"; 320x240; IP53; Illumin: yes, Type of meter: appliance meter, Kind of display used: LCD 5,7", Display resolution: 320x240, Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ, Earthing resistance measuring accuracy: ±(2% + 2 digit), Continuity test: acoustic indication; optical indication, RCD test: AC, A and F-type RCDs; general purpose, Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω, Measurement: AC current (with current clamps); AC voltage; continuity; DC voltage; earthing resistance; frequency; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop, Insulation resistance measuring ranges: 0.01MΩ...2GΩ, Test voltage: 50V; 100V; 250V; 500V; 1kV, IP rating: IP53, Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1, Power supply: rechargeable battery Ni-MH x1, Measuring instrument features: long operating time up to 24 hours; programmable alarm thresholds; test leads resistance compensation, Body dimensions: 280x190x128mm, Weight with battery: 2.2kg, Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes, Optional equipment: CA-C177; CA-C177A; CA-MN77, Battery/ rechargeable battery: rechargeable battery Ni-MH x1, Illumination: yes, Loop impedance measuring accuracy: ±(5% + 2 digit), кількість в упаковці: 1 шт.

Інші пропозиції C.A 6113

Фото Назва Виробник Інформація Доступність
Ціна
C.A 6113 C.A 6113 Виробник : CHAUVIN ARNOUX pVersion=0046&contRep=ZT&docId=005056AB752F1ED7AFA926321C780A15&compId=CA-6116N_DS.PDF?ci_sign=446a475b390dbf6a5965b47dbc7c13974b0253e4 Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD 5,7"; 320x240; IP53; Illumin: yes
Type of meter: appliance meter
Kind of display used: LCD 5,7"
Display resolution: 320x240
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Earthing resistance measuring accuracy: ±(2% + 2 digit)
Continuity test: acoustic indication; optical indication
RCD test: AC, A and F-type RCDs; general purpose
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
Measurement: AC current (with current clamps); AC voltage; continuity; DC voltage; earthing resistance; frequency; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Test voltage: 50V; 100V; 250V; 500V; 1kV
IP rating: IP53
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Power supply: rechargeable battery Ni-MH x1
Measuring instrument features: long operating time up to 24 hours; programmable alarm thresholds; test leads resistance compensation
Body dimensions: 280x190x128mm
Weight with battery: 2.2kg
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes
Optional equipment: CA-C177; CA-C177A; CA-MN77
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
Illumination: yes
Loop impedance measuring accuracy: ±(5% + 2 digit)
товару немає в наявності