RTC1K-202 | ROHDE & SCHWARZ | RTC1K-202 Digital Oscilloscopes |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC1K-202M | ROHDE & SCHWARZ | RTC1K-202M Digital Oscilloscopes |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC1K-302 | ROHDE & SCHWARZ | RTC1K-302 Digital Oscilloscopes |
товару немає в наявності |
В кошику од. на суму грн. | |||
![]() +1 |
RTC1K-302M | ROHDE & SCHWARZ |
![]() Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000 Band: 300MHz Max. input voltage: 150V Interface: Ethernet; USB Number of channels: 2 Display resolution: 640x480 Input impedance: 1MΩ/14pF Dimensions: 285x175x140mm Standard equipment: mains cable; oscilloscope probe (1 per channel) Additional functions: function generator; voltmeter; with built-in component test function Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT Sampling: 1Gsps Type of oscilloscope: mixed signal Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal Input coupling: AC, DC, GND Vertical resolution: 8bit Trigger modes: automatic; normal; single Trigger coupling: AC; DC; highpass; lowpass Manufacturer series: RTC1000 Rise time: ≤1.15ns Input sensitivity: 1mV/div...10V/div Time base: 1n...100s/div Supply voltage 400Hz: 100...120V AC Memory record length: 1Mpts Kind of display used: colour; LCD 6,5" Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
RTC1K-302M REFURBISHED | ROHDE & SCHWARZ |
![]() tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: RTC1002 Oszilloskop mit MSO/RTC-B223 Bandbreiten- & Signalformgenerator-Upgrade, passiver Tastkopf, Netzkabel, Adapter mit BNC, Handbuch Berechnete Anstiegszeit: 1.15ns hazardous: false rohsPhthalatesCompliant: TBA Abtastrate: 2GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.g Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: RTC1000 Series Bandbreite: 300MHz productTraceability: No Oszilloskopkanäle: 2 Analog, 8 Digital Oszilloskopanzeige: VGA-LCD-Farbanzeige mit Touchscreen SVHC: To Be Advised |
на замовлення 2 шт: термін постачання 21-31 дні (днів) |
|
||
![]() +1 |
RTC1K-52 | ROHDE & SCHWARZ |
![]() Description: Oscilloscope: digital; Ch: 2; 50MHz; 1Gsps; 1Mpts; colour,LCD 6,5" Type of oscilloscope: digital Number of channels: 2 Band: 50MHz Sampling: 1Gsps Memory record length: 1Mpts Kind of display used: colour; LCD 6,5" Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal Time base: 1n...100s/div Input coupling: AC, DC, GND Interface: Ethernet; USB Rise time: ≤7ns Input impedance: 1MΩ/14pF Input sensitivity: 1mV/div...10V/div Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT Standard equipment: mains cable; oscilloscope probe (1 per channel) Dimensions: 285x175x140mm Supply voltage: 100...240V AC Display resolution: 640x480 Additional functions: function generator; voltmeter; with built-in component test function Vertical resolution: 8bit Trigger modes: automatic; normal; single Trigger coupling: AC; DC; highpass; lowpass Max. input voltage: 150V Manufacturer series: RTC1000 Producer guarantee (months): 36 Supply voltage 400Hz: 100...120V AC кількість в упаковці: 1 шт |
на замовлення 1 шт: термін постачання 14-21 дні (днів) |
|
||
RTC1K-52M | ROHDE & SCHWARZ | RTC1K-52M Digital Oscilloscopes |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC1K-72 | ROHDE & SCHWARZ | RTC1K-72 Digital Oscilloscopes |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC1K-72M | ROHDE & SCHWARZ | RTC1K-72M Digital Oscilloscopes |
товару немає в наявності |
В кошику од. на суму грн. | |||
![]() |
RTC1K-COM2 | ROHDE & SCHWARZ |
Description: ROHDE & SCHWARZ - RTC1K-COM2 - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: DSO RTC1002, RTC-B223 300MHz, MSO-Option RTC-B1, Anwendungsbundle RTC-PK1, RTC-K1/K2/K3/B6 Berechnete Anstiegszeit: 1.15ns hazardous: false rohsPhthalatesCompliant: YES Abtastrate: 2GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.g Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: RTC1000 Series Bandbreite: 300MHz productTraceability: No Oszilloskopkanäle: 2 Analog, 8 Digital Oszilloskopanzeige: VGA LCD, farbig SVHC: To Be Advised |
на замовлення 5 шт: термін постачання 21-31 дні (днів) |
|
||
![]() +1 |
RTC1K-COM2 | ROHDE & SCHWARZ |
![]() Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000 Dimensions: 285x175x140mm Supply voltage: 100...240V AC Interface: Ethernet; USB Number of channels: 2 Display resolution: 640x480 Input impedance: 1MΩ/14pF Standard equipment: mains cable; oscilloscope probe (1 per channel); RTC-B1; RTC-B6; RTC-K1; RTC-K2; RTC-K3 Additional functions: function generator; voltmeter; with built-in component test function Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT; protocols analyse: I2C, SPI, UART/RS232/RS422/RS485, CAN/LIN Sampling: 1Gsps Type of oscilloscope: mixed signal Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal Input coupling: AC, DC, GND Vertical resolution: 8bit Trigger modes: automatic; normal; single Trigger coupling: AC; DC; highpass; lowpass Max. input voltage: 150V Manufacturer series: RTC1000 Band: 300MHz Rise time: ≤1.15ns Input sensitivity: 1mV/div...10V/div Time base: 1n...100s/div Supply voltage 400Hz: 100...120V AC Memory record length: 1Mpts Kind of display used: colour; LCD 6,5" кількість в упаковці: 1 шт |
на замовлення 2 шт: термін постачання 14-21 дні (днів) |
|
||
![]() |
RTC-B1 | ROHDE & SCHWARZ |
![]() tariffCode: 90309000 Art des Zubehörs: Mischsignal-Upgrade productTraceability: No rohsCompliant: NA euEccn: NLR hazardous: false rohsPhthalatesCompliant: NA Zur Verwendung mit: Digitaloszilloskope der Produktreihe RTC1000 von R&S usEccn: EAR99 Produktpalette: RTC1000 Series SVHC: To Be Advised |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
||
![]() |
RTC-B1 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: MSO option; Features: mixed signal option Type of test accessories: MSO option Test accessories features: mixed signal option Related items: RTC1000 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
RTC-B220 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Expansion option Type of test accessories: expansion option Test accessories features: bandwidth upgrade from 50MHz to 70MHz Related items: RTC1000 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-B221 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Expansion option Type of test accessories: expansion option Test accessories features: bandwidth upgrade from 50MHz to 100MHz Related items: RTC1000 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-B222 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Expansion option Type of test accessories: expansion option Test accessories features: bandwidth upgrade from 50MHz to 200MHz Related items: RTC1000 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-B223 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Expansion option Type of test accessories: expansion option Test accessories features: bandwidth upgrade from 50MHz to 300MHz Related items: RTC1000 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | |||
![]() |
RTC-BNDL | ROHDE & SCHWARZ |
![]() tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: DSO RTC1002, RTC-B223 300MHz, MSO-Option RTC-B1, Anwendungsbundle RTC-PK1, RTC-K1/K2/K3/B6 Berechnete Anstiegszeit: 1.15ns hazardous: false rohsPhthalatesCompliant: YES Abtastrate: 2GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.g Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: RTC1000 Series Bandbreite: 300MHz productTraceability: No Oszilloskopkanäle: 2 Analog, 8 Digital Oszilloskopanzeige: VGA LCD, farbig SVHC: To Be Advised |
на замовлення 2 шт: термін постачання 21-31 дні (днів) |
|
||
![]() +4 |
RTC-BNDL | ROHDE & SCHWARZ |
![]() Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000 Type of oscilloscope: mixed signal Number of channels: 2 Band: 300MHz Sampling: 1Gsps Memory record length: 1Mpts Kind of display used: colour; LCD 6,5" Trigger modes: automatic; normal; single Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal Time base: 1n...100s/div Max. input voltage: 150V Vertical resolution: 8bit Input coupling: AC, DC, GND Trigger coupling: AC; DC; highpass; lowpass Interface: Ethernet; USB Manufacturer series: RTC1000 Rise time: ≤1.15ns Input impedance: 1MΩ/14pF Input sensitivity: 1mV/div...10V/div Additional functions: function generator; voltmeter; with built-in component test function Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT; protocols analyse: I2C, SPI, UART/RS232/RS422/RS485, CAN/LIN Standard equipment: RTC-B6; RTC-K1; RTC-K2; RTC-K3 Dimensions: 285x175x140mm Supply voltage: 100...240V AC Supply voltage 400Hz: 100...120V AC Display resolution: 640x480 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
RTC-K1 | ROHDE & SCHWARZ | RTC-K1 Accessories for Oscilloscopes - Others |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-K2 | ROHDE & SCHWARZ | RTC-K2 Accessories for Oscilloscopes - Others |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-K2. | ROHDE & SCHWARZ |
![]() tariffCode: 90309000 euEccn: NLR hazardous: false usEccn: EAR99 |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-K3 | ROHDE & SCHWARZ | RTC-K3 Accessories for Oscilloscopes - Others |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-K6 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Expansion option; Features: arbitrary waveform generator Type of test accessories: expansion option Test accessories features: arbitrary waveform generator Related items: RTC1000 кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | |||
RTC-PK1 | ROHDE & SCHWARZ | RTC-PK1 Accessories for Oscilloscopes - Others |
товару немає в наявності |
В кошику од. на суму грн. | |||
![]() +1 |
RTC-Z3 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Cover Type of test accessories: cover Related items: RTC1000 кількість в упаковці: 1 шт |
на замовлення 1 шт: термін постачання 14-21 дні (днів) |
|
||
RTH-K19 | ROHDE & SCHWARZ |
Category: Accessories for Oscilloscopes - Others Description: Expansion option; Features: advanced triggering function Type of test accessories: expansion option Related items: RTH Scope RIder Test accessories features: advanced triggering function |
товару немає в наявності |
В кошику од. на суму грн. | |||
![]() |
RTH-K2 | ROHDE & SCHWARZ |
![]() Medium: - Software-Ausgabe: - Software-Sprache: Mehrere Sprachen Software: Serielle Triggerung & Decodierung, UART/RS-232/RS-422/RS-485 Zur Verwendung mit: Oszilloskope der Baureihe Scope Rider RTH von Rohde & Schwarz Unterstützte Betriebssysteme: - Lizenztyp: - Produktpalette: Scope Rider RTH SVHC: No SVHC (20-Jun-2016) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
||
![]() |
RTH-K201 | ROHDE & SCHWARZ |
![]() Medium: - Software-Ausgabe: - Software-Sprache: Mehrere Sprachen Software: Fernbedienung über Web-Interface Zur Verwendung mit: Oszilloskope der Baureihe Scope Rider RTH von Rohde & Schwarz Unterstützte Betriebssysteme: - Lizenztyp: - Produktpalette: Scope Rider RTH SVHC: No SVHC (20-Jun-2016) |
на замовлення 5 шт: термін постачання 21-31 дні (днів) |
|
||
![]() |
RTH-K9 | ROHDE & SCHWARZ |
![]() Medium: - Software-Ausgabe: - Software-Sprache: Mehrere Sprachen Software: Software für serielle Triggerung & Dekodierung, CAN-FD Zur Verwendung mit: R&S Scope Rider RTH Series Handheld Digital Oscilloscopes Unterstützte Betriebssysteme: - Lizenztyp: - Produktpalette: Scope Rider RTH SVHC: No SVHC (16-Jan-2020) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
||
![]() |
RTH-PK1 | ROHDE & SCHWARZ |
![]() Medium: - Software-Ausgabe: - Software-Sprache: Mehrere Sprachen Software: Anwendungs-Bundle Zur Verwendung mit: R&S Scope Rider RTH Series Handheld Digital Oscilloscopes Unterstützte Betriebssysteme: - Lizenztyp: - Produktpalette: Scope Rider RTH SVHC: No SVHC (16-Jan-2020) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
||
![]() |
RTH1002 | ROHDE & SCHWARZ |
Description: ROHDE & SCHWARZ - RTH1002 - Oszilloskop, Handgerät, tragbar, digital, Scope Rider RTH Series, 2 Kanäle, 60 MHz, 5 GSPS, 2Mpts tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch Berechnete Anstiegszeit: 5.8ns hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: YES Abtastrate: 5GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.a Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: Scope Rider RTH Series Bandbreite: 60MHz productTraceability: No Oszilloskopkanäle: 2 Kanäle Oszilloskopanzeige: TFT-LCD-Farbanzeige SVHC: No SVHC (20-Jun-2016) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
||
![]() +1 |
RTH1002 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2 Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 60MHz Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1002 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2 Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 60MHz Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1002MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2 Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 60MHz Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
RTH1002MSO | ROHDE & SCHWARZ |
![]() tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: MSO-Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch Berechnete Anstiegszeit: 5.8ns hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: YES Abtastrate: 5GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.a Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: Scope Rider RTH Series Bandbreite: 250MHz productTraceability: No Oszilloskopkanäle: 2+8 Kanäle Oszilloskopanzeige: TFT-LCD-Farbanzeige SVHC: No SVHC (20-Jun-2016) |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1002MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2 Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 60MHz Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1004 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51 Type of oscilloscope: handheld oscilloscope Band: 60MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
RTH1004 | ROHDE & SCHWARZ |
![]() tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: Oszilloskop, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch Berechnete Anstiegszeit: 5.8ns hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: YES Abtastrate: 5GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.a Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: Scope Rider RTH Series Bandbreite: 60MHz productTraceability: No Oszilloskopkanäle: 4 Kanäle Oszilloskopanzeige: TFT-LCD-Farbanzeige SVHC: No SVHC (20-Jun-2016) |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1004 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51 Type of oscilloscope: handheld oscilloscope Band: 60MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1004MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51 Type of oscilloscope: handheld oscilloscope Band: 60MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1004MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51 Type of oscilloscope: handheld oscilloscope Band: 60MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤5.8ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
RTH1012 | ROHDE & SCHWARZ |
Description: ROHDE & SCHWARZ - RTH1012 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 2 Kanäle, 100 MHz, 5 GSPS, 2Mpts, 3.5 ns tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch Berechnete Anstiegszeit: 3.5ns hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: YES Abtastrate: 5GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.a Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: Scope Rider RTH Series Bandbreite: 100MHz productTraceability: No Oszilloskopkanäle: 2 Kanäle Oszilloskopanzeige: TFT-LCD-Farbanzeige SVHC: No SVHC (20-Jun-2016) |
на замовлення 2 шт: термін постачання 21-31 дні (днів) |
|
||
![]() +1 |
RTH1012 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 100MHz Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1012 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 100MHz Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1012MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 100MHz Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1012MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 100MHz Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1014 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 100MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
RTH1014 | ROHDE & SCHWARZ |
![]() tariffCode: 90302000 rohsCompliant: YES Lieferumfang des Kits: Oszilloskop, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch Berechnete Anstiegszeit: 3.5ns hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: YES Abtastrate: 5GSPS Aufzeichnungslänge (Speichertiefe): 2Mpts usEccn: 3A992.a Netzsteckertyp: - Herstellergewährleistung: 3 Jahre euEccn: NLR Produktpalette: Scope Rider RTH Bandbreite: 100MHz productTraceability: No Oszilloskopkanäle: 4 Kanäle Oszilloskopanzeige: TFT-LCD-Farbanzeige SVHC: No SVHC (20-Jun-2016) |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
||
![]() +1 |
RTH1014 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 100MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1014MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 100MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1014MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 100MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤3.5ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1022 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 200MHz Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1022 | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 200MHz Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1022MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 200MHz Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1022MSO | ROHDE & SCHWARZ |
![]() ![]() Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7" Body dimensions: 201x293x74mm Interface: Ethernet; LAN; USB Number of channels: 2 Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Display resolution: 800x480 Input impedance: 1MΩ/12pF Standard equipment: oscilloscope probe (1 per channel); power supply Additional functions: multimeter Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Continuity test: acoustic indication; <10Ω Sampling: 2,5Gsps; 5Gsps interleaved Temperature measuring range: -200...850°C Type of oscilloscope: handheld oscilloscope Trigger: falling-edge; glitch; impulse width; rising-edge Input coupling: AC, DC Vertical resolution: 9bit Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Trigger coupling: AC; DC Max. input voltage: 300V Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors) Band: 200MHz Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Time base: 1n...500s/div Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ DC voltage measuring range: 1V; 10V; 100V; 1kV AC voltage measuring range: 1V; 10V; 100V; 1kV Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Diode test: 3V Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: dedicated mobile app Memory record length: 500kpts Connectors for the country: Europe; Great Britain; USA Touchpad: yes Frequency measuring accuracy: ±0.005% Capacitance measuring accuracy: ±(1%+ 0.05% range) DC voltage measuring accuracy: ±(0.05% + 0.03% range) AC voltage measuring accuracy: ±(0.02% + 0.05% range) Resistance measuring accuracy: ±(0.08%+0.03% range) Temperature measurement accuracy: ±(0.13% + 1°C) Kind of display used: colour; LCD TFT 7" Power supply: rechargeable battery Li-Ion x1 IP rating: IP51 Supply voltage: 100...240V AC кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1024 | ROHDE & SCHWARZ |
![]() Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 200MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
RTH1024 | ROHDE & SCHWARZ |
![]() Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 200MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +2 |
RTH1024MSO | ROHDE & SCHWARZ |
![]() Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4 Type of oscilloscope: handheld oscilloscope Band: 200MHz Vertical resolution: 9bit Kind of display used: colour; LCD TFT 7" Number of channels: 4 Sampling: 1,25Gsps; 5Gsps interleaved Memory record length: 500kpts Time base: 1n...500s/div Max. input voltage: 300V Display resolution: 800x480 Input coupling: AC, DC Trigger modes: automatic; normal; single Trigger source: CH1; CH2 Rise time: ≤1.75ns Input sensitivity: 2mV/div...100V/div Interface: Ethernet; LAN; USB Input impedance: 1MΩ/12pF Additional functions: voltmeter Power supply: rechargeable battery Li-Ion x1 Body dimensions: 201x293x74mm Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode Standard equipment: oscilloscope probe (1 per channel); power supply Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Supply voltage: 100...240V AC Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010 Trigger: falling-edge; glitch; impulse width; rising-edge Trigger coupling: AC; DC Storage temperature: -20...50°C Manufacturer series: RTH Scope Rider IP rating: IP51 Touchpad: yes |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
RTH1024MSO | ROHDE & SCHWARZ |
![]() tariffCode: 90302000 Abtastrate: 5GSPS productTraceability: No rohsCompliant: YES euEccn: NLR Netzsteckertyp: -888 hazardous: true hazardCode: 3481 rohsPhthalatesCompliant: YES Berechnete Anstiegszeit: 1.75ns usEccn: 3A992.a Bandbreite: 200MHz Produktpalette: Scope Rider RTH Series |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
|
RTC1K-202 |
Виробник: ROHDE & SCHWARZ
RTC1K-202 Digital Oscilloscopes
RTC1K-202 Digital Oscilloscopes
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-202M |
Виробник: ROHDE & SCHWARZ
RTC1K-202M Digital Oscilloscopes
RTC1K-202M Digital Oscilloscopes
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-302 |
Виробник: ROHDE & SCHWARZ
RTC1K-302 Digital Oscilloscopes
RTC1K-302 Digital Oscilloscopes
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-302M |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Digital Oscilloscopes
Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000
Band: 300MHz
Max. input voltage: 150V
Interface: Ethernet; USB
Number of channels: 2
Display resolution: 640x480
Input impedance: 1MΩ/14pF
Dimensions: 285x175x140mm
Standard equipment: mains cable; oscilloscope probe (1 per channel)
Additional functions: function generator; voltmeter; with built-in component test function
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT
Sampling: 1Gsps
Type of oscilloscope: mixed signal
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Input coupling: AC, DC, GND
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Trigger coupling: AC; DC; highpass; lowpass
Manufacturer series: RTC1000
Rise time: ≤1.15ns
Input sensitivity: 1mV/div...10V/div
Time base: 1n...100s/div
Supply voltage 400Hz: 100...120V AC
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Digital Oscilloscopes
Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000
Band: 300MHz
Max. input voltage: 150V
Interface: Ethernet; USB
Number of channels: 2
Display resolution: 640x480
Input impedance: 1MΩ/14pF
Dimensions: 285x175x140mm
Standard equipment: mains cable; oscilloscope probe (1 per channel)
Additional functions: function generator; voltmeter; with built-in component test function
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT
Sampling: 1Gsps
Type of oscilloscope: mixed signal
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Input coupling: AC, DC, GND
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Trigger coupling: AC; DC; highpass; lowpass
Manufacturer series: RTC1000
Rise time: ≤1.15ns
Input sensitivity: 1mV/div...10V/div
Time base: 1n...100s/div
Supply voltage 400Hz: 100...120V AC
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-302M REFURBISHED |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTC1K-302M REFURBISHED - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: RTC1002 Oszilloskop mit MSO/RTC-B223 Bandbreiten- & Signalformgenerator-Upgrade, passiver Tastkopf, Netzkabel, Adapter mit BNC, Handbuch
Berechnete Anstiegszeit: 1.15ns
hazardous: false
rohsPhthalatesCompliant: TBA
Abtastrate: 2GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.g
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: RTC1000 Series
Bandbreite: 300MHz
productTraceability: No
Oszilloskopkanäle: 2 Analog, 8 Digital
Oszilloskopanzeige: VGA-LCD-Farbanzeige mit Touchscreen
SVHC: To Be Advised
Description: ROHDE & SCHWARZ - RTC1K-302M REFURBISHED - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: RTC1002 Oszilloskop mit MSO/RTC-B223 Bandbreiten- & Signalformgenerator-Upgrade, passiver Tastkopf, Netzkabel, Adapter mit BNC, Handbuch
Berechnete Anstiegszeit: 1.15ns
hazardous: false
rohsPhthalatesCompliant: TBA
Abtastrate: 2GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.g
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: RTC1000 Series
Bandbreite: 300MHz
productTraceability: No
Oszilloskopkanäle: 2 Analog, 8 Digital
Oszilloskopanzeige: VGA-LCD-Farbanzeige mit Touchscreen
SVHC: To Be Advised
на замовлення 2 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 140380.82 грн |
RTC1K-52 |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Digital Oscilloscopes
Description: Oscilloscope: digital; Ch: 2; 50MHz; 1Gsps; 1Mpts; colour,LCD 6,5"
Type of oscilloscope: digital
Number of channels: 2
Band: 50MHz
Sampling: 1Gsps
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Time base: 1n...100s/div
Input coupling: AC, DC, GND
Interface: Ethernet; USB
Rise time: ≤7ns
Input impedance: 1MΩ/14pF
Input sensitivity: 1mV/div...10V/div
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT
Standard equipment: mains cable; oscilloscope probe (1 per channel)
Dimensions: 285x175x140mm
Supply voltage: 100...240V AC
Display resolution: 640x480
Additional functions: function generator; voltmeter; with built-in component test function
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Trigger coupling: AC; DC; highpass; lowpass
Max. input voltage: 150V
Manufacturer series: RTC1000
Producer guarantee (months): 36
Supply voltage 400Hz: 100...120V AC
кількість в упаковці: 1 шт
Category: Digital Oscilloscopes
Description: Oscilloscope: digital; Ch: 2; 50MHz; 1Gsps; 1Mpts; colour,LCD 6,5"
Type of oscilloscope: digital
Number of channels: 2
Band: 50MHz
Sampling: 1Gsps
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Time base: 1n...100s/div
Input coupling: AC, DC, GND
Interface: Ethernet; USB
Rise time: ≤7ns
Input impedance: 1MΩ/14pF
Input sensitivity: 1mV/div...10V/div
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT
Standard equipment: mains cable; oscilloscope probe (1 per channel)
Dimensions: 285x175x140mm
Supply voltage: 100...240V AC
Display resolution: 640x480
Additional functions: function generator; voltmeter; with built-in component test function
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Trigger coupling: AC; DC; highpass; lowpass
Max. input voltage: 150V
Manufacturer series: RTC1000
Producer guarantee (months): 36
Supply voltage 400Hz: 100...120V AC
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 95552.06 грн |
RTC1K-52M |
Виробник: ROHDE & SCHWARZ
RTC1K-52M Digital Oscilloscopes
RTC1K-52M Digital Oscilloscopes
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-72 |
Виробник: ROHDE & SCHWARZ
RTC1K-72 Digital Oscilloscopes
RTC1K-72 Digital Oscilloscopes
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-72M |
Виробник: ROHDE & SCHWARZ
RTC1K-72M Digital Oscilloscopes
RTC1K-72M Digital Oscilloscopes
товару немає в наявності
В кошику
од. на суму грн.
RTC1K-COM2 |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTC1K-COM2 - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: DSO RTC1002, RTC-B223 300MHz, MSO-Option RTC-B1, Anwendungsbundle RTC-PK1, RTC-K1/K2/K3/B6
Berechnete Anstiegszeit: 1.15ns
hazardous: false
rohsPhthalatesCompliant: YES
Abtastrate: 2GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.g
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: RTC1000 Series
Bandbreite: 300MHz
productTraceability: No
Oszilloskopkanäle: 2 Analog, 8 Digital
Oszilloskopanzeige: VGA LCD, farbig
SVHC: To Be Advised
Description: ROHDE & SCHWARZ - RTC1K-COM2 - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: DSO RTC1002, RTC-B223 300MHz, MSO-Option RTC-B1, Anwendungsbundle RTC-PK1, RTC-K1/K2/K3/B6
Berechnete Anstiegszeit: 1.15ns
hazardous: false
rohsPhthalatesCompliant: YES
Abtastrate: 2GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.g
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: RTC1000 Series
Bandbreite: 300MHz
productTraceability: No
Oszilloskopkanäle: 2 Analog, 8 Digital
Oszilloskopanzeige: VGA LCD, farbig
SVHC: To Be Advised
на замовлення 5 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 155978.69 грн |
RTC1K-COM2 |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Digital Oscilloscopes
Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000
Dimensions: 285x175x140mm
Supply voltage: 100...240V AC
Interface: Ethernet; USB
Number of channels: 2
Display resolution: 640x480
Input impedance: 1MΩ/14pF
Standard equipment: mains cable; oscilloscope probe (1 per channel); RTC-B1; RTC-B6; RTC-K1; RTC-K2; RTC-K3
Additional functions: function generator; voltmeter; with built-in component test function
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT; protocols analyse: I2C, SPI, UART/RS232/RS422/RS485, CAN/LIN
Sampling: 1Gsps
Type of oscilloscope: mixed signal
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Input coupling: AC, DC, GND
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Trigger coupling: AC; DC; highpass; lowpass
Max. input voltage: 150V
Manufacturer series: RTC1000
Band: 300MHz
Rise time: ≤1.15ns
Input sensitivity: 1mV/div...10V/div
Time base: 1n...100s/div
Supply voltage 400Hz: 100...120V AC
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
кількість в упаковці: 1 шт
Category: Digital Oscilloscopes
Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000
Dimensions: 285x175x140mm
Supply voltage: 100...240V AC
Interface: Ethernet; USB
Number of channels: 2
Display resolution: 640x480
Input impedance: 1MΩ/14pF
Standard equipment: mains cable; oscilloscope probe (1 per channel); RTC-B1; RTC-B6; RTC-K1; RTC-K2; RTC-K3
Additional functions: function generator; voltmeter; with built-in component test function
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT; protocols analyse: I2C, SPI, UART/RS232/RS422/RS485, CAN/LIN
Sampling: 1Gsps
Type of oscilloscope: mixed signal
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Input coupling: AC, DC, GND
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Trigger coupling: AC; DC; highpass; lowpass
Max. input voltage: 150V
Manufacturer series: RTC1000
Band: 300MHz
Rise time: ≤1.15ns
Input sensitivity: 1mV/div...10V/div
Time base: 1n...100s/div
Supply voltage 400Hz: 100...120V AC
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 224575.64 грн |
RTC-B1 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTC-B1 - Upgrade, Testlizenzschlüssel, Mischsignal-Upgrade
tariffCode: 90309000
Art des Zubehörs: Mischsignal-Upgrade
productTraceability: No
rohsCompliant: NA
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: NA
Zur Verwendung mit: Digitaloszilloskope der Produktreihe RTC1000 von R&S
usEccn: EAR99
Produktpalette: RTC1000 Series
SVHC: To Be Advised
Description: ROHDE & SCHWARZ - RTC-B1 - Upgrade, Testlizenzschlüssel, Mischsignal-Upgrade
tariffCode: 90309000
Art des Zubehörs: Mischsignal-Upgrade
productTraceability: No
rohsCompliant: NA
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: NA
Zur Verwendung mit: Digitaloszilloskope der Produktreihe RTC1000 von R&S
usEccn: EAR99
Produktpalette: RTC1000 Series
SVHC: To Be Advised
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 41264.20 грн |
RTC-B1 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: MSO option; Features: mixed signal option
Type of test accessories: MSO option
Test accessories features: mixed signal option
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: MSO option; Features: mixed signal option
Type of test accessories: MSO option
Test accessories features: mixed signal option
Related items: RTC1000
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-B220 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 70MHz
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 70MHz
Related items: RTC1000
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-B221 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 100MHz
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 100MHz
Related items: RTC1000
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-B222 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 200MHz
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 200MHz
Related items: RTC1000
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-B223 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 300MHz
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: Expansion option
Type of test accessories: expansion option
Test accessories features: bandwidth upgrade from 50MHz to 300MHz
Related items: RTC1000
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-BNDL |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTC-BNDL - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: DSO RTC1002, RTC-B223 300MHz, MSO-Option RTC-B1, Anwendungsbundle RTC-PK1, RTC-K1/K2/K3/B6
Berechnete Anstiegszeit: 1.15ns
hazardous: false
rohsPhthalatesCompliant: YES
Abtastrate: 2GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.g
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: RTC1000 Series
Bandbreite: 300MHz
productTraceability: No
Oszilloskopkanäle: 2 Analog, 8 Digital
Oszilloskopanzeige: VGA LCD, farbig
SVHC: To Be Advised
Description: ROHDE & SCHWARZ - RTC-BNDL - Oszilloskop, MSO / MDO, RTC1000 Series, 2 Analog, 8 Digital, 300 MHz, 2 GSPS, 2Mpts, 1.15 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: DSO RTC1002, RTC-B223 300MHz, MSO-Option RTC-B1, Anwendungsbundle RTC-PK1, RTC-K1/K2/K3/B6
Berechnete Anstiegszeit: 1.15ns
hazardous: false
rohsPhthalatesCompliant: YES
Abtastrate: 2GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.g
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: RTC1000 Series
Bandbreite: 300MHz
productTraceability: No
Oszilloskopkanäle: 2 Analog, 8 Digital
Oszilloskopanzeige: VGA LCD, farbig
SVHC: To Be Advised
на замовлення 2 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 143599.43 грн |
RTC-BNDL |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Digital Oscilloscopes
Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000
Type of oscilloscope: mixed signal
Number of channels: 2
Band: 300MHz
Sampling: 1Gsps
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
Trigger modes: automatic; normal; single
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Time base: 1n...100s/div
Max. input voltage: 150V
Vertical resolution: 8bit
Input coupling: AC, DC, GND
Trigger coupling: AC; DC; highpass; lowpass
Interface: Ethernet; USB
Manufacturer series: RTC1000
Rise time: ≤1.15ns
Input impedance: 1MΩ/14pF
Input sensitivity: 1mV/div...10V/div
Additional functions: function generator; voltmeter; with built-in component test function
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT; protocols analyse: I2C, SPI, UART/RS232/RS422/RS485, CAN/LIN
Standard equipment: RTC-B6; RTC-K1; RTC-K2; RTC-K3
Dimensions: 285x175x140mm
Supply voltage: 100...240V AC
Supply voltage 400Hz: 100...120V AC
Display resolution: 640x480
кількість в упаковці: 1 шт
Category: Digital Oscilloscopes
Description: Oscilloscope: mixed signal; Ch: 2; 300MHz; 1Gsps; 1Mpts; RTC1000
Type of oscilloscope: mixed signal
Number of channels: 2
Band: 300MHz
Sampling: 1Gsps
Memory record length: 1Mpts
Kind of display used: colour; LCD 6,5"
Trigger modes: automatic; normal; single
Trigger: falling-edge; impulse width; logic; rising-edge; serial protocol; video signal
Time base: 1n...100s/div
Max. input voltage: 150V
Vertical resolution: 8bit
Input coupling: AC, DC, GND
Trigger coupling: AC; DC; highpass; lowpass
Interface: Ethernet; USB
Manufacturer series: RTC1000
Rise time: ≤1.15ns
Input impedance: 1MΩ/14pF
Input sensitivity: 1mV/div...10V/div
Additional functions: function generator; voltmeter; with built-in component test function
Measuring instrument features: EF function - electrical field detecion; mask testing; mathematical functions: addition, subtraction, division, multiplication and FFT; protocols analyse: I2C, SPI, UART/RS232/RS422/RS485, CAN/LIN
Standard equipment: RTC-B6; RTC-K1; RTC-K2; RTC-K3
Dimensions: 285x175x140mm
Supply voltage: 100...240V AC
Supply voltage 400Hz: 100...120V AC
Display resolution: 640x480
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-K1 |
Виробник: ROHDE & SCHWARZ
RTC-K1 Accessories for Oscilloscopes - Others
RTC-K1 Accessories for Oscilloscopes - Others
товару немає в наявності
В кошику
од. на суму грн.
RTC-K2 |
Виробник: ROHDE & SCHWARZ
RTC-K2 Accessories for Oscilloscopes - Others
RTC-K2 Accessories for Oscilloscopes - Others
товару немає в наявності
В кошику
од. на суму грн.
RTC-K2. |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTC-K2. - TRIGGERUNG UART/RS232/RS422/RS485 SERIAL
tariffCode: 90309000
euEccn: NLR
hazardous: false
usEccn: EAR99
Description: ROHDE & SCHWARZ - RTC-K2. - TRIGGERUNG UART/RS232/RS422/RS485 SERIAL
tariffCode: 90309000
euEccn: NLR
hazardous: false
usEccn: EAR99
товару немає в наявності
В кошику
од. на суму грн.
RTC-K3 |
Виробник: ROHDE & SCHWARZ
RTC-K3 Accessories for Oscilloscopes - Others
RTC-K3 Accessories for Oscilloscopes - Others
товару немає в наявності
В кошику
од. на суму грн.
RTC-K6 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Expansion option; Features: arbitrary waveform generator
Type of test accessories: expansion option
Test accessories features: arbitrary waveform generator
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: Expansion option; Features: arbitrary waveform generator
Type of test accessories: expansion option
Test accessories features: arbitrary waveform generator
Related items: RTC1000
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTC-PK1 |
Виробник: ROHDE & SCHWARZ
RTC-PK1 Accessories for Oscilloscopes - Others
RTC-PK1 Accessories for Oscilloscopes - Others
товару немає в наявності
В кошику
од. на суму грн.
RTC-Z3 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Cover
Type of test accessories: cover
Related items: RTC1000
кількість в упаковці: 1 шт
Category: Accessories for Oscilloscopes - Others
Description: Cover
Type of test accessories: cover
Related items: RTC1000
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 20559.48 грн |
RTH-K19 |
Виробник: ROHDE & SCHWARZ
Category: Accessories for Oscilloscopes - Others
Description: Expansion option; Features: advanced triggering function
Type of test accessories: expansion option
Related items: RTH Scope RIder
Test accessories features: advanced triggering function
Category: Accessories for Oscilloscopes - Others
Description: Expansion option; Features: advanced triggering function
Type of test accessories: expansion option
Related items: RTH Scope RIder
Test accessories features: advanced triggering function
товару немає в наявності
В кошику
од. на суму грн.
RTH-K2 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH-K2 - Test-Software, Serielle Triggerung & Decodierung, UART/RS-232/RS-422/RS-485, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Serielle Triggerung & Decodierung, UART/RS-232/RS-422/RS-485
Zur Verwendung mit: Oszilloskope der Baureihe Scope Rider RTH von Rohde & Schwarz
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH-K2 - Test-Software, Serielle Triggerung & Decodierung, UART/RS-232/RS-422/RS-485, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Serielle Triggerung & Decodierung, UART/RS-232/RS-422/RS-485
Zur Verwendung mit: Oszilloskope der Baureihe Scope Rider RTH von Rohde & Schwarz
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (20-Jun-2016)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 64646.98 грн |
RTH-K201 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH-K201 - Test-Software, Fernbedienung über Web-Interface, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Fernbedienung über Web-Interface
Zur Verwendung mit: Oszilloskope der Baureihe Scope Rider RTH von Rohde & Schwarz
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH-K201 - Test-Software, Fernbedienung über Web-Interface, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Fernbedienung über Web-Interface
Zur Verwendung mit: Oszilloskope der Baureihe Scope Rider RTH von Rohde & Schwarz
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (20-Jun-2016)
на замовлення 5 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 30535.51 грн |
RTH-K9 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH-K9 - Test-Software, Software für serielle Triggerung & Dekodierung, CAN-FD, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Software für serielle Triggerung & Dekodierung, CAN-FD
Zur Verwendung mit: R&S Scope Rider RTH Series Handheld Digital Oscilloscopes
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (16-Jan-2020)
Description: ROHDE & SCHWARZ - RTH-K9 - Test-Software, Software für serielle Triggerung & Dekodierung, CAN-FD, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Software für serielle Triggerung & Dekodierung, CAN-FD
Zur Verwendung mit: R&S Scope Rider RTH Series Handheld Digital Oscilloscopes
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (16-Jan-2020)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 82610.94 грн |
RTH-PK1 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH-PK1 - Test-Software, Anwendungs-Bundle, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Anwendungs-Bundle
Zur Verwendung mit: R&S Scope Rider RTH Series Handheld Digital Oscilloscopes
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (16-Jan-2020)
Description: ROHDE & SCHWARZ - RTH-PK1 - Test-Software, Anwendungs-Bundle, Mehrere Sprachen
Medium: -
Software-Ausgabe: -
Software-Sprache: Mehrere Sprachen
Software: Anwendungs-Bundle
Zur Verwendung mit: R&S Scope Rider RTH Series Handheld Digital Oscilloscopes
Unterstützte Betriebssysteme: -
Lizenztyp: -
Produktpalette: Scope Rider RTH
SVHC: No SVHC (16-Jan-2020)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 303704.55 грн |
RTH1002 |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH1002 - Oszilloskop, Handgerät, tragbar, digital, Scope Rider RTH Series, 2 Kanäle, 60 MHz, 5 GSPS, 2Mpts
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 5.8ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 60MHz
productTraceability: No
Oszilloskopkanäle: 2 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH1002 - Oszilloskop, Handgerät, tragbar, digital, Scope Rider RTH Series, 2 Kanäle, 60 MHz, 5 GSPS, 2Mpts
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 5.8ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 60MHz
productTraceability: No
Oszilloskopkanäle: 2 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 314433.24 грн |
RTH1002 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
товару немає в наявності
В кошику
од. на суму грн.
RTH1002 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1002MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
товару немає в наявності
В кошику
од. на суму грн.
RTH1002MSO |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH1002MSO - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 2+8 Kanäle, 250 MHz, 5 GSPS, 2Mpts, 5.8 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: MSO-Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 5.8ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 250MHz
productTraceability: No
Oszilloskopkanäle: 2+8 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH1002MSO - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 2+8 Kanäle, 250 MHz, 5 GSPS, 2Mpts, 5.8 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: MSO-Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 5.8ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 250MHz
productTraceability: No
Oszilloskopkanäle: 2+8 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
товару немає в наявності
В кошику
од. на суму грн.
RTH1002MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 60MHz; 9bit; colour,LCD TFT 7"; Ch: 2
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 60MHz
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1004 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
товару немає в наявності
В кошику
од. на суму грн.
RTH1004 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH1004 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 4 Kanäle, 60 MHz, 5 GSPS, 2Mpts, 5.8 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 5.8ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 60MHz
productTraceability: No
Oszilloskopkanäle: 4 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH1004 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 4 Kanäle, 60 MHz, 5 GSPS, 2Mpts, 5.8 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 5.8ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 60MHz
productTraceability: No
Oszilloskopkanäle: 4 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
товару немає в наявності
В кошику
од. на суму грн.
RTH1004 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1004MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
товару немає в наявності
В кошику
од. на суму грн.
RTH1004MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 60MHz; 9bit; colour,LCD TFT 7"; Ch: 4; IP51
Type of oscilloscope: handheld oscilloscope
Band: 60MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤5.8ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1012 |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH1012 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 2 Kanäle, 100 MHz, 5 GSPS, 2Mpts, 3.5 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 3.5ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 100MHz
productTraceability: No
Oszilloskopkanäle: 2 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH1012 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 2 Kanäle, 100 MHz, 5 GSPS, 2Mpts, 3.5 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, DMM, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 3.5ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH Series
Bandbreite: 100MHz
productTraceability: No
Oszilloskopkanäle: 2 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
на замовлення 2 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 390359.38 грн |
RTH1012 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
товару немає в наявності
В кошику
од. на суму грн.
RTH1012 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1012MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
товару немає в наявності
В кошику
од. на суму грн.
RTH1012MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 100MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 100MHz
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1014 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
товару немає в наявності
В кошику
од. на суму грн.
RTH1014 |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH1014 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH, 4 Kanäle, 100 MHz, 5 GSPS, 2Mpts, 3.5 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 3.5ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH
Bandbreite: 100MHz
productTraceability: No
Oszilloskopkanäle: 4 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
Description: ROHDE & SCHWARZ - RTH1014 - Oszilloskop, Handgerät, tragbar, Scope Rider RTH, 4 Kanäle, 100 MHz, 5 GSPS, 2Mpts, 3.5 ns
tariffCode: 90302000
rohsCompliant: YES
Lieferumfang des Kits: Oszilloskop, Spannungstastkopf, Messleitung, Lithium-Ionen-Akkupack, Netzteil, Handbuch
Berechnete Anstiegszeit: 3.5ns
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Abtastrate: 5GSPS
Aufzeichnungslänge (Speichertiefe): 2Mpts
usEccn: 3A992.a
Netzsteckertyp: -
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Produktpalette: Scope Rider RTH
Bandbreite: 100MHz
productTraceability: No
Oszilloskopkanäle: 4 Kanäle
Oszilloskopanzeige: TFT-LCD-Farbanzeige
SVHC: No SVHC (20-Jun-2016)
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 299578.12 грн |
RTH1014 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1014MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
товару немає в наявності
В кошику
од. на суму грн.
RTH1014MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 100MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 100MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤3.5ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1022 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
товару немає в наявності
В кошику
од. на суму грн.
RTH1022 |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1022MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
товару немає в наявності
В кошику
од. на суму грн.
RTH1022MSO |
![]() ![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; Band: 200MHz; 9bit; colour,LCD TFT 7"
Body dimensions: 201x293x74mm
Interface: Ethernet; LAN; USB
Number of channels: 2
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Display resolution: 800x480
Input impedance: 1MΩ/12pF
Standard equipment: oscilloscope probe (1 per channel); power supply
Additional functions: multimeter
Measuring instrument features: automatic measurement of many parameters; banana socket x2; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Continuity test: acoustic indication; <10Ω
Sampling: 2,5Gsps; 5Gsps interleaved
Temperature measuring range: -200...850°C
Type of oscilloscope: handheld oscilloscope
Trigger: falling-edge; glitch; impulse width; rising-edge
Input coupling: AC, DC
Vertical resolution: 9bit
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Trigger coupling: AC; DC
Max. input voltage: 300V
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
Measurement: AC current (with current clamps); AC voltage; capacitance; continuity; DC voltage; frequency; resistance; temperature (with PT100 or PT500 platinum sensors)
Band: 200MHz
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Time base: 1n...500s/div
Resistance measuring range: 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 1V; 10V; 100V; 1kV
Frequency measuring range: 1kHz; 10kHz; 100kHz; 1MHz
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 3V
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: dedicated mobile app
Memory record length: 500kpts
Connectors for the country: Europe; Great Britain; USA
Touchpad: yes
Frequency measuring accuracy: ±0.005%
Capacitance measuring accuracy: ±(1%+ 0.05% range)
DC voltage measuring accuracy: ±(0.05% + 0.03% range)
AC voltage measuring accuracy: ±(0.02% + 0.05% range)
Resistance measuring accuracy: ±(0.08%+0.03% range)
Temperature measurement accuracy: ±(0.13% + 1°C)
Kind of display used: colour; LCD TFT 7"
Power supply: rechargeable battery Li-Ion x1
IP rating: IP51
Supply voltage: 100...240V AC
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1024 |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 200MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 200MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
товару немає в наявності
В кошику
од. на суму грн.
RTH1024 |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 200MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 200MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
RTH1024MSO |
![]() |
Виробник: ROHDE & SCHWARZ
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 200MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 9bit; colour,LCD TFT 7"; Ch: 4
Type of oscilloscope: handheld oscilloscope
Band: 200MHz
Vertical resolution: 9bit
Kind of display used: colour; LCD TFT 7"
Number of channels: 4
Sampling: 1,25Gsps; 5Gsps interleaved
Memory record length: 500kpts
Time base: 1n...500s/div
Max. input voltage: 300V
Display resolution: 800x480
Input coupling: AC, DC
Trigger modes: automatic; normal; single
Trigger source: CH1; CH2
Rise time: ≤1.75ns
Input sensitivity: 2mV/div...100V/div
Interface: Ethernet; LAN; USB
Input impedance: 1MΩ/12pF
Additional functions: voltmeter
Power supply: rechargeable battery Li-Ion x1
Body dimensions: 201x293x74mm
Measuring instrument features: automatic measurement of many parameters; datalogging; insulated inputs; mask testing; mathematical functions: addition, subtraction, multiplication, square, absolute value, inverse and FFT; measurements by means of cursors; more trigger types with RTH-K19 option; multilanguage menu; option of memory card connection microSDHC (4GB-32GB); Y-T, X-Y, zoom operation mode
Standard equipment: oscilloscope probe (1 per channel); power supply
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Supply voltage: 100...240V AC
Conform to the norm: CAT II 1000V; CAT III 600V; CAT III 1000V; CAT IV 600V; EN 61010
Trigger: falling-edge; glitch; impulse width; rising-edge
Trigger coupling: AC; DC
Storage temperature: -20...50°C
Manufacturer series: RTH Scope Rider
IP rating: IP51
Touchpad: yes
товару немає в наявності
В кошику
од. на суму грн.
RTH1024MSO |
![]() |
Виробник: ROHDE & SCHWARZ
Description: ROHDE & SCHWARZ - RTH1024MSO - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 4+8 Kanäle, 200 MHz, 5 GSPS, 2Mpts
tariffCode: 90302000
Abtastrate: 5GSPS
productTraceability: No
rohsCompliant: YES
euEccn: NLR
Netzsteckertyp: -888
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Berechnete Anstiegszeit: 1.75ns
usEccn: 3A992.a
Bandbreite: 200MHz
Produktpalette: Scope Rider RTH Series
Description: ROHDE & SCHWARZ - RTH1024MSO - Oszilloskop, Handgerät, tragbar, Scope Rider RTH Series, 4+8 Kanäle, 200 MHz, 5 GSPS, 2Mpts
tariffCode: 90302000
Abtastrate: 5GSPS
productTraceability: No
rohsCompliant: YES
euEccn: NLR
Netzsteckertyp: -888
hazardous: true
hazardCode: 3481
rohsPhthalatesCompliant: YES
Berechnete Anstiegszeit: 1.75ns
usEccn: 3A992.a
Bandbreite: 200MHz
Produktpalette: Scope Rider RTH Series
на замовлення 1 шт:
термін постачання 21-31 дні (днів)Кількість | Ціна |
---|---|
1+ | 504826.28 грн |