34450A KEYSIGHT TECHNOLOGIES

Description: KEYSIGHT TECHNOLOGIES - 34450A - Digitalmultimeter, Tischgerät, TRMS, automatische/manuelle Bereichswahl, 1kV, 10A, 5.5-stellig
tariffCode: 90318080
Messwert Wechselspannung, max.: 750V
Messwert Widerstand, max.: 0.1Gohm
Messwert Gleichspannung, max.: 1kV
Messwert Gleichstrom, max.: 10A
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: YES
usEccn: 3A992.a
Netzsteckertyp: EU, UK
Herstellergewährleistung: 3 Jahre
euEccn: NLR
Anzahl der Stellen: 5.5
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Diode, Frequenz, Widerstand, Temperatur
DMM-Konnektivität: USB
Produktpalette: Truevolt Series
productTraceability: No
Messwert Wechselstrom, max.: 10A
SVHC: No SVHC (17-Jan-2023)
на замовлення 22 шт:
термін постачання 21-31 дні (днів)
Кількість | Ціна |
---|---|
1+ | 93708.84 грн |
Відгуки про товар
Написати відгук
Технічний опис 34450A KEYSIGHT TECHNOLOGIES
Category: Benchtop digital multimeters, Description: Benchtop multimeter; OLED; 5,5 digit; True RMS AC; I AC: 10mA÷10A, Type of meter: benchtop multimeter, Kind of display used: OLED, Display parameters: 5,5 digit, True effective value measurement: True RMS AC, DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV, DC voltage measuring accuracy: ±(0.015% + 0.005% range), AC voltage measuring range: 100mV; 1V; 750V, DC current measuring range: 100µA; 1mA; 10mA; 100mA; 1A; 10A, DC current measuring accuracy: ±(0.05% + 0.015% range), AC current measuring range: 10mA...10A, AC current measuring accuracy: ±(0.5% + 0.1% range), Resistance measuring range: 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ, Resistance measuring accuracy: ±(0.05%+0.005% range), Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF, Capacitance measuring accuracy: ±(1%+ 0.5% range), Diode test: 0.5mA @1V, Continuity test: acoustic indication, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature, Interface: USB A, Connectors for the country: Europe, Supply voltage: 240V AC, Pollution degree: 2, Dimensions: 104x261x303mm, Standard equipment: mains cable; manufacturer's calibration certificate; test leads; USB cable; user's manual, Related items: 10833A; 10833B; 10833C; 10833D; 10833F; 10833G; 34138A; 34190A; 34191A; 34194A; 82350B; 82357B; E2308A, Information: Products are intended for professional and industrial use only, and are not suitable for consumer or household use., Frequency measuring accuracy: ±(0.02% + 0.003% range), Frequency measuring range: 20...300kHz, Temperature measuring range: -80...150°C, кількість в упаковці: 1 шт.
Інші пропозиції 34450A за ціною від 92218.98 грн до 92218.98 грн
Фото | Назва | Виробник | Інформація |
Доступність |
Ціна | ||||
---|---|---|---|---|---|---|---|---|---|
34450A | Виробник : Keysight |
![]() |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
|||||
![]() |
34450A | Виробник : KEYSIGHT |
![]() ![]() ![]() Description: Benchtop multimeter; OLED; 5,5 digit; True RMS AC; I AC: 10mA÷10A Type of meter: benchtop multimeter Kind of display used: OLED Display parameters: 5,5 digit True effective value measurement: True RMS AC DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.015% + 0.005% range) AC voltage measuring range: 100mV; 1V; 750V DC current measuring range: 100µA; 1mA; 10mA; 100mA; 1A; 10A DC current measuring accuracy: ±(0.05% + 0.015% range) AC current measuring range: 10mA...10A AC current measuring accuracy: ±(0.5% + 0.1% range) Resistance measuring range: 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Resistance measuring accuracy: ±(0.05%+0.005% range) Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Capacitance measuring accuracy: ±(1%+ 0.5% range) Diode test: 0.5mA @1V Continuity test: acoustic indication Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Interface: USB A Connectors for the country: Europe Supply voltage: 240V AC Pollution degree: 2 Dimensions: 104x261x303mm Standard equipment: mains cable; manufacturer's calibration certificate; test leads; USB cable; user's manual Related items: 10833A; 10833B; 10833C; 10833D; 10833F; 10833G; 34138A; 34190A; 34191A; 34194A; 82350B; 82357B; E2308A Information: Products are intended for professional and industrial use only, and are not suitable for consumer or household use. Frequency measuring accuracy: ±(0.02% + 0.003% range) Frequency measuring range: 20...300kHz Temperature measuring range: -80...150°C кількість в упаковці: 1 шт |
товару немає в наявності |
|||||
![]() |
34450A | Виробник : KEYSIGHT |
![]() ![]() ![]() Description: Benchtop multimeter; OLED; 5,5 digit; True RMS AC; I AC: 10mA÷10A Type of meter: benchtop multimeter Kind of display used: OLED Display parameters: 5,5 digit True effective value measurement: True RMS AC DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV DC voltage measuring accuracy: ±(0.015% + 0.005% range) AC voltage measuring range: 100mV; 1V; 750V DC current measuring range: 100µA; 1mA; 10mA; 100mA; 1A; 10A DC current measuring accuracy: ±(0.05% + 0.015% range) AC current measuring range: 10mA...10A AC current measuring accuracy: ±(0.5% + 0.1% range) Resistance measuring range: 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ Resistance measuring accuracy: ±(0.05%+0.005% range) Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF Capacitance measuring accuracy: ±(1%+ 0.5% range) Diode test: 0.5mA @1V Continuity test: acoustic indication Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Interface: USB A Connectors for the country: Europe Supply voltage: 240V AC Pollution degree: 2 Dimensions: 104x261x303mm Standard equipment: mains cable; manufacturer's calibration certificate; test leads; USB cable; user's manual Related items: 10833A; 10833B; 10833C; 10833D; 10833F; 10833G; 34138A; 34190A; 34191A; 34194A; 82350B; 82357B; E2308A Information: Products are intended for professional and industrial use only, and are not suitable for consumer or household use. Frequency measuring accuracy: ±(0.02% + 0.003% range) Frequency measuring range: 20...300kHz Temperature measuring range: -80...150°C |
товару немає в наявності |