Технічний опис CL490 Klein Tools

Category: Meters and AC/DC Clamp Probes, Description: Meter: multifunction; digital,AC/DC pincers type; Øcable: 41mm, Resistance to: fall from 2m height, AC current measuring range: 10mA...400A, Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 4mF, Test: circuit continuity; diodes, Battery/ rechargeable battery: battery AAA x2, Measuring instrument features: automatic or manual selection of measuring ranges; automatic power-off; contactless voltage measurement; for use with type-K thermocouple; HOLD function; low battery indicator; MIN/MAX function, Power supply: battery AA x2, DC voltage measuring accuracy: ±(0.8% + 3 digit) @(4V...400V); ±(1% + 3 digit) @600V; ±(1% + 8 digit) @400mV, Standard equipment: case; test leads; thermocouple; user's manual, Kind of meter: AC/DC pincers type; digital, DC current measuring accuracy: ±(2% + 9 digit) @(40A...400A), Pollution degree: 2, Kind of display used: LCD, Temperature measuring range: -40...1000°C, Continuity test: acoustic indication; .

Інші пропозиції CL490

Фото Назва Виробник Інформація Доступність Ціна без ПДВ
CL490 CL490 Klein Tools Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,AC/DC pincers type; Øcable: 41mm
Resistance to: fall from 2m height
AC current measuring range: 10mA...400A
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 4mF
Test: circuit continuity; diodes
Battery/ rechargeable battery: battery AAA x2
Measuring instrument features: automatic or manual selection of measuring ranges; automatic power-off; contactless voltage measurement; for use with type-K thermocouple; HOLD function; low battery indicator; MIN/MAX function
Power supply: battery AA x2
DC voltage measuring accuracy: ±(0.8% + 3 digit) @(4V...400V); ±(1% + 3 digit) @600V; ±(1% + 8 digit) @400mV
Standard equipment: case; test leads; thermocouple; user's manual
Kind of meter: AC/DC pincers type; digital
DC current measuring accuracy: ±(2% + 9 digit) @(40A...400A)
Pollution degree: 2
Kind of display used: LCD
Temperature measuring range: -40...1000°C
Continuity test: acoustic indication; <10Ω
True effective value measurement: True RMS
DC current measuring range: 10mA...400A
DC voltage measuring range: 400mV; 4V; 40V; 400V; 600V
AC current measuring accuracy: ±(2% + 9 digit)@(40A...400A)
Max. diameter of measured cable: 41mm
Weight with battery: 346g
Dimensions: 215x90x38mm
Frequency measuring range: 10Hz...60kHz
AC voltage measuring range: 400mV; 4V; 40V; 400V; 600V
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Conform to the norm: CAT III 600V; EN 61326-1
Illumination: yes
Resistance measuring accuracy: ±(1.2%+3 digit)@(4kΩ...4MΩ); ±(1.2%+5 digit)@(400Ω); ±(2%+5 digit)@(40MΩ)
AC voltage measuring accuracy: ±(1.2% + 5 digit) @(40V...400V); ±(1.5% + 5 digit) @4V; ±(1.5% + 5 digit) @600V; ±(1.8% + 5 digit) @400mV
Type of meter: multifunction
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; measurement (by K thermocouple); resistance
товару немає в наявності
В кошику  од. на суму  грн.
CL490
Виробник: Klein Tools
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,AC/DC pincers type; Øcable: 41mm
Resistance to: fall from 2m height
AC current measuring range: 10mA...400A
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 4mF
Test: circuit continuity; diodes
Battery/ rechargeable battery: battery AAA x2
Measuring instrument features: automatic or manual selection of measuring ranges; automatic power-off; contactless voltage measurement; for use with type-K thermocouple; HOLD function; low battery indicator; MIN/MAX function
Power supply: battery AA x2
DC voltage measuring accuracy: ±(0.8% + 3 digit) @(4V...400V); ±(1% + 3 digit) @600V; ±(1% + 8 digit) @400mV
Standard equipment: case; test leads; thermocouple; user's manual
Kind of meter: AC/DC pincers type; digital
DC current measuring accuracy: ±(2% + 9 digit) @(40A...400A)
Pollution degree: 2
Kind of display used: LCD
Temperature measuring range: -40...1000°C
Continuity test: acoustic indication; <10Ω
True effective value measurement: True RMS
DC current measuring range: 10mA...400A
DC voltage measuring range: 400mV; 4V; 40V; 400V; 600V
AC current measuring accuracy: ±(2% + 9 digit)@(40A...400A)
Max. diameter of measured cable: 41mm
Weight with battery: 346g
Dimensions: 215x90x38mm
Frequency measuring range: 10Hz...60kHz
AC voltage measuring range: 400mV; 4V; 40V; 400V; 600V
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Conform to the norm: CAT III 600V; EN 61326-1
Illumination: yes
Resistance measuring accuracy: ±(1.2%+3 digit)@(4kΩ...4MΩ); ±(1.2%+5 digit)@(400Ω); ±(2%+5 digit)@(40MΩ)
AC voltage measuring accuracy: ±(1.2% + 5 digit) @(40V...400V); ±(1.5% + 5 digit) @4V; ±(1.5% + 5 digit) @600V; ±(1.8% + 5 digit) @400mV
Type of meter: multifunction
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; measurement (by K thermocouple); resistance
товару немає в наявності