FLUKE-28IIEX






Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
True effective value measurement: True RMS
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Diode test: 1mA @2.8V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Weight with battery: 517g
Dimensions (W x H x D): 100x198x63.5mm
Illumination: yes
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
IP rating: IP67
Conductance measuring accuracy: ±(1% + 10digit)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість | Ціна |
---|---|
1+ | 142763.42 грн |
Відгуки про товар
Написати відгук
Технічний опис FLUKE-28IIEX FLUKE
Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s, Type of meter: digital multimeter, Kind of display used: LCD, Display parameters: (6000/19999), Bargraph: 33 segm. 40x/s, True effective value measurement: True RMS, DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, DC voltage measuring accuracy: ±(0.05% + 1 digit), AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, AC voltage measuring accuracy: ±(1% + 4 digit), DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A, DC current measuring accuracy: ±(0.2% + 2 digit), AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A, AC current measuring accuracy: ±(1% + 2 digit), Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ, Resistance measuring accuracy: ±(0.2%+1 digit), Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF, Capacitance measuring accuracy: ±(1%+ 2 digit), Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz, Frequency measuring accuracy: ±(0.005%+1 digit), Temperature measuring range: -200...1090°C, Temperature measurement accuracy: ±(1% + 10 digit), Diode test: 1mA @2.8V, Continuity test: acoustic indication, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Power supply: battery LR03 AAA 1,5V x3, Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case, Standard equipment: test leads, Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA, Duty cycle factor: 0...99.9%, Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%, Temperature measurement resolution: 0.1°C, Conductance measurement: 0.01...60nS, Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71, Weight with battery: 517g, Dimensions (W x H x D): 100x198x63.5mm, Illumination: yes, Battery/ rechargeable battery: battery LR03 AAA 1,5V x3, IP rating: IP67, Conductance measuring accuracy: ±(1% + 10digit).
Інші пропозиції FLUKE-28IIEX за ціною від 146735.51 грн до 146735.51 грн
Фото | Назва | Виробник | Інформація |
Доступність |
Ціна | ||||
---|---|---|---|---|---|---|---|---|---|
![]() |
FLUKE 28 II EX | Виробник : FLUKE |
![]() tariffCode: 90303100 Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV Messwert Widerstand, max.: 50Mohm Messwert Gleichstrom, max.: 10A rohsCompliant: Y-EX hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Schritte: 20000 Herstellergewährleistung: 3 Jahre euEccn: NLR Anzahl der Stellen: 4.5 DMM-Messverfahren: Echteffektivwert DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Diode, Frequenz, Widerstand, Temperatur Produktpalette: - productTraceability: No Messwert Wechselstrom, max.: 10A Bereichswahl: Automatisch, manuell SVHC: No SVHC (25-Jun-2020) |
на замовлення 28 шт: термін постачання 21-31 дні (днів) |
|
||||
FLUKE 28 II EX | Виробник : FLUKE | FLK-28-2-EX Portable digital multimeters |
товару немає в наявності |