FLUKE-568EX
Виробник: FLUKE
Category: Pirometers
Description: Infrared thermometer; LCD; -40÷800°C; Accur.(IR): ±1%,±1°C
Type of meter: infrared thermometer
Kind of display used: LCD
Non-contact temperature measuring range: -40...800°C
Non-contact temperature measuring accuracy: ±1%; ±1°C
Temperature measuring range measured by probe: -40...260°C
Temperature measuring accuracy (measurement with probe): ±1.1°C
Non-contact temperature measuring resolution: 0.1°C
Optical resolution: 50:1
Emissivity value: 0,1...1
Emissivity resolution: 10m
Response time: <0.5s
Measurement: non-contact temeprature (IR)
Measuring unit: °C; °F
Dimensions: 177x164x52mm
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: acoustic and optical signalling of set MIN/MAX threshold values; adjustable emissivity; contact or non-contact temperature measurement; HOLD function; laser sight; low battery indicator; MIN/MAX/MEAN/REL function; records data together with date and time markers
Standard equipment: case; K-type temperature probe; user's manual
Measurement memory: 99
Illumination: yes
Відгуки про товар
Написати відгук
Технічний опис FLUKE-568EX FLUKE
Category: Pirometers, Description: Infrared thermometer; LCD; -40÷800°C; Accur.(IR): ±1%,±1°C, Type of meter: infrared thermometer, Kind of display used: LCD, Non-contact temperature measuring range: -40...800°C, Non-contact temperature measuring accuracy: ±1%; ±1°C, Temperature measuring range measured by probe: -40...260°C, Temperature measuring accuracy (measurement with probe): ±1.1°C, Non-contact temperature measuring resolution: 0.1°C, Optical resolution: 50:1, Emissivity value: 0,1...1, Emissivity resolution: 10m, Response time: .
Інші пропозиції FLUKE-568EX
| Фото | Назва | Виробник | Інформація | Доступність | Ціна без ПДВ |
|---|---|---|---|---|---|
|
FLUKE 568EX | FLUKE |
Description: FLUKE - FLUKE 568EX - IR- / Infrarotthermometer, -40°C bis +800°C, 1 %, 0 °C, 50 °C tariffCode: 90258040 euEccn: NLR rohsCompliant: TBA Temperaturmessbereich: -40°C bis +800°C hazardous: false rohsPhthalatesCompliant: TBA isCanonical: Y Wellenlänge, max.: 670nm Betriebstemperatur, min.: 0°C SVHC: No SVHC (14-Jun-2023) Produktpalette: - productTraceability: No usEccn: EAR99 Betriebstemperatur, max.: 50°C Genauigkeit %: 1% |
на замовлення 1 шт: термін постачання 21-31 дні (днів) |
В кошику од. на суму грн. |
| FLUKE 568EX |
Виробник: FLUKE
Description: FLUKE - FLUKE 568EX - IR- / Infrarotthermometer, -40°C bis +800°C, 1 %, 0 °C, 50 °C
tariffCode: 90258040
euEccn: NLR
rohsCompliant: TBA
Temperaturmessbereich: -40°C bis +800°C
hazardous: false
rohsPhthalatesCompliant: TBA
isCanonical: Y
Wellenlänge, max.: 670nm
Betriebstemperatur, min.: 0°C
SVHC: No SVHC (14-Jun-2023)
Produktpalette: -
productTraceability: No
usEccn: EAR99
Betriebstemperatur, max.: 50°C
Genauigkeit %: 1%
Description: FLUKE - FLUKE 568EX - IR- / Infrarotthermometer, -40°C bis +800°C, 1 %, 0 °C, 50 °C
tariffCode: 90258040
euEccn: NLR
rohsCompliant: TBA
Temperaturmessbereich: -40°C bis +800°C
hazardous: false
rohsPhthalatesCompliant: TBA
isCanonical: Y
Wellenlänge, max.: 670nm
Betriebstemperatur, min.: 0°C
SVHC: No SVHC (14-Jun-2023)
Produktpalette: -
productTraceability: No
usEccn: EAR99
Betriebstemperatur, max.: 50°C
Genauigkeit %: 1%
на замовлення 1 шт:
термін постачання 21-31 дні (днів)