KE-FLB Kurth Electronic


KE-FLB-data.pdf KE-FLB-manual.pdf Виробник: Kurth Electronic
Category: LAN and Telephone Networks Testers
Description: Tester: wire fault localizer; LCD; Interface: RS232C; VDC: 0÷100V
Type of tester: wire fault localizer
Kind of display used: LCD
Detection: place of cable failure
Interface: RS232C
Measuring range: 0,1...20km
DC voltage measuring range: 0...100V
DC voltage measuring accuracy: ±(1% + 100mV)
AC voltage measuring range: 0...100V
Resistance measuring range: 1...5000Ω
Capacitance measuring range: 1nF...25µF
Capacitance measuring accuracy: ±(0.5%+ 1 digit)
Temperature measuring range: -20...60°C
Insulation resistance measuring accuracy: ±(1% + 1digit)
Short circuit loop resistance measuring range: 1Ω...10kΩ
Short circuit loop resistance measuring accuracy: ±(0.2% + 0.1Ω)
Power supply: rechargeable battery x1
Operating temperature: -10...50°C
Dimensions: 200x100x40mm
Application: telecommunication
Measuring instrument features: 7 test modes; operates with thermocouple types: PT1000
Standard equipment: case; connection cable; EFF 50 adapter; manufacturer's calibration certificate; power supply; shoulder strap; test leads; user's manual
Battery/ rechargeable battery: rechargeable battery x1
Software: included
Display resolution: 128x128
Insulation resistance measuring ranges: 10kΩ...100MΩ
AC voltage measuring accuracy: ±(1% + 100mV)
Resistance measuring accuracy: ±(0.2%+0.05Ω)
Temperature measurement accuracy: ±0.4°C
кількість в упаковці: 1 шт
товар відсутній

Відгуки про товар
Написати відгук

Технічний опис KE-FLB Kurth Electronic

Category: LAN and Telephone Networks Testers, Description: Tester: wire fault localizer; LCD; Interface: RS232C; VDC: 0÷100V, Type of tester: wire fault localizer, Kind of display used: LCD, Detection: place of cable failure, Interface: RS232C, Measuring range: 0,1...20km, DC voltage measuring range: 0...100V, DC voltage measuring accuracy: ±(1% + 100mV), AC voltage measuring range: 0...100V, Resistance measuring range: 1...5000Ω, Capacitance measuring range: 1nF...25µF, Capacitance measuring accuracy: ±(0.5%+ 1 digit), Temperature measuring range: -20...60°C, Insulation resistance measuring accuracy: ±(1% + 1digit), Short circuit loop resistance measuring range: 1Ω...10kΩ, Short circuit loop resistance measuring accuracy: ±(0.2% + 0.1Ω), Power supply: rechargeable battery x1, Operating temperature: -10...50°C, Dimensions: 200x100x40mm, Application: telecommunication, Measuring instrument features: 7 test modes; operates with thermocouple types: PT1000, Standard equipment: case; connection cable; EFF 50 adapter; manufacturer's calibration certificate; power supply; shoulder strap; test leads; user's manual, Battery/ rechargeable battery: rechargeable battery x1, Software: included, Display resolution: 128x128, Insulation resistance measuring ranges: 10kΩ...100MΩ, AC voltage measuring accuracy: ±(1% + 100mV), Resistance measuring accuracy: ±(0.2%+0.05Ω), Temperature measurement accuracy: ±0.4°C, кількість в упаковці: 1 шт.

Інші пропозиції KE-FLB

Фото Назва Виробник Інформація Доступність
Ціна без ПДВ
KE-FLB Виробник : Kurth Electronic KE-FLB-data.pdf KE-FLB-manual.pdf Category: LAN and Telephone Networks Testers
Description: Tester: wire fault localizer; LCD; Interface: RS232C; VDC: 0÷100V
Type of tester: wire fault localizer
Kind of display used: LCD
Detection: place of cable failure
Interface: RS232C
Measuring range: 0,1...20km
DC voltage measuring range: 0...100V
DC voltage measuring accuracy: ±(1% + 100mV)
AC voltage measuring range: 0...100V
Resistance measuring range: 1...5000Ω
Capacitance measuring range: 1nF...25µF
Capacitance measuring accuracy: ±(0.5%+ 1 digit)
Temperature measuring range: -20...60°C
Insulation resistance measuring accuracy: ±(1% + 1digit)
Short circuit loop resistance measuring range: 1Ω...10kΩ
Short circuit loop resistance measuring accuracy: ±(0.2% + 0.1Ω)
Power supply: rechargeable battery x1
Operating temperature: -10...50°C
Dimensions: 200x100x40mm
Application: telecommunication
Measuring instrument features: 7 test modes; operates with thermocouple types: PT1000
Standard equipment: case; connection cable; EFF 50 adapter; manufacturer's calibration certificate; power supply; shoulder strap; test leads; user's manual
Battery/ rechargeable battery: rechargeable battery x1
Software: included
Display resolution: 128x128
Insulation resistance measuring ranges: 10kΩ...100MΩ
AC voltage measuring accuracy: ±(1% + 100mV)
Resistance measuring accuracy: ±(0.2%+0.05Ω)
Temperature measurement accuracy: ±0.4°C