Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; (9999); Bargraph: 29segm; 19mm Battery/ rechargeable battery: battery LR14 1,5V x8 Power supply: battery LR14 1,5V x8 Standard equipment: crocodile clips; hard case; test leads Conform to the norm: CAT III 600V; EN 61010 Type of meter: insulation resistance Kind of display used: LCD Interface: USB Display height 1: 19mm AC voltage measuring range: 1...30V; 600V DC voltage measuring range: 1...30V; 600V Body dimensions: 202x155x94mm DC voltage measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(2% + 5 digit) Pollution degree: 2 Insulation resistance measuring accuracy: ±(3% + 5digit) Measurement memory: 18 Bargraph: 29 segm. Test voltage: 500V; 1kV; 1.5kV; 2.5kV Weight with battery: 2kg Measuring instrument features: 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement; automatic power-off; autoranging; low battery indicator Insulation resistance measuring ranges: 0.1MΩ...500kΩ; 2MΩ; 5MΩ; 10MΩ; 100MΩ; 5GΩ; 10GΩ; 20GΩ; 100GΩ Display parameters: (9999) Measurement: AC voltage; DC voltage; insulation resistance Continuity test: acoustic indication; <30Ω Protection: anti-overload OPP |
на замовлення 7 шт: термін постачання 14-30 дні (днів) |
|
||||
| UT512 | UNI-T |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 30÷750V; VDC: 30÷1000V Battery/ rechargeable battery: battery LR14 1,5V x8 Power supply: battery LR14 1,5V x8 Standard equipment: carrying strap; test leads; USB cable Conform to the norm: CAT IV 600V Type of meter: insulation resistance Kind of display used: LCD Interface: USB AC voltage measuring range: 30...750V DC voltage measuring range: 30...1000V Body dimensions: 238x166x90.5mm DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Insulation resistance measuring accuracy: ±(5% + 5digit) Test voltage: 250V; 500V; 1kV; 2.5kV Measuring instrument features: 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement; automatic power-off; autoranging; low battery indicator Insulation resistance measuring ranges: 100GΩ; 200GΩ; 400GΩ; 1TΩ Measurement: AC voltage; DC voltage; insulation resistance |
на замовлення 1 шт: термін постачання 14-30 дні (днів) |
|
| UT512 |
![]() |
Виробник: UNI-T
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (9999); Bargraph: 29segm; 19mm
Battery/ rechargeable battery: battery LR14 1,5V x8
Power supply: battery LR14 1,5V x8
Standard equipment: crocodile clips; hard case; test leads
Conform to the norm: CAT III 600V; EN 61010
Type of meter: insulation resistance
Kind of display used: LCD
Interface: USB
Display height 1: 19mm
AC voltage measuring range: 1...30V; 600V
DC voltage measuring range: 1...30V; 600V
Body dimensions: 202x155x94mm
DC voltage measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(2% + 5 digit)
Pollution degree: 2
Insulation resistance measuring accuracy: ±(3% + 5digit)
Measurement memory: 18
Bargraph: 29 segm.
Test voltage: 500V; 1kV; 1.5kV; 2.5kV
Weight with battery: 2kg
Measuring instrument features: 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement; automatic power-off; autoranging; low battery indicator
Insulation resistance measuring ranges: 0.1MΩ...500kΩ; 2MΩ; 5MΩ; 10MΩ; 100MΩ; 5GΩ; 10GΩ; 20GΩ; 100GΩ
Display parameters: (9999)
Measurement: AC voltage; DC voltage; insulation resistance
Continuity test: acoustic indication; <30Ω
Protection: anti-overload OPP
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (9999); Bargraph: 29segm; 19mm
Battery/ rechargeable battery: battery LR14 1,5V x8
Power supply: battery LR14 1,5V x8
Standard equipment: crocodile clips; hard case; test leads
Conform to the norm: CAT III 600V; EN 61010
Type of meter: insulation resistance
Kind of display used: LCD
Interface: USB
Display height 1: 19mm
AC voltage measuring range: 1...30V; 600V
DC voltage measuring range: 1...30V; 600V
Body dimensions: 202x155x94mm
DC voltage measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(2% + 5 digit)
Pollution degree: 2
Insulation resistance measuring accuracy: ±(3% + 5digit)
Measurement memory: 18
Bargraph: 29 segm.
Test voltage: 500V; 1kV; 1.5kV; 2.5kV
Weight with battery: 2kg
Measuring instrument features: 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement; automatic power-off; autoranging; low battery indicator
Insulation resistance measuring ranges: 0.1MΩ...500kΩ; 2MΩ; 5MΩ; 10MΩ; 100MΩ; 5GΩ; 10GΩ; 20GΩ; 100GΩ
Display parameters: (9999)
Measurement: AC voltage; DC voltage; insulation resistance
Continuity test: acoustic indication; <30Ω
Protection: anti-overload OPP
на замовлення 7 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна |
|---|---|
| 1+ | 12807.29 грн |
| 3+ | 11867.26 грн |
| UT512 |
![]() |
Виробник: UNI-T
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 30÷750V; VDC: 30÷1000V
Battery/ rechargeable battery: battery LR14 1,5V x8
Power supply: battery LR14 1,5V x8
Standard equipment: carrying strap; test leads; USB cable
Conform to the norm: CAT IV 600V
Type of meter: insulation resistance
Kind of display used: LCD
Interface: USB
AC voltage measuring range: 30...750V
DC voltage measuring range: 30...1000V
Body dimensions: 238x166x90.5mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Insulation resistance measuring accuracy: ±(5% + 5digit)
Test voltage: 250V; 500V; 1kV; 2.5kV
Measuring instrument features: 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement; automatic power-off; autoranging; low battery indicator
Insulation resistance measuring ranges: 100GΩ; 200GΩ; 400GΩ; 1TΩ
Measurement: AC voltage; DC voltage; insulation resistance
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 30÷750V; VDC: 30÷1000V
Battery/ rechargeable battery: battery LR14 1,5V x8
Power supply: battery LR14 1,5V x8
Standard equipment: carrying strap; test leads; USB cable
Conform to the norm: CAT IV 600V
Type of meter: insulation resistance
Kind of display used: LCD
Interface: USB
AC voltage measuring range: 30...750V
DC voltage measuring range: 30...1000V
Body dimensions: 238x166x90.5mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Insulation resistance measuring accuracy: ±(5% + 5digit)
Test voltage: 250V; 500V; 1kV; 2.5kV
Measuring instrument features: 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement; automatic power-off; autoranging; low battery indicator
Insulation resistance measuring ranges: 100GΩ; 200GΩ; 400GΩ; 1TΩ
Measurement: AC voltage; DC voltage; insulation resistance
на замовлення 1 шт:
термін постачання 14-30 дні (днів)
| Кількість | Ціна |
|---|---|
| 1+ | 20010.65 грн |