Фото | Назва | Виробник | Інформація |
Доступність |
Ціна |
||
---|---|---|---|---|---|---|---|
![]() +4 |
FLUKE-116 EUR | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Battery/ rechargeable battery: battery 6LR61 9V x1 Kind of display used: LCD Power supply: battery 6LR61 9V x1 Conform to the norm: CAT III 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: FLK-TL75 test leads Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Continuity test: acoustic indication; <20Ω Pollution degree: 2 Measuring instruments application: heating and air-conditioning technology Temperature measuring range: -40...400°C Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature Dimensions (W x H x D): 84x167x46mm AC current measuring range: 0.1...600µA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 0.1...600µA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.2mA @2.7V Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Temperature measurement accuracy: ±(0.1% + 2 digit) |
на замовлення 5 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-117 EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Kind of display used: LCD Power supply: battery 6LR61 9V x1 Conform to the norm: CAT III 600V; EN 61010 Related items: POM-5673B; POM-5900A/POM; POM-7519A Standard equipment: FLK-TL75 test leads Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Continuity test: acoustic indication; <20Ω Pollution degree: 2 Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 84x167x46mm AC current measuring range: 1mA...6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.2mA @2.7V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) |
на замовлення 78 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +4 |
FLUKE-175 EGFID | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Weight with battery: 420g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Continuity test: acoustic indication; <25Ω Manufacturer series: Fluke 170 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 89x190x45mm AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.15% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 |
на замовлення 34 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-177 EGFID | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Weight with battery: 420g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Continuity test: acoustic indication; <25Ω Manufacturer series: Fluke 170 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 89x190x45mm AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 |
на замовлення 129 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +4 |
FLUKE-179 EGFID | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Kind of display used: LCD Power supply: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Weight with battery: 420g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Continuity test: acoustic indication; <25Ω Temperature measuring range: -40...400°C Manufacturer series: Fluke 170 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Dimensions (W x H x D): 89x190x45mm AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) |
на замовлення 157 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +4 |
FLUKE-1577 | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 IP rating: IP40 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-C25 soft cover Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS AC Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance Dimensions (W x H x D): 100x203x50mm Test voltage: 500V; 1kV AC current measuring range: 10µA...60mA; 400mA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) AC current measuring accuracy: ±(2% + 2 digit) DC voltage measuring accuracy: ±(0.2% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Resistance measuring accuracy: ±(1.2%+2 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +1 |
2824477 | FLUKE |
Category: Accessories - Others Description: Battery container Type of test accessories: battery container Related items: FLK-289 |
на замовлення 26 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLK-3000FC/EDA2 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter Related items: POM-5677B; POM-5899A; POM-7519A Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910 Type of meter: digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x3 |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +9 |
FLUKE-179/EDA2/EUR | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Digital multimeter Related items: POM-5904A/POM; POM-6343; POM-7519A Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip Type of meter: digital multimeter Battery/ rechargeable battery: battery 6LR61 9V x1 |
на замовлення 7 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +8 |
FLUKE-179/MAG2 KIT | FLUKE |
![]() ![]() Description: Digital multimeter Related items: POM-5904A/POM; POM-6343; POM-7519A Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4 Type of meter: digital multimeter Battery/ rechargeable battery: battery 6F22 9V x1 |
на замовлення 12 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE-T110 | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Body dimensions: 255x78x35mm Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 12...690V AC Measurement: AC voltage; DC voltage Bandwidth for AC voltage measurements: 0...400Hz DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP64 |
на замовлення 54 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE T110/VDE | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP64 Body dimensions: 255x78x35mm Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Type of tester: electrical Additional functions: illumination lamp Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measurement: AC voltage; DC voltage Bandwidth for AC voltage measurements: 0...400Hz DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) |
на замовлення 5 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +2 |
FLUKE-T90 | FLUKE |
![]() Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator Body dimensions: 245x64x28mm Conform to the norm: CAT II 690V; CAT III 600V; EN 61010 Additional functions: illumination lamp Weight with battery: 180g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 12...690V AC Measurement: AC voltage; DC voltage Bandwidth for AC voltage measurements: 0...400Hz DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP54 |
на замовлення 34 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE-T130 | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Body dimensions: 255x78x35mm Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 6...690V AC Measurement: AC voltage; DC voltage Bandwidth for AC voltage measurements: 0...400Hz DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: 3,5 digit DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Kind of display used: LCD; LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP64 |
на замовлення 48 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE T130/VDE | FLUKE |
![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Kind of display used: LCD; LEDs Measurement: AC voltage; DC voltage DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Body dimensions: 255x78x35mm Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 100...690V AC Bandwidth for AC voltage measurements: 0...400Hz AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Display parameters: 3,5 digit DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) IP rating: IP64 |
на замовлення 10 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE-T150 | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Body dimensions: 255x78x35mm Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 6...690V AC Measurement: AC voltage; DC voltage; resistance Bandwidth for AC voltage measurements: 0...400Hz Resistance measuring range: 1...1999Ω DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: 3,5 digit DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) Kind of display used: LCD; LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP64 |
на замовлення 84 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE T150/VDE | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Body dimensions: 255x78x35mm Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measurement: AC voltage; DC voltage; resistance Bandwidth for AC voltage measurements: 0...400Hz Resistance measuring range: 1...1999Ω DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: 3,5 digit DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) Kind of display used: LCD; LEDs Power supply: battery LR03 AAA 1,5V x2 IP rating: IP64 |
на замовлення 44 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-787B | FLUKE |
![]() ![]() Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Dimensions: 203x100x50mm Related items: POM-5900A/POM; POM-6173A; POM-7519A Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71 Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Type of meter: multimeter calibrator Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Continuity test: acoustic indication; <100Ω AC current measuring range: 0.001mA...1A Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ DC current measuring range: 1µA...30mA; 1A DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Diode test: 0.3mA @600mV Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Software: Fluke Connect (FLK-IR3000FC) Frequency measuring accuracy: ±(0.005%+1 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 2 digit) Resistance measuring accuracy: ±(0.2%+1 digit) |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +2 |
FLUKE-789/E | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Interface: IrDA Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Dimensions: 203x100x50mm Related items: POM-5900A/POM; POM-6173A; POM-7519A Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Type of meter: multimeter calibrator Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Continuity test: acoustic indication; <100Ω Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance AC current measuring range: 0.001mA...1A Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ DC current measuring range: 1µA...30mA; 1A DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Diode test: 0.3mA @600mV Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Software: Fluke Connect (FLK-IR3000FC) Frequency measuring accuracy: ±(0.005%+1 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1.2% + 4 digit) Resistance measuring accuracy: ±(0.2%+1 digit) |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +13 |
FLUKE-88-5/A KIT | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD DC voltage measuring range: 0...1kV AC voltage measuring range: 0...1kV DC current measuring range: 0...10A AC current measuring range: 0...10A True effective value measurement: True RMS AC Resistance measuring range: 0...50MΩ Capacitance measuring range: 0...10000µF Frequency measuring range: 0...200kHz Continuity test: acoustic indication Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 86x186x32mm Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds Battery/ rechargeable battery: battery 6F22 9V x1 Bargraph: yes Diode test: 3V Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Temperature measuring range: -200...1090°C |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +2 |
FLUKE-279FC/IFLEX | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter with infrared camera; Bluetooth Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Refresh rate: 8Hz Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads Type of meter: digital multimeter with infrared camera Continuity test: acoustic indication; <25Ω Non-contact temperature measuring range: -10...200°C Emissivity value: 0,95 (fixed) Focusing: focus free Camera resolution: 80x60 Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance Dimensions (W x H x D): 93.9x215.9x57.1mm Thermal sensitivity (NETD): ≤0.2°C AC current measuring range: 100mA...999.9A; 2.5kA Resistance measuring range: 600Ω...50MΩ DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 99.99...999.9Hz Capacitance measuring range: 1000nF...9999µF Diode test: 2V Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1 Connectors for the country: Europe; Great Britain |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLK-3000FC | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV Kind of display used: LCD Power supply: battery LR6 AA 1,5V x3 IP rating: IP54 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function Type of meter: digital multimeter Weight with battery: 340g Continuity test: acoustic indication True effective value measurement: True RMS Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 93x207x48mm AC current measuring range: 60mA; 400mA Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 60mA; 400mA DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF Diode test: 2V Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Software: compatible Android; Fluke Connect Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.5%+1 digit) |
на замовлення 4 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-1587 T | FLUKE |
![]() ![]() Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Type of meter: digital multimeter Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Kind of display used: LCD Display parameters: (6000) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring range: 10µA...60mA; 400mA DC current measuring accuracy: ±(0.2% + 2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1.2%+ 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Continuity test: acoustic indication; <25Ω Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 100x203x50mm Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function Illumination: yes Optional equipment: FLK-C25 soft cover Temperature measurement resolution: 0.1°C Temperature measuring range: -40...537°C True effective value measurement: True RMS Test voltage: 50V; 100V AC current measuring range: 10µA...60mA; 400mA Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Diode test: 1mA @6V Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 10kΩ...100MΩ Frequency measuring accuracy: ±(0.1%+1 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP40 |
на замовлення 4 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
FLUKE-123B/EU | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div IP rating: IP51 Number of channels: 2 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Display resolution: 640x480 Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Additional functions: multimeter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Manufacturer series: FLUKE 120B Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Band: 20MHz Time base: 20n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Kind of display used: colour; LCD TFT 5,7" Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +15 |
FLUKE-123B/EU/S | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div IP rating: IP51 Number of channels: 2 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Display resolution: 640x480 Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Additional functions: multimeter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Manufacturer series: FLUKE 120B Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Band: 20MHz Time base: 20n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Kind of display used: colour; LCD TFT 5,7" Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +16 |
FLUKE-124B/EU | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 IP rating: IP51 Number of channels: 2 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Display resolution: 640x480 Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Additional functions: multimeter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Manufacturer series: FLUKE 120B Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Time base: 10n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +15 |
FLUKE-124B/EU/S | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 IP rating: IP51 Number of channels: 2 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Display resolution: 640x480 Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Additional functions: multimeter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Manufacturer series: FLUKE 120B Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Time base: 10n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-125B/EU | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 IP rating: IP51 Number of channels: 2 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Display resolution: 640x480 Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Additional functions: multimeter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Manufacturer series: FLUKE 120B Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Time base: 10n...60s/div Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +16 |
FLUKE-125B/EU/S | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 IP rating: IP51 Number of channels: 2 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Display resolution: 640x480 Dimensions: 259x132x55mm Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Additional functions: multimeter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Manufacturer series: FLUKE 120B Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Time base: 10n...60s/div Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
FLUKE-1587 FC | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Power supply: battery LR6 AA 1,5V x4 IP rating: IP40 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-C25 soft cover Continuity test: acoustic indication; <25Ω Temperature measurement resolution: 0.1°C Temperature measuring range: -40...537°C True effective value measurement: True RMS AC Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature Dimensions (W x H x D): 100x203x50mm Test voltage: 500V AC current measuring range: 10µA...60mA; 400mA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @6V Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 2 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD |
на замовлення 23 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +13 |
FLK-115/TLK-225-1 | FLUKE |
![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set Conform to the norm: CAT III 600V; EN 61010 Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Continuity test: acoustic indication; <20Ω Pollution degree: 2 Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 84x167x46mm AC current measuring range: 1mA...6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.2mA @2.7V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 |
на замовлення 92 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-27II/EUR | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67 IP rating: IP67 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Kind of display used: LCD Power supply: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: test leads Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case Type of meter: digital multimeter Weight with battery: 517g Continuity test: acoustic indication Duty cycle factor: 0...99.9% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Temperature measuring range: -200...1090°C Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Dimensions (W x H x D): 100x198x63.5mm AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @2.8V Display parameters: (6000) Frequency measuring accuracy: ±(0.005%+1 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) AC current measuring accuracy: ±(1.5% + 2 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +12 |
FLUKE-365/E | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 18mm; LCD Type of meter: multifunction AC voltage measuring accuracy: ±(1% + 5 digit) AC voltage measuring range: 100mV...600V DC voltage measuring accuracy: ±(1.5% + 5 digit) DC voltage measuring range: 100mV...600V Resistance measuring accuracy: ±(1%+5 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ True effective value measurement: True RMS Standard equipment: case; fixed test leads; FLK-TL75 test leads Measuring instrument features: automatic power-off; current clamp can be detached from the meter for measurements in hard-to-reach places; LED for measurement spot illumination Kind of display used: LCD Measurement: AC current; AC voltage; DC current; DC voltage; resistance Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Illumination: yes Continuity test: acoustic indication; <30Ω DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 225x65x46mm Additional functions: torch Weight with battery: 275g Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285; FLK-C43 soft cover; FLK-TL220 set; test leads FLK-TL71; test leads FLK-TL224 SureGrip Max. diameter of measured cable: 18mm Kind of meter: digital; pincers type AC current measuring range: 100mA...200A DC current measuring range: 100mA...200A AC current measuring accuracy: ±(2% + 5 digit) |
на замовлення 7 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +7 |
FLUKE-28II/EUR | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Kind of display used: LCD Display parameters: (6000) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring accuracy: ±(1% + 2 digit) True effective value measurement: True RMS Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Duty cycle factor: 0...99.9% Continuity test: acoustic indication IP rating: IP67 Weight with battery: 517g Power supply: battery LR6 AA 1,5V x3 Standard equipment: test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 100x198x63.5mm Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Illumination: yes Bargraph: 33 segm. 40x/s Diode test: 1mA @2.8V Conductance measuring accuracy: ±(1% + 10digit) Temperature measurement accuracy: ±(1% + 10 digit) Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Temperature measuring range: -200...1090°C |
на замовлення 5 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-28IIEX | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/19999) Bargraph: 33 segm. 40x/s True effective value measurement: True RMS DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Resistance measuring accuracy: ±(0.2%+1 digit) Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) Diode test: 1mA @2.8V Continuity test: acoustic indication Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x3 Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Standard equipment: test leads Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Duty cycle factor: 0...99.9% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71 Weight with battery: 517g Dimensions (W x H x D): 100x198x63.5mm Illumination: yes Battery/ rechargeable battery: battery LR03 AAA 1,5V x3 IP rating: IP67 Conductance measuring accuracy: ±(1% + 10digit) |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +10 |
FLUKE-381 | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x5 Body dimensions: 277x88x43mm Illumination: yes Related items: POM-5913; POM-6173A; POM-7519A Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m) Type of meter: multifunction Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set Continuity test: acoustic indication; <30Ω Max. diameter of measured cable: 34mm True effective value measurement: True RMS Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance Kind of meter: digital; pincers type AC current measuring range: 100mA...1kA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC current measuring range: 100mA...1kA DC voltage measuring range: 100mV...600V; 1kV AC voltage measuring range: 100mV...600V; 1kV Frequency measuring range: 5...500Hz CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Frequency measuring accuracy: ±(0.5%+5 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1.5% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) |
на замовлення 7 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +5 |
FLUKE-83-5/EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) Illumination: yes True effective value measurement: True RMS AC DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.1% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(0.7% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.4% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1.2% + 2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Resistance measuring accuracy: ±(0.4%+1 digit) Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Diode test: 1mA @3V Continuity test: acoustic indication Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation Bargraph: 33 segm. 40x/s Battery/ rechargeable battery: battery 6F22 9V x1 Conductance measuring accuracy: ±(1% + 10digit) Dimensions (W x H x D): 95x200x48mm Power supply: battery 6F22 9V x1 IP rating: IP30 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Weight with battery: 600g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Pollution degree: 2 Conductance measurement: 0.01...60S |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +6 |
FLUKE-87-5/EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/20000) Bargraph: 33 segm. 40x/s True effective value measurement: True RMS AC DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(0.7% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Resistance measuring accuracy: ±(0.2%+1 digit) Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) Diode test: 1mA @3V Continuity test: acoustic indication Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Power supply: battery 6F22 9V x1 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Weight with battery: 600g Dimensions (W x H x D): 95x200x48mm Illumination: yes Battery/ rechargeable battery: battery 6F22 9V x1 IP rating: IP30 Conductance measuring accuracy: ±(1% + 10digit) |
на замовлення 41 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE-87V-MAX | FLUKE |
![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Power supply: battery LR6 AA 1,5V x3 IP rating: IP67 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Type of meter: digital multimeter Weight with battery: 700g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Temperature measuring range: -200...1090°C True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Dimensions (W x H x D): 63x198x100mm AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @3V Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Display parameters: (6000/20000) Frequency measuring accuracy: ±(0.005%+1 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD |
на замовлення 7 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
FLUKE-87V-MAX/E2 KIT | FLUKE |
![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Power supply: battery LR6 AA 1,5V x3 IP rating: IP67 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Type of meter: digital multimeter Weight with battery: 700g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Temperature measuring range: -200...1090°C True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Dimensions (W x H x D): 63x198x100mm AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @3V Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Display parameters: (6000/20000) Frequency measuring accuracy: ±(0.005%+1 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD |
на замовлення 4 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
FLK-87VMAX-PVLEAD1 | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67 Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000/20000) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(0.7% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.2% + 4 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 2 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Continuity test: acoustic indication IP rating: IP67 Weight with battery: 700g Power supply: battery LR6 AA 1,5V x3 Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Dimensions (W x H x D): 63x198x100mm Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Illumination: yes Bargraph: 33 segm. 40x/s Diode test: 1mA @3V Conductance measuring accuracy: ±(1% + 10digit) Temperature measurement accuracy: ±(1% + 10 digit) Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Temperature measuring range: -200...1090°C |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +9 |
FLUKE-374 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Kind of display used: LCD Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Dimensions: 246x83x43mm Related items: POM-5913; POM-6173A; POM-7519A Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless Type of meter: multifunction Weight with battery: 388g Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Test: diodes Continuity test: acoustic indication; <30Ω Pollution degree: 2 Max. diameter of measured cable: 34mm True effective value measurement: True RMS Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance Kind of meter: digital; pincers type AC current measuring range: 100mA...600A Resistance measuring range: 100mΩ...600Ω; 6kΩ DC current measuring range: 100mA...600A DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Frequency measuring range: 5...500Hz Capacitance measuring range: 0.1...100µF; 1mF CF crest factor: 2.5 @ 600A Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Software: Fluke Connect Frequency measuring accuracy: ±(0.5%+5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) |
на замовлення 13 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +9 |
FLUKE-375 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Kind of display used: LCD Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Dimensions: 246x83x43mm Related items: POM-5913; POM-6173A; POM-7519A Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless Type of meter: multifunction Weight with battery: 388g Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Test: diodes Continuity test: acoustic indication; <30Ω Pollution degree: 2 Max. diameter of measured cable: 34mm True effective value measurement: True RMS Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Kind of meter: digital; pincers type AC current measuring range: 100mA...600A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC current measuring range: 100mA...600A DC voltage measuring range: 100mV...1kV AC voltage measuring range: 0.1mV...1kV Frequency measuring range: 5...500Hz Capacitance measuring range: 0.1...100µF; 1mF CF crest factor: 2.5 @ 600A Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Software: Fluke Connect Frequency measuring accuracy: ±(0.5%+5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) |
на замовлення 14 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +12 |
FLUKE-376 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Kind of display used: LCD Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Dimensions: 246x83x43mm Related items: POM-5913; POM-6173A; POM-7519A Standard equipment: case; flexible current probe; FLK-TL75 test leads Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless Type of meter: multifunction Weight with battery: 388g Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Continuity test: acoustic indication; <30Ω Pollution degree: 2 Max. diameter of measured cable: 34mm True effective value measurement: True RMS Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Kind of meter: digital; pincers type AC current measuring range: 100mA...1kA Resistance measuring range: 0.1...60kΩ DC current measuring range: 100mA...1kA DC voltage measuring range: 0.1mV...1kV AC voltage measuring range: 100mV...1kV Frequency measuring range: 100mHz...500Hz Capacitance measuring range: 1...1000µF CF crest factor: 2.5 @ 600A Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Software: Fluke Connect Frequency measuring accuracy: ±(0.5%+5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) |
на замовлення 122 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +7 |
FLUKE-902 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Kind of display used: LCD Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 600V; EN 61010 Resistance to: shockproof Illumination: yes Dimensions: 240x80x40mm Related items: POM-5900A/POM; POM-5907A; POM-6041B Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function Type of meter: multifunction Weight with battery: 310g Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip Continuity test: acoustic indication; <30Ω Measuring instruments application: heating and air-conditioning technology Max. diameter of measured cable: 30mm True effective value measurement: True RMS AC Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Kind of meter: digital; pincers type AC current measuring range: 100mA...600A Resistance measuring range: 100mΩ...999Ω; 9.999kΩ DC current measuring range: 0.1...200µA DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Capacitance measuring range: 0.1...100µF; 1mF Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Software: Fluke Connect Capacitance measuring accuracy: ±(1.9%+ 2 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(1% + 5 digit) AC voltage measuring accuracy: ±(1% + 5 digit) Resistance measuring accuracy: ±(1.5%+5 digit) |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +7 |
FLUKE-323 | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30 Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x2 IP rating: IP30 Conform to the norm: CAT III 600V; EN 61010 Dimensions: 207x75x34mm Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A Standard equipment: case; test leads Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator Type of meter: multifunction Weight with battery: 265g Optional equipment: FLK-TL223 accessory set Continuity test: acoustic indication; <70Ω Max. diameter of measured cable: 30mm Current measuring resolution: 0.1A True effective value measurement: True RMS Measurement: AC current; AC voltage; DC voltage; resistance Kind of meter: digital; pincers type Bandwidth for AC voltage measurements: 45...400Hz AC current measuring range: 100mA...400A Resistance measuring range: 100mΩ...400Ω; 4kΩ Bandwidth for AC current measurements: 45...400Hz DC voltage measuring range: 100mV...400V; 600V AC voltage measuring range: 100mV...400V; 600V Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: 3,5 digit AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) |
на замовлення 25 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +9 |
FLUKE-325 | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Kind of display used: LCD Power supply: battery LR03 AAA 1,5V x2 IP rating: IP30 Conform to the norm: CAT III 600V; EN 61010 Illumination: yes Dimensions: 207x75x34mm Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A Standard equipment: case; test leads Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator Type of meter: multifunction Weight with battery: 283g Optional equipment: FLK-TL223 accessory set Continuity test: acoustic indication; <30Ω Max. diameter of measured cable: 30mm Current measuring resolution: 10mA True effective value measurement: True RMS Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Kind of meter: digital; pincers type Bandwidth for AC voltage measurements: 45...400Hz AC current measuring range: 10mA...40A; 400A Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ Bandwidth for AC current measurements: 45...400Hz DC current measuring range: 10mA...40A; 400A DC voltage measuring range: 100mV...400V; 600V AC voltage measuring range: 100mV...400V; 600V Frequency measuring range: 5...500Hz Capacitance measuring range: 0.1...100µF; 1mF Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Display parameters: 3,5 digit Capacitance measuring accuracy: ±(1%+ 4 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) |
на замовлення 89 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +6 |
FLUKE-378 FC/E | FLUKE |
![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Dimensions: 274x86x47mm Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless Type of meter: multifunction Weight with battery: 463g Test: diodes Continuity test: acoustic indication; <30Ω Pollution degree: 2 Max. diameter of measured cable: 34mm True effective value measurement: True RMS Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Kind of meter: digital; pincers type AC current measuring range: 100mA...999.9A Resistance measuring range: 600Ω; 6kΩ; 60kΩ DC current measuring range: 100mA...999.9A DC voltage measuring range: 600V; 1kV AC voltage measuring range: 600V; 1kV Frequency measuring range: 5...500Hz Capacitance measuring range: 0.1...100µF; 1mF CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Software: Fluke Connect Frequency measuring accuracy: ±(0.5%+5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x2 |
на замовлення 11 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
TL71-1 | FLUKE |
Category: Test Leads - Sets Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2 Current rating: 10A Kit contents: test leads x2 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Cable length: 1.5m Wire insulation material: silicone Type of test accessories: test leads Test lead configuration: banana plug 4mm; probe tip Colour: red and black Rated voltage: 1kV |
на замовлення 68 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
TP40 | FLUKE |
![]() Description: Set of measuring probes; 60VDC; Kit: test probes x5 Rated voltage: 60V DC Kit contents: test probes x5 Type of test accessories: set of measuring probes Related items: FLK-TL222; FLK-TL224 |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +10 |
FLUKE-289/FVF/EUR | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; Software: Fluke View Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Type of meter: digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: Fluke View |
на замовлення 8 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
TLK289 EUR | FLUKE |
Category: Test Leads - Sets with Accessories Description: Test leads; red and black Type of test accessories: test leads Colour: red and black Kit contents: clip-on probes FLK-AC220; clip-on probes FLK-AC280; FLK-AC285 aligator clip; soft case FLK-C116; test leads FLK-TL224; test probes FLK-TP220; thermocouple FLK-80BK-A |
на замовлення 11 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +14 |
FLK-289/FVF/IR3000 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; Software: Fluke View Forms Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Type of meter: digital multimeter Software: Fluke View Forms |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
FLUKE-IR3000FC | FLUKE |
![]() ![]() Description: Adapter Bluetooth Body dimensions: 32x76x64mm Type of test accessories: adapter Bluetooth Related items: FLK-287; FLK-289; FLK-789 |
на замовлення 7 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
I2000 FLEX | FLUKE |
![]() ![]() Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V Cable length: 0.5m Type of test accessories: AC current clamp adapter Power supply: battery LR6 AA 1,5V x2 Kind of display used: LCD Max. operating voltage: 600V Standard equipment: BNC to banana plug adapter Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs Weight with battery: 420g Max. diameter of measured cable: 178mm Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A) True effective value measurement: True RMS AC Measurement: AC current AC current measuring range: 1...20A; 200A; 2kA Bandwidth for AC current measurements: 10Hz...20kHz Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Display parameters: (3000) AC current measuring accuracy: ±1% Conform to the norm: CAT III 600V; EN 61010 |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() |
BP120MH | FLUKE |
Category: Accessories for Oscilloscopes - Others Description: Rechargeable battery; 4.8V; 3000mAh Type of test accessories: rechargeable battery Related items: FLK-43B; FLK-123 Capacity: 3Ah Rated voltage: 4.8V |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
FLUKE-726/APAC/EMEA | FLUKE |
![]() ![]() ![]() Description: Meter: calibrator; pressure,frequency,voltage,current,RTD Related items: POM-5900A/POM; POM-5912B; POM-6173A Standard equipment: calibration certificate NIST; crocodile clips FLK-AC72; FLK-TL75 test leads; test leads Measuring instrument features: 24V loop supply voltage; operates with 8 types of RTDs: Pt100 (385), Pt200(385), Pt500(385), Pt1000 (385), Pt100 (3919), Pt100 (3926), Ni120 (672), CU10; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP Type of meter: calibrator Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage Measurement: DC current; DC voltage; resistance Resistance measuring range: 0...4kΩ DC current measuring range: 0...24mA DC voltage measuring range: 0...30V Ω simulation: 0...4kΩ Battery/ rechargeable battery: battery AA 1,5V x4 Current source: 0...24mA Voltage source: 0...20V Power supply: battery AA 1,5V x4 |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
FLUKE-725/APAC/EMEA | FLUKE |
![]() ![]() ![]() Description: Calibrator; pressure,frequency,voltage,current,RTD Illumination: yes Related items: POM-5900A/POM; POM-5912B; POM-6173A Type of device: calibrator Dimensions: 200x96x47mm Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; set of test leads with alligator clips Protection: short circuit protection SCP Measuring instrument features: 24V, 22mA loop supplying; automatic and manual step setting; automatic linear sourcing; measures and sources frequency within 1 cycle/min. to 10kHz range; measures and sources signals simultaneously from 2 channels; measures pressure up to 700 bar using any FLK-700Pxx pressure module; operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP; settings memory Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage Current source accuracy: ±(0,025% + 1 digit) Voltage source accuracy: ±(0,02% + 2 digits) Measurement: DC current; DC voltage; resistance Resistance measuring range: 10mΩ...400Ω; 1.5kΩ; 3.2kΩ DC current measuring range: 0...24mA DC voltage measuring range: 0...100mV; 0...30V Ω simulation: 15...3200Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Current source: 0...24mA Voltage source: 0...20V DC voltage measuring accuracy: ±(0.02% + 2 digit) DC current measuring accuracy: ±(0.02% + 2 digit) Resistance measuring accuracy: ±(0.1%+1Ω) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() |
FLUKE PN648029 | FLUKE |
Category: Single Test Leads Description: Test lead Type of test accessories: test lead Related items: FLK-T5-1000 |
на замовлення 15 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +4 |
FLK-TIS55+ 9HZ | FLUKE |
![]() Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54 Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 256x192 Temperature measuring range: -20...550°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 28° horizontal x 20° vertical Focusing: manual IP rating: IP54 Dimensions: 267x101x145mm Power supply: rechargeable battery Li-Ion x1 Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable Three-dimensional resolution: 1.91mrad Thermal sensitivity (NETD): 40mK Resistance to: fall from 2m height Measurement: temperature Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Software: download from manufacturers website; Fluke Connect Display resolution: 320x240 Touchpad: yes Measuring unit: °C; °F Operating temperature: -10...50°C Interface: LAN; USB; WiFi Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
FLUKE-116 EUR |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Battery/ rechargeable battery: battery 6LR61 9V x1
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Measuring instruments application: heating and air-conditioning technology
Temperature measuring range: -40...400°C
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 0.1...600µA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(0.1% + 2 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Battery/ rechargeable battery: battery 6LR61 9V x1
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Measuring instruments application: heating and air-conditioning technology
Temperature measuring range: -40...400°C
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 0.1...600µA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(0.1% + 2 digit)
на замовлення 5 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 23504.92 грн |
FLUKE-117 EUR |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
на замовлення 78 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 24734.59 грн |
FLUKE-175 EGFID |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.15% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.15% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
на замовлення 34 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 25253.69 грн |
FLUKE-177 EGFID |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
на замовлення 129 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 30788.87 грн |
FLUKE-179 EGFID |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
Temperature measuring range: -40...400°C
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
Temperature measuring range: -40...400°C
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
на замовлення 157 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 36378.52 грн |
FLUKE-1577 |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 62922.96 грн |
2824477 |
Виробник: FLUKE
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
на замовлення 26 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 5295.85 грн |
FLK-3000FC/EDA2 |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 41996.23 грн |
FLUKE-179/EDA2/EUR |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6LR61 9V x1
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6LR61 9V x1
на замовлення 7 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 40026.28 грн |
FLUKE-179/MAG2 KIT |
![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
на замовлення 12 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 35007.73 грн |
FLUKE-T110 |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
на замовлення 54 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 8001.95 грн |
FLUKE T110/VDE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Type of tester: electrical
Additional functions: illumination lamp
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Type of tester: electrical
Additional functions: illumination lamp
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
на замовлення 5 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 7730.44 грн |
FLUKE-T90 |
![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Body dimensions: 245x64x28mm
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 180g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP54
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Body dimensions: 245x64x28mm
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 180g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP54
на замовлення 34 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 5656.50 грн |
FLUKE-T130 |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Measurement: AC voltage; DC voltage
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
на замовлення 48 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 11942.69 грн |
FLUKE T130/VDE |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Measurement: AC voltage; DC voltage
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Bandwidth for AC voltage measurements: 0...400Hz
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
IP rating: IP64
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Measurement: AC voltage; DC voltage
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Bandwidth for AC voltage measurements: 0...400Hz
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
IP rating: IP64
на замовлення 10 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 11681.90 грн |
FLUKE-T150 |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Measurement: AC voltage; DC voltage; resistance
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Measurement: AC voltage; DC voltage; resistance
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
на замовлення 84 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 13561.07 грн |
FLUKE T150/VDE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measurement: AC voltage; DC voltage; resistance
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Body dimensions: 255x78x35mm
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measurement: AC voltage; DC voltage; resistance
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP64
на замовлення 44 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 13603.16 грн |
FLUKE-787B |
![]() ![]() |
Виробник: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Dimensions: 203x100x50mm
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Dimensions: 203x100x50mm
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 114870.47 грн |
FLUKE-789/E |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Dimensions: 203x100x50mm
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Dimensions: 203x100x50mm
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 131554.41 грн |
FLUKE-88-5/A KIT |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
DC current measuring range: 0...10A
AC current measuring range: 0...10A
True effective value measurement: True RMS AC
Resistance measuring range: 0...50MΩ
Capacitance measuring range: 0...10000µF
Frequency measuring range: 0...200kHz
Continuity test: acoustic indication
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 86x186x32mm
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Battery/ rechargeable battery: battery 6F22 9V x1
Bargraph: yes
Diode test: 3V
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Temperature measuring range: -200...1090°C
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
DC current measuring range: 0...10A
AC current measuring range: 0...10A
True effective value measurement: True RMS AC
Resistance measuring range: 0...50MΩ
Capacitance measuring range: 0...10000µF
Frequency measuring range: 0...200kHz
Continuity test: acoustic indication
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 86x186x32mm
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Battery/ rechargeable battery: battery 6F22 9V x1
Bargraph: yes
Diode test: 3V
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Temperature measuring range: -200...1090°C
на замовлення 3 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 69777.77 грн |
FLUKE-279FC/IFLEX |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Refresh rate: 8Hz
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Type of meter: digital multimeter with infrared camera
Continuity test: acoustic indication; <25Ω
Non-contact temperature measuring range: -10...200°C
Emissivity value: 0,95 (fixed)
Focusing: focus free
Camera resolution: 80x60
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Capacitance measuring range: 1000nF...9999µF
Diode test: 2V
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Europe; Great Britain
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Refresh rate: 8Hz
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Type of meter: digital multimeter with infrared camera
Continuity test: acoustic indication; <25Ω
Non-contact temperature measuring range: -10...200°C
Emissivity value: 0,95 (fixed)
Focusing: focus free
Camera resolution: 80x60
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Capacitance measuring range: 1000nF...9999µF
Diode test: 2V
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Europe; Great Britain
на замовлення 3 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 95655.38 грн |
FLK-3000FC |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP54
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Weight with battery: 340g
Continuity test: acoustic indication
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 93x207x48mm
AC current measuring range: 60mA; 400mA
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 60mA; 400mA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
Diode test: 2V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Software: compatible Android; Fluke Connect
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
IP rating: IP54
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Weight with battery: 340g
Continuity test: acoustic indication
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 93x207x48mm
AC current measuring range: 60mA; 400mA
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 60mA; 400mA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
Diode test: 2V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Software: compatible Android; Fluke Connect
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
на замовлення 4 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 31600.13 грн |
FLUKE-1587 T |
![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Type of meter: digital multimeter
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 10µA...60mA; 400mA
DC current measuring accuracy: ±(0.2% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Continuity test: acoustic indication; <25Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 100x203x50mm
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Illumination: yes
Optional equipment: FLK-C25 soft cover
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP40
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Type of meter: digital multimeter
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 10µA...60mA; 400mA
DC current measuring accuracy: ±(0.2% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Continuity test: acoustic indication; <25Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 100x203x50mm
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Illumination: yes
Optional equipment: FLK-C25 soft cover
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP40
на замовлення 4 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 70483.39 грн |
FLUKE-123B/EU |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Band: 20MHz
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Band: 20MHz
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
на замовлення 3 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 161508.10 грн |
FLUKE-123B/EU/S |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Band: 20MHz
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Band: 20MHz
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 214076.21 грн |
FLUKE-124B/EU |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 196788.99 грн |
FLUKE-124B/EU/S |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 245717.62 грн |
FLUKE-125B/EU |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 234421.95 грн |
FLUKE-125B/EU/S |
![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
IP rating: IP51
Number of channels: 2
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Display resolution: 640x480
Dimensions: 259x132x55mm
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Additional functions: multimeter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Manufacturer series: FLUKE 120B
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 277958.99 грн |
FLUKE-1587 FC |
![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
на замовлення 23 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 77069.15 грн |
FLK-115/TLK-225-1 |
![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Conform to the norm: CAT III 600V; EN 61010
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Conform to the norm: CAT III 600V; EN 61010
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
на замовлення 92 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 23206.99 грн |
FLUKE-27II/EUR |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
IP rating: IP67
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: test leads
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Type of meter: digital multimeter
Weight with battery: 517g
Continuity test: acoustic indication
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Dimensions (W x H x D): 100x198x63.5mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.8V
Display parameters: (6000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
IP rating: IP67
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: test leads
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Type of meter: digital multimeter
Weight with battery: 517g
Continuity test: acoustic indication
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Dimensions (W x H x D): 100x198x63.5mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.8V
Display parameters: (6000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 59737.37 грн |
FLUKE-365/E |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 18mm; LCD
Type of meter: multifunction
AC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC voltage measuring range: 100mV...600V
Resistance measuring accuracy: ±(1%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ
True effective value measurement: True RMS
Standard equipment: case; fixed test leads; FLK-TL75 test leads
Measuring instrument features: automatic power-off; current clamp can be detached from the meter for measurements in hard-to-reach places; LED for measurement spot illumination
Kind of display used: LCD
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Illumination: yes
Continuity test: acoustic indication; <30Ω
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 225x65x46mm
Additional functions: torch
Weight with battery: 275g
Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285; FLK-C43 soft cover; FLK-TL220 set; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Max. diameter of measured cable: 18mm
Kind of meter: digital; pincers type
AC current measuring range: 100mA...200A
DC current measuring range: 100mA...200A
AC current measuring accuracy: ±(2% + 5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 18mm; LCD
Type of meter: multifunction
AC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 100mV...600V
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC voltage measuring range: 100mV...600V
Resistance measuring accuracy: ±(1%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ
True effective value measurement: True RMS
Standard equipment: case; fixed test leads; FLK-TL75 test leads
Measuring instrument features: automatic power-off; current clamp can be detached from the meter for measurements in hard-to-reach places; LED for measurement spot illumination
Kind of display used: LCD
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Illumination: yes
Continuity test: acoustic indication; <30Ω
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 225x65x46mm
Additional functions: torch
Weight with battery: 275g
Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285; FLK-C43 soft cover; FLK-TL220 set; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Max. diameter of measured cable: 18mm
Kind of meter: digital; pincers type
AC current measuring range: 100mA...200A
DC current measuring range: 100mA...200A
AC current measuring accuracy: ±(2% + 5 digit)
на замовлення 7 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 27510.85 грн |
FLUKE-28II/EUR |
![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Duty cycle factor: 0...99.9%
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Bargraph: 33 segm. 40x/s
Diode test: 1mA @2.8V
Conductance measuring accuracy: ±(1% + 10digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Duty cycle factor: 0...99.9%
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Bargraph: 33 segm. 40x/s
Diode test: 1mA @2.8V
Conductance measuring accuracy: ±(1% + 10digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
на замовлення 5 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 60499.93 грн |
FLUKE-28IIEX |
![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
True effective value measurement: True RMS
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Diode test: 1mA @2.8V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Weight with battery: 517g
Dimensions (W x H x D): 100x198x63.5mm
Illumination: yes
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
IP rating: IP67
Conductance measuring accuracy: ±(1% + 10digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
True effective value measurement: True RMS
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Diode test: 1mA @2.8V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Weight with battery: 517g
Dimensions (W x H x D): 100x198x63.5mm
Illumination: yes
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
IP rating: IP67
Conductance measuring accuracy: ±(1% + 10digit)
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 142763.42 грн |
FLUKE-381 |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x5
Body dimensions: 277x88x43mm
Illumination: yes
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Type of meter: multifunction
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Continuity test: acoustic indication; <30Ω
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...1kA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Frequency measuring accuracy: ±(0.5%+5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x5
Body dimensions: 277x88x43mm
Illumination: yes
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Type of meter: multifunction
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Continuity test: acoustic indication; <30Ω
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...1kA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Frequency measuring accuracy: ±(0.5%+5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
на замовлення 7 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 61895.48 грн |
FLUKE-83-5/EUR |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Illumination: yes
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.4% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1.2% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.4%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Diode test: 1mA @3V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Bargraph: 33 segm. 40x/s
Battery/ rechargeable battery: battery 6F22 9V x1
Conductance measuring accuracy: ±(1% + 10digit)
Dimensions (W x H x D): 95x200x48mm
Power supply: battery 6F22 9V x1
IP rating: IP30
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Pollution degree: 2
Conductance measurement: 0.01...60S
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Illumination: yes
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.4% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1.2% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.4%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Diode test: 1mA @3V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Bargraph: 33 segm. 40x/s
Battery/ rechargeable battery: battery 6F22 9V x1
Conductance measuring accuracy: ±(1% + 10digit)
Dimensions (W x H x D): 95x200x48mm
Power supply: battery 6F22 9V x1
IP rating: IP30
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Pollution degree: 2
Conductance measurement: 0.01...60S
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 48301.40 грн |
FLUKE-87-5/EUR |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Bargraph: 33 segm. 40x/s
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Diode test: 1mA @3V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Weight with battery: 600g
Dimensions (W x H x D): 95x200x48mm
Illumination: yes
Battery/ rechargeable battery: battery 6F22 9V x1
IP rating: IP30
Conductance measuring accuracy: ±(1% + 10digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Bargraph: 33 segm. 40x/s
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Diode test: 1mA @3V
Continuity test: acoustic indication
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Weight with battery: 600g
Dimensions (W x H x D): 95x200x48mm
Illumination: yes
Battery/ rechargeable battery: battery 6F22 9V x1
IP rating: IP30
Conductance measuring accuracy: ±(1% + 10digit)
на замовлення 41 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 43558.49 грн |
FLUKE-87V-MAX |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
на замовлення 7 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 55142.18 грн |
FLUKE-87V-MAX/E2 KIT |
![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Power supply: battery LR6 AA 1,5V x3
IP rating: IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
на замовлення 4 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 64834.32 грн |
FLK-87VMAX-PVLEAD1 |
Виробник: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/20000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.2% + 4 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 700g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 63x198x100mm
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Bargraph: 33 segm. 40x/s
Diode test: 1mA @3V
Conductance measuring accuracy: ±(1% + 10digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/20000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.2% + 4 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 700g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 63x198x100mm
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Bargraph: 33 segm. 40x/s
Diode test: 1mA @3V
Conductance measuring accuracy: ±(1% + 10digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Temperature measuring range: -200...1090°C
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 63834.07 грн |
FLUKE-374 FC |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 246x83x43mm
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 388g
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...600A
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 2.5 @ 600A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 246x83x43mm
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 388g
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...600A
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 2.5 @ 600A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
на замовлення 13 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 38681.07 грн |
FLUKE-375 FC |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 246x83x43mm
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 388g
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...600A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...1kV
AC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 2.5 @ 600A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 246x83x43mm
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 388g
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...600A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...1kV
AC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 2.5 @ 600A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
на замовлення 14 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 44979.64 грн |
FLUKE-376 FC |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 246x83x43mm
Related items: POM-5913; POM-6173A; POM-7519A
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 388g
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...1kA
Resistance measuring range: 0.1...60kΩ
DC current measuring range: 100mA...1kA
DC voltage measuring range: 0.1mV...1kV
AC voltage measuring range: 100mV...1kV
Frequency measuring range: 100mHz...500Hz
Capacitance measuring range: 1...1000µF
CF crest factor: 2.5 @ 600A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 246x83x43mm
Related items: POM-5913; POM-6173A; POM-7519A
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 388g
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...1kA
Resistance measuring range: 0.1...60kΩ
DC current measuring range: 100mA...1kA
DC voltage measuring range: 0.1mV...1kV
AC voltage measuring range: 100mV...1kV
Frequency measuring range: 100mHz...500Hz
Capacitance measuring range: 1...1000µF
CF crest factor: 2.5 @ 600A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
на замовлення 122 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 49223.24 грн |
FLUKE-902 FC |
![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 600V; EN 61010
Resistance to: shockproof
Illumination: yes
Dimensions: 240x80x40mm
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Type of meter: multifunction
Weight with battery: 310g
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Continuity test: acoustic indication; <30Ω
Measuring instruments application: heating and air-conditioning technology
Max. diameter of measured cable: 30mm
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of meter: digital; pincers type
AC current measuring range: 100mA...600A
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
DC current measuring range: 0.1...200µA
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Capacitance measuring range: 0.1...100µF; 1mF
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1.5%+5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 600V; EN 61010
Resistance to: shockproof
Illumination: yes
Dimensions: 240x80x40mm
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Type of meter: multifunction
Weight with battery: 310g
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Continuity test: acoustic indication; <30Ω
Measuring instruments application: heating and air-conditioning technology
Max. diameter of measured cable: 30mm
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of meter: digital; pincers type
AC current measuring range: 100mA...600A
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
DC current measuring range: 0.1...200µA
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Capacitance measuring range: 0.1...100µF; 1mF
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1.5%+5 digit)
на замовлення 3 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 31542.36 грн |
FLUKE-323 |
![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP30
Conform to the norm: CAT III 600V; EN 61010
Dimensions: 207x75x34mm
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Standard equipment: case; test leads
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Type of meter: multifunction
Weight with battery: 265g
Optional equipment: FLK-TL223 accessory set
Continuity test: acoustic indication; <70Ω
Max. diameter of measured cable: 30mm
Current measuring resolution: 0.1A
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC voltage; resistance
Kind of meter: digital; pincers type
Bandwidth for AC voltage measurements: 45...400Hz
AC current measuring range: 100mA...400A
Resistance measuring range: 100mΩ...400Ω; 4kΩ
Bandwidth for AC current measurements: 45...400Hz
DC voltage measuring range: 100mV...400V; 600V
AC voltage measuring range: 100mV...400V; 600V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP30
Conform to the norm: CAT III 600V; EN 61010
Dimensions: 207x75x34mm
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Standard equipment: case; test leads
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Type of meter: multifunction
Weight with battery: 265g
Optional equipment: FLK-TL223 accessory set
Continuity test: acoustic indication; <70Ω
Max. diameter of measured cable: 30mm
Current measuring resolution: 0.1A
True effective value measurement: True RMS
Measurement: AC current; AC voltage; DC voltage; resistance
Kind of meter: digital; pincers type
Bandwidth for AC voltage measurements: 45...400Hz
AC current measuring range: 100mA...400A
Resistance measuring range: 100mΩ...400Ω; 4kΩ
Bandwidth for AC current measurements: 45...400Hz
DC voltage measuring range: 100mV...400V; 600V
AC voltage measuring range: 100mV...400V; 600V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
на замовлення 25 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 12113.52 грн |
FLUKE-325 |
![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP30
Conform to the norm: CAT III 600V; EN 61010
Illumination: yes
Dimensions: 207x75x34mm
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Standard equipment: case; test leads
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Type of meter: multifunction
Weight with battery: 283g
Optional equipment: FLK-TL223 accessory set
Continuity test: acoustic indication; <30Ω
Max. diameter of measured cable: 30mm
Current measuring resolution: 10mA
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Kind of meter: digital; pincers type
Bandwidth for AC voltage measurements: 45...400Hz
AC current measuring range: 10mA...40A; 400A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
Bandwidth for AC current measurements: 45...400Hz
DC current measuring range: 10mA...40A; 400A
DC voltage measuring range: 100mV...400V; 600V
AC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x2
IP rating: IP30
Conform to the norm: CAT III 600V; EN 61010
Illumination: yes
Dimensions: 207x75x34mm
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Standard equipment: case; test leads
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Type of meter: multifunction
Weight with battery: 283g
Optional equipment: FLK-TL223 accessory set
Continuity test: acoustic indication; <30Ω
Max. diameter of measured cable: 30mm
Current measuring resolution: 10mA
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Kind of meter: digital; pincers type
Bandwidth for AC voltage measurements: 45...400Hz
AC current measuring range: 10mA...40A; 400A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
Bandwidth for AC current measurements: 45...400Hz
DC current measuring range: 10mA...40A; 400A
DC voltage measuring range: 100mV...400V; 600V
AC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Display parameters: 3,5 digit
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
на замовлення 89 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 21189.17 грн |
FLUKE-378 FC/E |
![]() |
Виробник: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 274x86x47mm
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 463g
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...999.9A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...999.9A
DC voltage measuring range: 600V; 1kV
AC voltage measuring range: 600V; 1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Dimensions: 274x86x47mm
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
Type of meter: multifunction
Weight with battery: 463g
Test: diodes
Continuity test: acoustic indication; <30Ω
Pollution degree: 2
Max. diameter of measured cable: 34mm
True effective value measurement: True RMS
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Kind of meter: digital; pincers type
AC current measuring range: 100mA...999.9A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC current measuring range: 100mA...999.9A
DC voltage measuring range: 600V; 1kV
AC voltage measuring range: 600V; 1kV
Frequency measuring range: 5...500Hz
Capacitance measuring range: 0.1...100µF; 1mF
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Software: Fluke Connect
Frequency measuring accuracy: ±(0.5%+5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x2
на замовлення 11 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 57597.40 грн |
TL71-1 |
Виробник: FLUKE
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Current rating: 10A
Kit contents: test leads x2
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Cable length: 1.5m
Wire insulation material: silicone
Type of test accessories: test leads
Test lead configuration: banana plug 4mm; probe tip
Colour: red and black
Rated voltage: 1kV
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Current rating: 10A
Kit contents: test leads x2
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Cable length: 1.5m
Wire insulation material: silicone
Type of test accessories: test leads
Test lead configuration: banana plug 4mm; probe tip
Colour: red and black
Rated voltage: 1kV
на замовлення 68 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 3402.65 грн |
TP40 |
![]() |
Виробник: FLUKE
Category: Probes - Test Plugs
Description: Set of measuring probes; 60VDC; Kit: test probes x5
Rated voltage: 60V DC
Kit contents: test probes x5
Type of test accessories: set of measuring probes
Related items: FLK-TL222; FLK-TL224
Category: Probes - Test Plugs
Description: Set of measuring probes; 60VDC; Kit: test probes x5
Rated voltage: 60V DC
Kit contents: test probes x5
Type of test accessories: set of measuring probes
Related items: FLK-TL222; FLK-TL224
на замовлення 3 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 4973.99 грн |
FLUKE-289/FVF/EUR |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke View
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke View
на замовлення 8 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 79834.68 грн |
TLK289 EUR |
Виробник: FLUKE
Category: Test Leads - Sets with Accessories
Description: Test leads; red and black
Type of test accessories: test leads
Colour: red and black
Kit contents: clip-on probes FLK-AC220; clip-on probes FLK-AC280; FLK-AC285 aligator clip; soft case FLK-C116; test leads FLK-TL224; test probes FLK-TP220; thermocouple FLK-80BK-A
Category: Test Leads - Sets with Accessories
Description: Test leads; red and black
Type of test accessories: test leads
Colour: red and black
Kit contents: clip-on probes FLK-AC220; clip-on probes FLK-AC280; FLK-AC285 aligator clip; soft case FLK-C116; test leads FLK-TL224; test probes FLK-TP220; thermocouple FLK-80BK-A
на замовлення 11 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 19699.53 грн |
FLK-289/FVF/IR3000 |
Виробник: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Software: Fluke View Forms
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Software: Fluke View Forms
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 94252.40 грн |
FLUKE-IR3000FC |
![]() ![]() |
Виробник: FLUKE
Category: Accessories - Others
Description: Adapter Bluetooth
Body dimensions: 32x76x64mm
Type of test accessories: adapter Bluetooth
Related items: FLK-287; FLK-289; FLK-789
Category: Accessories - Others
Description: Adapter Bluetooth
Body dimensions: 32x76x64mm
Type of test accessories: adapter Bluetooth
Related items: FLK-287; FLK-289; FLK-789
на замовлення 7 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 16166.49 грн |
I2000 FLEX |
![]() ![]() |
Виробник: FLUKE
Category: Meters and AC Clamp Probes
Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V
Cable length: 0.5m
Type of test accessories: AC current clamp adapter
Power supply: battery LR6 AA 1,5V x2
Kind of display used: LCD
Max. operating voltage: 600V
Standard equipment: BNC to banana plug adapter
Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs
Weight with battery: 420g
Max. diameter of measured cable: 178mm
Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A)
True effective value measurement: True RMS AC
Measurement: AC current
AC current measuring range: 1...20A; 200A; 2kA
Bandwidth for AC current measurements: 10Hz...20kHz
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Display parameters: (3000)
AC current measuring accuracy: ±1%
Conform to the norm: CAT III 600V; EN 61010
Category: Meters and AC Clamp Probes
Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V
Cable length: 0.5m
Type of test accessories: AC current clamp adapter
Power supply: battery LR6 AA 1,5V x2
Kind of display used: LCD
Max. operating voltage: 600V
Standard equipment: BNC to banana plug adapter
Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs
Weight with battery: 420g
Max. diameter of measured cable: 178mm
Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A)
True effective value measurement: True RMS AC
Measurement: AC current
AC current measuring range: 1...20A; 200A; 2kA
Bandwidth for AC current measurements: 10Hz...20kHz
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Display parameters: (3000)
AC current measuring accuracy: ±1%
Conform to the norm: CAT III 600V; EN 61010
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 36009.62 грн |
BP120MH |
Виробник: FLUKE
Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; 4.8V; 3000mAh
Type of test accessories: rechargeable battery
Related items: FLK-43B; FLK-123
Capacity: 3Ah
Rated voltage: 4.8V
Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; 4.8V; 3000mAh
Type of test accessories: rechargeable battery
Related items: FLK-43B; FLK-123
Capacity: 3Ah
Rated voltage: 4.8V
товару немає в наявності
В кошику
од. на суму грн.
FLUKE-726/APAC/EMEA |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Calibrators
Description: Meter: calibrator; pressure,frequency,voltage,current,RTD
Related items: POM-5900A/POM; POM-5912B; POM-6173A
Standard equipment: calibration certificate NIST; crocodile clips FLK-AC72; FLK-TL75 test leads; test leads
Measuring instrument features: 24V loop supply voltage; operates with 8 types of RTDs: Pt100 (385), Pt200(385), Pt500(385), Pt1000 (385), Pt100 (3919), Pt100 (3926), Ni120 (672), CU10; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP
Type of meter: calibrator
Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage
Measurement: DC current; DC voltage; resistance
Resistance measuring range: 0...4kΩ
DC current measuring range: 0...24mA
DC voltage measuring range: 0...30V
Ω simulation: 0...4kΩ
Battery/ rechargeable battery: battery AA 1,5V x4
Current source: 0...24mA
Voltage source: 0...20V
Power supply: battery AA 1,5V x4
Category: Calibrators
Description: Meter: calibrator; pressure,frequency,voltage,current,RTD
Related items: POM-5900A/POM; POM-5912B; POM-6173A
Standard equipment: calibration certificate NIST; crocodile clips FLK-AC72; FLK-TL75 test leads; test leads
Measuring instrument features: 24V loop supply voltage; operates with 8 types of RTDs: Pt100 (385), Pt200(385), Pt500(385), Pt1000 (385), Pt100 (3919), Pt100 (3926), Ni120 (672), CU10; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP
Type of meter: calibrator
Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage
Measurement: DC current; DC voltage; resistance
Resistance measuring range: 0...4kΩ
DC current measuring range: 0...24mA
DC voltage measuring range: 0...30V
Ω simulation: 0...4kΩ
Battery/ rechargeable battery: battery AA 1,5V x4
Current source: 0...24mA
Voltage source: 0...20V
Power supply: battery AA 1,5V x4
товару немає в наявності
В кошику
од. на суму грн.
FLUKE-725/APAC/EMEA |
![]() ![]() ![]() |
Виробник: FLUKE
Category: Calibrators
Description: Calibrator; pressure,frequency,voltage,current,RTD
Illumination: yes
Related items: POM-5900A/POM; POM-5912B; POM-6173A
Type of device: calibrator
Dimensions: 200x96x47mm
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; set of test leads with alligator clips
Protection: short circuit protection SCP
Measuring instrument features: 24V, 22mA loop supplying; automatic and manual step setting; automatic linear sourcing; measures and sources frequency within 1 cycle/min. to 10kHz range; measures and sources signals simultaneously from 2 channels; measures pressure up to 700 bar using any FLK-700Pxx pressure module; operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP; settings memory
Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage
Current source accuracy: ±(0,025% + 1 digit)
Voltage source accuracy: ±(0,02% + 2 digits)
Measurement: DC current; DC voltage; resistance
Resistance measuring range: 10mΩ...400Ω; 1.5kΩ; 3.2kΩ
DC current measuring range: 0...24mA
DC voltage measuring range: 0...100mV; 0...30V
Ω simulation: 15...3200Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Current source: 0...24mA
Voltage source: 0...20V
DC voltage measuring accuracy: ±(0.02% + 2 digit)
DC current measuring accuracy: ±(0.02% + 2 digit)
Resistance measuring accuracy: ±(0.1%+1Ω)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Category: Calibrators
Description: Calibrator; pressure,frequency,voltage,current,RTD
Illumination: yes
Related items: POM-5900A/POM; POM-5912B; POM-6173A
Type of device: calibrator
Dimensions: 200x96x47mm
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; set of test leads with alligator clips
Protection: short circuit protection SCP
Measuring instrument features: 24V, 22mA loop supplying; automatic and manual step setting; automatic linear sourcing; measures and sources frequency within 1 cycle/min. to 10kHz range; measures and sources signals simultaneously from 2 channels; measures pressure up to 700 bar using any FLK-700Pxx pressure module; operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP; settings memory
Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage
Current source accuracy: ±(0,025% + 1 digit)
Voltage source accuracy: ±(0,02% + 2 digits)
Measurement: DC current; DC voltage; resistance
Resistance measuring range: 10mΩ...400Ω; 1.5kΩ; 3.2kΩ
DC current measuring range: 0...24mA
DC voltage measuring range: 0...100mV; 0...30V
Ω simulation: 15...3200Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Current source: 0...24mA
Voltage source: 0...20V
DC voltage measuring accuracy: ±(0.02% + 2 digit)
DC current measuring accuracy: ±(0.02% + 2 digit)
Resistance measuring accuracy: ±(0.1%+1Ω)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
товару немає в наявності
В кошику
од. на суму грн.
FLUKE PN648029 |
Виробник: FLUKE
Category: Single Test Leads
Description: Test lead
Type of test accessories: test lead
Related items: FLK-T5-1000
Category: Single Test Leads
Description: Test lead
Type of test accessories: test lead
Related items: FLK-T5-1000
на замовлення 15 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 3927.53 грн |
FLK-TIS55+ 9HZ |
![]() |
Виробник: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 256x192
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 28° horizontal x 20° vertical
Focusing: manual
IP rating: IP54
Dimensions: 267x101x145mm
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable
Three-dimensional resolution: 1.91mrad
Thermal sensitivity (NETD): 40mK
Resistance to: fall from 2m height
Measurement: temperature
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: download from manufacturers website; Fluke Connect
Display resolution: 320x240
Touchpad: yes
Measuring unit: °C; °F
Operating temperature: -10...50°C
Interface: LAN; USB; WiFi
Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 256x192
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 28° horizontal x 20° vertical
Focusing: manual
IP rating: IP54
Dimensions: 267x101x145mm
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable
Three-dimensional resolution: 1.91mrad
Thermal sensitivity (NETD): 40mK
Resistance to: fall from 2m height
Measurement: temperature
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Software: download from manufacturers website; Fluke Connect
Display resolution: 320x240
Touchpad: yes
Measuring unit: °C; °F
Operating temperature: -10...50°C
Interface: LAN; USB; WiFi
Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 228780.29 грн |