Фото | Назва | Виробник | Інформація |
Доступність |
Ціна |
||
---|---|---|---|---|---|---|---|
![]() +3 |
6630-01 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...1MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 |
на замовлення 5 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
6630-03 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...3MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
6630-05 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...5MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 |
на замовлення 2 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
6630-10 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...10MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 |
на замовлення 1 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +3 |
6630-20 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...20MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: LCR meter Measurement time: < 0.003s Measurement accuracy: ±0.05% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +3 |
6630-30 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Measurement frequency: 10Hz...30MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: LCR meter Measurement time: < 0.003s Measurement accuracy: ±0.05% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +3 |
6630-50 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Measurement frequency: 10Hz...50MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: LCR meter Measurement time: < 0.003s Measurement accuracy: ±0.05% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +3 |
6630-01 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...1MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 кількість в упаковці: 1 шт |
на замовлення 5 шт: термін постачання 14-21 дні (днів) |
|
||
![]() +3 |
6630-03 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...3MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 кількість в упаковці: 1 шт |
на замовлення 2 шт: термін постачання 14-21 дні (днів) |
|
||
![]() +3 |
6630-05 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...5MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 кількість в упаковці: 1 шт |
на замовлення 2 шт: термін постачання 14-21 дні (днів) |
|
||
![]() +3 |
6630-10 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Type of meter: LCR meter Kind of display used: LCD TFT 7" Display parameters: 6 digits Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Output impedance: 25Ω; 100Ω Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Standard equipment: mains cable; measuring probe FX-000C19 Measurement time: < 0.003s Measurement accuracy: ±0.05% Operating temperature: 10...40°C Measurement frequency: 10Hz...10MHz Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003 кількість в упаковці: 1 шт |
на замовлення 1 шт: термін постачання 14-21 дні (днів) |
|
||
![]() +3 |
6630-20 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...20MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: LCR meter Measurement time: < 0.003s Measurement accuracy: ±0.05% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +3 |
6630-30 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Measurement frequency: 10Hz...30MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: LCR meter Measurement time: < 0.003s Measurement accuracy: ±0.05% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +3 |
6630-50 | MICROTEST |
![]() ![]() Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480 Kind of display used: LCD TFT 7" Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms Measurement frequency: 10Hz...50MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: LCR meter Measurement time: < 0.003s Measurement accuracy: ±0.05% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-01 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...1MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-01S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...1MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-03 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...3MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-03S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...3MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-05 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...5MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-05S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...5MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-10 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...10MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-10S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...10MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-20 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...20MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-20S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...20MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-30 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...30MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-30S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...30MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-50 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...50MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-50S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...50MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-01 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...1MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-01S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...1MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-03 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...3MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-03S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...3MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-05 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...5MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-05S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...5MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-10 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...10MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-10S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...10MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-20 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...20MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-20S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...20MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-30 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...30MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-30S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...30MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-50 | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...50MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
6632-50S | MICROTEST |
![]() ![]() Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits Kind of display used: LCD TFT 7" Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance Dimensions: 336x147x340mm Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV) Measurement frequency: 10Hz...50MHz Operating temperature: 10...40°C Output impedance: 25Ω; 100Ω Supply voltage frequency: 50/60Hz Supply voltage: 100...240V Display resolution: 800x480 Display parameters: 6 digits Standard equipment: mains cable; measuring probe FX-000C19 Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host Type of meter: impedance analyzer Measurement time: < 0.003s Measurement accuracy: ±0.08% кількість в упаковці: 1 шт |
товару немає в наявності |
В кошику од. на суму грн. | ||
![]() +1 |
7630 | MICROTEST |
![]() ![]() Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS Kind of display used: LCD TFT 4,3" Manufacturer series: MCT-7600 Interface: EXT I/O; Remote; RS232; USB device; USB Host Kind of meter: Hi-Pot Type of meter: safety tester True effective value measurement: True RMS Operating temperature: 5...40°C Test current: 10mA @ 10V AC...5kV AC; 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC Dimensions: 365x145x430mm Rise time: 0.1...10s Measurement time: 0.1...999s Number of chambers: 1 Insulation resistance measuring ranges: 1Ω...12GΩ Supply voltage: 90...264V Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC Test frequency: 50/60Hz Supply voltage frequency: 50/60Hz Display resolution: 480x272 Standard equipment: control pedal F760001; mains cable; test lead x2 Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement |
на замовлення 7 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +1 |
7630 | MICROTEST |
![]() ![]() Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS Kind of display used: LCD TFT 4,3" Manufacturer series: MCT-7600 Interface: EXT I/O; Remote; RS232; USB device; USB Host Kind of meter: Hi-Pot Type of meter: safety tester True effective value measurement: True RMS Operating temperature: 5...40°C Test current: 10mA @ 10V AC...5kV AC; 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC Dimensions: 365x145x430mm Rise time: 0.1...10s Measurement time: 0.1...999s Number of chambers: 1 Insulation resistance measuring ranges: 1Ω...12GΩ Supply voltage: 90...264V Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC Test frequency: 50/60Hz Supply voltage frequency: 50/60Hz Display resolution: 480x272 Standard equipment: control pedal F760001; mains cable; test lead x2 Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement кількість в упаковці: 1 шт |
на замовлення 7 шт: термін постачання 14-21 дні (днів) |
|
||
![]() +1 |
7631 | MICROTEST |
![]() ![]() Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS Kind of display used: LCD TFT 4,3" Manufacturer series: MCT-7600 Interface: EXT I/O; Remote; RS232; USB device; USB Host Kind of meter: Hi-Pot Type of meter: safety tester True effective value measurement: True RMS Operating temperature: 5...40°C Test current: 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC Dimensions: 435x145x500mm Rise time: 0.1...10s Measurement time: 0.1...999s Number of chambers: 8 Insulation resistance measuring ranges: 1Ω...12GΩ Supply voltage: 90...264V Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC Test frequency: 50/60Hz Supply voltage frequency: 50/60Hz Display resolution: 480x272 Standard equipment: control pedal F760001; mains cable; test lead x2 Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement |
на замовлення 3 шт: термін постачання 21-30 дні (днів) |
|
||
![]() +1 |
7631 | MICROTEST |
![]() ![]() Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS Kind of display used: LCD TFT 4,3" Manufacturer series: MCT-7600 Interface: EXT I/O; Remote; RS232; USB device; USB Host Kind of meter: Hi-Pot Type of meter: safety tester True effective value measurement: True RMS Operating temperature: 5...40°C Test current: 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC Dimensions: 435x145x500mm Rise time: 0.1...10s Measurement time: 0.1...999s Number of chambers: 8 Insulation resistance measuring ranges: 1Ω...12GΩ Supply voltage: 90...264V Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC Test frequency: 50/60Hz Supply voltage frequency: 50/60Hz Display resolution: 480x272 Standard equipment: control pedal F760001; mains cable; test lead x2 Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement кількість в упаковці: 1 шт |
на замовлення 3 шт: термін постачання 14-21 дні (днів) |
|
6630-01 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...1MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...1MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
на замовлення 5 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 307146.06 грн |
6630-03 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...3MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...3MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 332049.84 грн |
6630-05 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...5MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...5MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
на замовлення 2 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 371480.89 грн |
6630-10 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...10MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...10MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
на замовлення 1 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 464139.13 грн |
6630-20 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
товару немає в наявності
В кошику
од. на суму грн.
6630-30 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
товару немає в наявності
В кошику
од. на суму грн.
6630-50 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
товару немає в наявності
В кошику
од. на суму грн.
6630-01 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...1MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...1MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
на замовлення 5 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 368575.27 грн |
6630-03 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...3MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...3MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 398459.81 грн |
6630-05 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...5MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...5MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 445777.07 грн |
6630-10 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...10MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Type of meter: LCR meter
Kind of display used: LCD TFT 7"
Display parameters: 6 digits
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Output impedance: 25Ω; 100Ω
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Standard equipment: mains cable; measuring probe FX-000C19
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
Operating temperature: 10...40°C
Measurement frequency: 10Hz...10MHz
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Related items: MCT-AX-PM0004; MCT-F420001; MCT-F420003; MCT-F420005; MCT-F423906A; MCT-FX-0000C7; MCT-FX-0000C9; MCT-FX-000C10; MCT-FX-000C11; MCT-FX-000C12; MCT-FX-000C20; MCT-FX-LR0002; MCT-FX-LR0003
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 556966.95 грн |
6630-20 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6630-30 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6630-50 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: LCR meter; Meas.accur: ±0.05%; LCD TFT 7"; 6 digits; 800x480
Kind of display used: LCD TFT 7"
Measurement: admittance; capacitance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; resistance; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV); ultra-high measuring speed < 3ms
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: LCR meter
Measurement time: < 0.003s
Measurement accuracy: ±0.05%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-01 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-01S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-03 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-03S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-05 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-05S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-10 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-10S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-20 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-20S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-30 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-30S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-50 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-50S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
товару немає в наявності
В кошику
од. на суму грн.
6632-01 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-01S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...1MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-03 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-03S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...3MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-05 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-05S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...5MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-10 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-10S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...10MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-20 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-20S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...20MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-30 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-30S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...30MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-50 |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
6632-50S |
![]() ![]() |
Виробник: MICROTEST
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
Category: LCR Meter
Description: Impedance analyzer; Meas.accur: ±0.08%; LCD TFT 7"; 6 digits
Kind of display used: LCD TFT 7"
Measurement: admittance; conductance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; reactance; relative permeability; relative permittivity; susceptance
Dimensions: 336x147x340mm
Measuring instrument features: 50 sets setting memory; ALC function- Automatic Level Control; auto component classification; BIN comparator function; built-in DC Bias voltage ±12V; cable compensation 0/ 0,5/ 1/ 2 m; displays up to 4 component parameters; Equivalent Circuit Analysis; open circuit/short circuit/load correction function; parallel or serial measurement; Test Signal Current Level 200μA-20mArms (resolution: 10μA); Test Signal Voltage Level 10mV-2Vrms (resolution: 1mV)
Measurement frequency: 10Hz...50MHz
Operating temperature: 10...40°C
Output impedance: 25Ω; 100Ω
Supply voltage frequency: 50/60Hz
Supply voltage: 100...240V
Display resolution: 800x480
Display parameters: 6 digits
Standard equipment: mains cable; measuring probe FX-000C19
Interface: GPIB; HANDLER I/O; LAN; RS232; USB device; USB Host
Type of meter: impedance analyzer
Measurement time: < 0.003s
Measurement accuracy: ±0.08%
кількість в упаковці: 1 шт
товару немає в наявності
В кошику
од. на суму грн.
7630 |
![]() ![]() |
Виробник: MICROTEST
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V AC...5kV AC; 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 365x145x430mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 1
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V AC...5kV AC; 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 365x145x430mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 1
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
на замовлення 7 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 117399.81 грн |
7630 |
![]() ![]() |
Виробник: MICROTEST
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V AC...5kV AC; 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 365x145x430mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 1
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
кількість в упаковці: 1 шт
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V AC...5kV AC; 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 365x145x430mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 1
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
кількість в упаковці: 1 шт
на замовлення 7 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 140879.77 грн |
7631 |
![]() ![]() |
Виробник: MICROTEST
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 435x145x500mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 8
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 435x145x500mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 8
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
на замовлення 3 шт:
термін постачання 21-30 дні (днів)Кількість | Ціна |
---|---|
1+ | 255877.03 грн |
7631 |
![]() ![]() |
Виробник: MICROTEST
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 435x145x500mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 8
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
кількість в упаковці: 1 шт
Category: Electrical Safety Testers
Description: Safety tester; 1Ω÷12GΩ; Utest: 10÷5000VAC,10÷6000VDC; True RMS
Kind of display used: LCD TFT 4,3"
Manufacturer series: MCT-7600
Interface: EXT I/O; Remote; RS232; USB device; USB Host
Kind of meter: Hi-Pot
Type of meter: safety tester
True effective value measurement: True RMS
Operating temperature: 5...40°C
Test current: 10mA @ 10V DC...6kV DC; 30mA @ 10V AC...5kV AC
Dimensions: 435x145x500mm
Rise time: 0.1...10s
Measurement time: 0.1...999s
Number of chambers: 8
Insulation resistance measuring ranges: 1Ω...12GΩ
Supply voltage: 90...264V
Test voltage: 10... 1000V DC; 10...5000V AC; 10...6000V DC
Test frequency: 50/60Hz
Supply voltage frequency: 50/60Hz
Display resolution: 480x272
Standard equipment: control pedal F760001; mains cable; test lead x2
Measuring instrument features: 30 sets setting memory; ARC (Arcing detection)- Transient detection; insulation resistance test 100-500V, 1-1000MΩ (±5%); 500-1000V, 2-12000MΩ (±5%); Key-Lock function; manual and automated tests; remote control; safety interlock function; True RMS measurement
кількість в упаковці: 1 шт
на замовлення 3 шт:
термін постачання 14-21 дні (днів)Кількість | Ціна |
---|---|
1+ | 307052.43 грн |